Loading...
HomeMy WebLinkAboutCASEY'S GENERAL STORE #2880 - 3260 UNIVERSITY AVENUE OF W A 7.F INVOICE DATE DUE DATE INVOICE# TOTAL DUE _�0 08/12/2026 09/16/2026 2027-00000063 $80.00 • •uI 1■it III II•111 • S 7 V 1/‘5 Customer#: 14657 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable CASEY'S GENERAL STORE-UNIVERSITY 715 Mulberry St 1 SE CONVENIENCE BLVD WATERLOO, IA 50703 ANKENY, IA 50021 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-3260 UNIVERSITY AVE- FOR BILLING INQUIRY: (319)291-4323 08/04/26 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 14657 08/12/2026 09/16/2026 2027-00000063 $80.00 Less Prepayment $0.00 Total Due-* $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 425 E.3rd Street dkup Casey's General Store#2880-1604 La Porte RD,BLDG 1604 La Porte Rd,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 0810412026 Annual Inspection(1Yr) /41666 e.t 17583 Lead Inspector Shift Station Unit BRAD BALDWIN NIA N/A N/A Other Inspectors N/A SUMMARY OF INSPECTION 0 41 ® 10 ® 29 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 08/26/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-08/0512026 @ 15:50 •$80 annual inspection fee BRAD BALDWIN-08105/2026 @ 15:51 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-08/0512026 @ 15:51 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-08/0512026 @ 15:51 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signatureedpost Report completed post inspection Jennifer Iburg Date: BRAD BALDWIN 08/05/2026 CHECKLISTS GENERATED ON 8/5/26, 3:57 PM 1 of 6 Additional Codes Sta>us Code Description Fail 1010.2.4-Locks and latches. Ux Locks and latches shall be permitted to prevent operation of Location:Front exit door doors where any of the following exist:1.Places of detention Comments:Install signage compliant to code''THIS DOOR TO or restraint.2,ln Group I-1,Condition 2 and Group 1-2 REMAIN UNLOCKED DURING BUSINESS HOURS"on interior of occupancies where the clinical needs of persons receiving doors in approved location. care require containment or where persons receiving care pose a security threat,provided that all clinical staff can readily unlock doors at all times,and all such locks are keyed to keys carried by all clinical staff at all times or all clinical staff have the codes or other means necessary to operate the locks at all times.2.3.In buildings in occupancy Group A having an occupant load of 300 or less,Groups B,F,M and S, and in places of religious worship,the main door or doors are permitted to be equipped with key-operated locking devices from the egress side provided:2.1.3.1.The locking device is readily distinguishable as locked.2.2.3.2.A readily visible durable sign is posted on the egress side on or adjacent to the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch (25 mm)high on a contrasting background.2.3.3.3.The use of the key-operated locking device is revocable by the fire code official for due cause.3.4.Where egress doors are used in pairs,approved automatic flush bolts shall be permitted to be used,provided that the door leaf having the automatic flush bolts does not have a doorknob or surface-mounted hardware.4.5.Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch,dead bolt or security chain,provided such devices are openable from the inside without the use of a key or tool.5.6.Fire doors after the minimum elevated temperature has disabled the unlatching mechanism in accordance with listed fire door test procedures.6.7.Doors serving roofs not intended to be occupied shall be permitted to be locked,preventing entry to the building from the roof.8.Other than egress courts,where occupants must egress from an exterior space through the building for means of egress,exit access doors shall be permitted to be equipped with an approved locking device where installed and operated in accordance with all of the following:8.1.The maximum occupant load shall be posted where required by Section 1004.9.Such sign shall be permanently affixed inside the building and shall be posted in a conspicuous space near all the exit access doorways.8.2.A weatherproof telephone or two-way communication system installed in accordance with Sections 1009.8.1 and 1009.8.2 shall be located adjacent to not less than one required exit access door on the exterior side.8.3.The egress door locking device is readily distinguishable as locked and shall be a key- operated locking device.8.4.A clear window or glazed door opening,not less than 5 square feet(0.46 m2)in area,shall be provided at each exit access door to determine if there are occupants using the outdoor area.8.5.A readily visible durable sign shall be posted on the interior side on or adjacent to each locked required exit access door serving the exterior area stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on the sign shall be not less than 1 inch(25.4 mm)high on a contrasting background.8.6.The occupant load of the occupied exterior area shall not exceed 300 occupants in accordance with Section 1004.9.Locking devices are permitted on doors to balconies,decks or other exterior spaces serving individual dwelling or sleeping units. 