COMMERCIAL FIRE INSPECTION-3260 UNIVERSITY AVE- FOR BILLING INQUIRY: (319)291-4323
08/04/26
Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
14657 08/12/2026 09/16/2026 2027-00000063 $80.00
Less Prepayment $0.00
Total Due-* $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue
Inspection Report
425 E.3rd Street
dkup Casey's General Store#2880-1604 La Porte RD,BLDG 1604 La Porte Rd,Waterloo
IA 50702
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
0810412026 Annual Inspection(1Yr) /41666 e.t 17583
Lead Inspector Shift Station Unit
BRAD BALDWIN NIA N/A N/A
Other Inspectors
N/A
SUMMARY OF INSPECTION
0 41 ® 10 ® 29
Passed codes Failed codes N/A codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
BRAD BALDWIN
08/26/2026
brad.baldwin@waterloo-ia.org,3192914319
GENERAL NOTES
BRAD BALDWIN-08/0512026 @ 15:50
•$80 annual inspection fee
BRAD BALDWIN-08105/2026 @ 15:51
•Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224
BRAD BALDWIN-08/0512026 @ 15:51
•Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards
corrected
BRAD BALDWIN-08/0512026 @ 15:51
•If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for
inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re-
inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.
SIGNATURES
Contact signature Inspector signature
No signatureedpost
Report completed post inspection
Jennifer Iburg Date: BRAD BALDWIN 08/05/2026
CHECKLISTS
GENERATED ON 8/5/26, 3:57 PM 1 of 6
Additional Codes
Sta>us Code Description
Fail 1010.2.4-Locks and latches.
Ux Locks and latches shall be permitted to prevent operation of Location:Front exit door
doors where any of the following exist:1.Places of detention Comments:Install signage compliant to code''THIS DOOR TO
or restraint.2,ln Group I-1,Condition 2 and Group 1-2 REMAIN UNLOCKED DURING BUSINESS HOURS"on interior of
occupancies where the clinical needs of persons receiving doors in approved location.
care require containment or where persons receiving care
pose a security threat,provided that all clinical staff can
readily unlock doors at all times,and all such locks are keyed
to keys carried by all clinical staff at all times or all clinical
staff have the codes or other means necessary to operate the
locks at all times.2.3.In buildings in occupancy Group A
having an occupant load of 300 or less,Groups B,F,M and S,
and in places of religious worship,the main door or doors are
permitted to be equipped with key-operated locking devices
from the egress side provided:2.1.3.1.The locking device is
readily distinguishable as locked.2.2.3.2.A readily visible
durable sign is posted on the egress side on or adjacent to
the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN
THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch
(25 mm)high on a contrasting background.2.3.3.3.The use
of the key-operated locking device is revocable by the fire
code official for due cause.3.4.Where egress doors are used
in pairs,approved automatic flush bolts shall be permitted to
be used,provided that the door leaf having the automatic
flush bolts does not have a doorknob or surface-mounted
hardware.4.5.Doors from individual dwelling or sleeping
units of Group R occupancies having an occupant load of 10
or less are permitted to be equipped with a night latch,dead
bolt or security chain,provided such devices are openable
from the inside without the use of a key or tool.5.6.Fire
doors after the minimum elevated temperature has disabled
the unlatching mechanism in accordance with listed fire door
test procedures.6.7.Doors serving roofs not intended to be
occupied shall be permitted to be locked,preventing entry to
the building from the roof.8.Other than egress courts,where
occupants must egress from an exterior space through the
building for means of egress,exit access doors shall be
permitted to be equipped with an approved locking device
where installed and operated in accordance with all of the
following:8.1.The maximum occupant load shall be posted
where required by Section 1004.9.Such sign shall be
permanently affixed inside the building and shall be posted in
a conspicuous space near all the exit access doorways.8.2.A
weatherproof telephone or two-way communication system
installed in accordance with Sections 1009.8.1 and 1009.8.2
shall be located adjacent to not less than one required exit
access door on the exterior side.8.3.The egress door locking
device is readily distinguishable as locked and shall be a key-
operated locking device.8.4.A clear window or glazed door
opening,not less than 5 square feet(0.46 m2)in area,shall
be provided at each exit access door to determine if there are
occupants using the outdoor area.8.5.A readily visible
durable sign shall be posted on the interior side on or
adjacent to each locked required exit access door serving the
exterior area stating:"THIS DOOR TO REMAIN UNLOCKED
WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on
the sign shall be not less than 1 inch(25.4 mm)high on a
contrasting background.8.6.The occupant load of the
occupied exterior area shall not exceed 300 occupants in
accordance with Section 1004.9.Locking devices are
permitted on doors to balconies,decks or other exterior
spaces serving individual dwelling or sleeping units.
10.Locking devices are permitted on doors to balconies,
decks or other exterior spaces of 250 square feet(23.23
m2)or less,serving a private office space.
GENERATED ON 8/5/26, 3:57 PM 2 OF 6
Fall 102.4-Application of building code.
0 The design and construction of new structures shall comply Location:Water heater
with the International Building Code,and any alterations, Comments:Licensed contractor shall obtain permit and inspection
additions,changes in use or changes in structures required for water heater installed without permit.
by this code,which are within the scope of the International
Building Code,shall be made in accordance therewith.
•...ICµ CCL,11.4C,OA3
•
�miiumu�,
j fi!
.q.
r.,,,,,,..3
Fail 102.4-Application of building code.
The design and construction of new structures shall comply Location:Used cooking oil storage tank
with the International Building Code,and any alterations, Comments:Licensed electrical contractor shall obtain permit and
additions,changes in use or changes in structures required inspection for receptacle added without permit.
by this code,which are within the scope of the International
Building Code,shall be made in accordance therewith.
Fail 5303.5.3-Securing compressed gas containers,cylinders
Oand tanks. Location:Electric room
Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders with chain to avoid tip
secured to prevent falling caused by contact,vibration or over.
seismic activity.Securing of compressed gas containers,
cylinders and tanks shall be by one of the following methods:
1.Securing containers,cylinders and tanks to a fixed object
with one or more restraints.2.Securing containers,cylinders
and tanks on a cart or other mobile device designed for the
I movement of compressed gas containers,cylinders or tanks.
3.Nesting of compressed gas containers,cylinders and tanks
at container filling or servicing facilities or in sellers'
warehouses not open to the public.Nesting shall be allowed
provided that the nested containers,cylinders or tanks,if
dislodged,do not obstruct the required means of egress.
4.Securing of compressed gas containers,cylinders and
tanks to or within a rack,framework,cabinet or similar
assembly designed for such use.Exception:Compressed gas
containers,cylinders and tanks in the process of
examination,filling,transport or servicing.
GENERATED ON 8/5/26, 3:57 PM 3 OF 6
•
Fail 5303.5.3-Securing compressed gas containers,cylinders
Oand tanks. Location:Water heater room
Compressed gas containers,cylinders and tanks shall be Comments:Secure compressed gas cylinders with chain to avoid tip
secured to prevent falling caused by contact,vibration or over.
seismic activity.Securing of compressed gas containers,
cylinders and tanks shall be by one of the following methods:
1.Securing containers,cylinders and tanks to a fixed object
with one or more restraints.2.Securing containers,cylinders
and tanks on a cart or other mobile device designed for the
{ movement of compressed gas containers,cylinders or tanks.
3.Nesting of compressed gas containers,cylinders and tanks
at container filling or servicing facilities or in sellers'
warehouses not open to the public.Nesting shall be allowed
provided that the nested containers,cylinders or tanks,if
dislodged,do not obstruct the required means of egress.
4.Securing of compressed gas containers,cylinders and
tanks to or within a rack,framework,cabinet or similar
assembly designed for such use.Exception:Compressed gas
containers,cylinders and tanks in the process of
examination,filling,transport or servicing.
General Housekeeping
Stasis Code Description
Fail 304.3.1-Spontaneous ignition.
Materials susceptible to spontaneous ignition,such as oily Location:Kitchen
rags,shall be stored in a listed disposal container.Contents
Comments:Provide listed container with self closing lid for disposal
of such containers shall be removed and disposed of daily. of soiled rags.Rags and towels soiled with fats,oils or grease shall
not be disposed of in the trash.
•
- �
GENERATED ON 8/5/26, 3:57 PM
4 OF 6
Electrical Safety
Stews Code Description
Fail 603.2.2-Unapproved conditionsOpen electrical terminations.
OOpen junction boxes and open-wiring splices shall be Location:Exterior outlets(2)next to Ice Freezer
prohibited.Approved covers shall be provided for all switch Comments:Replacing missing weather rated outlet covers.
and electrical outlet boxes.
Fail 603.6-Extension cords.
0 Extension cords and flexible cordsshall not be a substitute Location:Ice cream freezer near front exit
for permanent wiring and shall be listed and labeled in Comments:Remove extension cord plugged to freezer.Appliance
accordance with UL 817.Extension cords and flexible shall plug directly to a permanent outlet,extension cords shall not be
cordsshall not be affixed to structures,extended through
used as permanent wiring.
walls,ceilings or floors,or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
Fail 603.6-Extension cords.
aJx Extension cords and flexible cordsshall not be a substitute Location:Cabinet below Tea dispensing machines
for permanent wiring and shall be listed and labeled in
Comments:Remove red extension cord inside cabinet
accordance with UL 817.Extension cords and flexible
cordsshall not be affixed to structures,extended through
walls,ceilings or floors,or under doors or floor coverings,
nor shall such cords be subject to environmental damage or
physical impact.Extension cords shall be used only with
portable appliances.Extension cords marked for indoor use
shall not be used outdoors.
Commercial Cooking Hood Suppression System
Stawc Code Description
Fail 904.13.5.2-Extinguishing system service.
Automatic fire-extinguishing systems shall be serviced not Location:Kitchen hood suppression system
less frequently than every six months and after activation of
Comments:All suppression head covers shall be on covering heads
the system.Inspection shall be by qualified individuals,and a to avoid grease/debris accumulation on heads.Currently,covers off
certificate of inspection shall be forwarded to the fire code of heads above fryers and conveyor oven
official upon completion.
GENERATED ON 8/5/26, 3:57 PM
5 OF 6
Eo Statement of Fees
FEE
Invoice Date Inspection Fee Date Paid Amount Paid
NIA $80.00
Invoice Number Check Number Transaction Number
NIA NIA NIA
GENERATED ON 8/5/26, 3:57 PM
6 OF 6