10.Locking devices are permitted on doors to balconies, decks or other exterior spaces of 250 square feet(23.23 m2)or less,serving a private office space. GENERATED ON 8/5/26, 3:57 PM 2 OF 6 Fall 102.4-Application of building code. 0 The design and construction of new structures shall comply Location:Water heater with the International Building Code,and any alterations, Comments:Licensed contractor shall obtain permit and inspection additions,changes in use or changes in structures required for water heater installed without permit. by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. •...ICµ CCL,11.4C,OA3 • �miiumu�, j fi! .q. r.,,,,,,..3 Fail 102.4-Application of building code. The design and construction of new structures shall comply Location:Used cooking oil storage tank with the International Building Code,and any alterations, Comments:Licensed electrical contractor shall obtain permit and additions,changes in use or changes in structures required inspection for receptacle added without permit. by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. Fail 5303.5.3-Securing compressed gas containers,cylinders Oand tanks. Location:Electric room Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders with chain to avoid tip secured to prevent falling caused by contact,vibration or over. seismic activity.Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the I movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. GENERATED ON 8/5/26, 3:57 PM 3 OF 6 • Fail 5303.5.3-Securing compressed gas containers,cylinders Oand tanks. Location:Water heater room Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders with chain to avoid tip secured to prevent falling caused by contact,vibration or over. seismic activity.Securing of compressed gas containers, cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the { movement of compressed gas containers,cylinders or tanks. 3.Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers' warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress. 4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use.Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. General Housekeeping Stasis Code Description Fail 304.3.1-Spontaneous ignition. Materials susceptible to spontaneous ignition,such as oily Location:Kitchen rags,shall be stored in a listed disposal container.Contents Comments:Provide listed container with self closing lid for disposal of such containers shall be removed and disposed of daily. of soiled rags.Rags and towels soiled with fats,oils or grease shall not be disposed of in the trash. • - � GENERATED ON 8/5/26, 3:57 PM 4 OF 6 Electrical Safety Stews Code Description Fail 603.2.2-Unapproved conditionsOpen electrical terminations. OOpen junction boxes and open-wiring splices shall be Location:Exterior outlets(2)next to Ice Freezer prohibited.Approved covers shall be provided for all switch Comments:Replacing missing weather rated outlet covers. and electrical outlet boxes. Fail 603.6-Extension cords. 0 Extension cords and flexible cordsshall not be a substitute Location:Ice cream freezer near front exit for permanent wiring and shall be listed and labeled in Comments:Remove extension cord plugged to freezer.Appliance accordance with UL 817.Extension cords and flexible shall plug directly to a permanent outlet,extension cords shall not be cordsshall not be affixed to structures,extended through used as permanent wiring. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. aJx Extension cords and flexible cordsshall not be a substitute Location:Cabinet below Tea dispensing machines for permanent wiring and shall be listed and labeled in Comments:Remove red extension cord inside cabinet accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Commercial Cooking Hood Suppression System Stawc Code Description Fail 904.13.5.2-Extinguishing system service. Automatic fire-extinguishing systems shall be serviced not Location:Kitchen hood suppression system less frequently than every six months and after activation of Comments:All suppression head covers shall be on covering heads the system.Inspection shall be by qualified individuals,and a to avoid grease/debris accumulation on heads.Currently,covers off certificate of inspection shall be forwarded to the fire code of heads above fryers and conveyor oven official upon completion. GENERATED ON 8/5/26, 3:57 PM 5 OF 6 Eo Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 8/5/26, 3:57 PM 6 OF 6