Loading...
HomeMy WebLinkAboutMCDONALDS RESTAURANT - 2222 LOGAN AVENUE ©� WA 7. INVOICE DATE DUE DATE INVOICE# TOTAL DUE A•V 08/12/2026 09/16/2026 2027-00000070 $80.00 „rive.. O • 11 1■11 11 11 11 • > T- T O 67v11‘' Customer#: 25025 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable MCDONALDS RESTAURANT(Location 3695 715 Mulberry St University Av) WATERLOO, IA 50703 1010 S. GRAND AVENUE CHARLES CITY,IA 50616 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-2222 LOGAN AVE-07/28/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 25025 08/12/2026 09/16/2026 2027-00000070 $80.00 Less Prepayment $0.00 Total Due -* $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue tc l Inspection Report 425 E.3rd Street McDonalds-2222 Logan AVE,BLDG 2222 Logan Ave,Waterloo IA 50703 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 07128/2026 Annual Inspection(1Yr) S6b)1/45- 8865 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA N/A Other Inspectors NIA SUMMARY OF INSPECTION 0 43 G 12 0 27 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 0813112026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-07131/2026 @ 10:31 •$80 annual inspection fee BRAD BALDWIN-07131/2026 @ 10:31 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-07131/2026 @ 10:31 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Scott Soifer Date: BRAD BALDWIN 07/31/2026 CHECKLISTS Emergency Equipment S= 5 Code Description Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Kitchen-Back exit in Section 1013.6,3.The system shall be capable of powering Comments:Repair or replace exit sign that failed to illuminate during the required load for a duration of not less than 90 minutes. test GENERATED ON 7/31/26, 10:34 AM 1 OF 8 Additional Codes 5[atus Coae Description Fail 603.1-General. Electrical equipment,wiring and systems required by this Location:Kitchen-Near icemaker code or the International Building Code shall be installed, Comments:White cord(see attachment)plugged to power strip shall used and maintained in accordance with NFPA 70 and not extend through a concealed area including through walls,floors Sections 603.2 through 603.10. and above drop ceilings.Currently extending above drop ceiling IP is Fail 603.1-General. Electrical equipment,wiring and systems required by this Location:Kitchen-Above bun toaster code or the International Building Code shall be installed, Comments:Flexible supply cords shall not extend through a used and maintained in accordance with NFPA 70 and concealed area including through walls,floors and above drop Sections 603.2 through 603.10. ceilings. .1144 .. GENERATED ON 7/31/26, 10:34 AM 2 OF 8 Fail 603.1-General. Electrical equipment,wiring and systems required by this Location:Kitchen-"Fresh Cooking Oil"tank code or the International Building Code shall be installed, Comments:Flexible supply cords shall not extend through a used and maintained in accordance with NFPA 70 and concealed area including through walls,floors and above drop Sections 603.2 through 603.10. ceilings. b r is ii„ fit PP :t A\ `€ram` 4 Fail 603,1-General. Electrical equipment,wiring and systems required by this Location:Kitchen-Above CO2 rack code or the International Building Code shall be installed, Comments:Flexible supply cords(yellow cord)shall not extend used and maintained in accordance with NFPA 70 and through a concealed area including through walls,floors and above Sections 603.2 through 603.10. drop ceilings. Ars - .:E....ii>"_._\„...14 1 0..\.\:- 0 , : . , i t4.-.0,---,---:----,, • ± , 4. \ • .. ;.._,.,..., , .. _ • . . , GENEPATED ON 7/21/26, 10:34 AM 3 OF 8 Fail 603.1-General. Electrical equipment,wiring and systems required by this Location:Kitchen office code or the International Building Code shall be installed, Comments:Flexible supply cords shall not extend through a used and maintained in accordance with NFPA 70 and concealed area including through walls,floors and above drop Sections 603.2 through 603.10. ceilings. Ilk,, 1 , )10 ,,,,,,,,;. ....,-,,‘,\ -- .„,"• .•'� f y,r,),;, ,•—._. ,F.F 5 A ,, ,:,/, ,,:., ii , .... . ... _ ,, . ,...,.....„..... , , . ..„...._ .. . (., „!.. .... ...... .. __A._ ,, n u .,.., ,I .,.. i„.. s r la, Fail 603.1-General. Electrical equipment,wiring and systems required by this Location:TV outside of kitchen office code or the International Building Code shall be installed, Comments:Flexible supply cords shall not extend through a used and maintained in accordance with NFPA 70 and concealed area including through walls,floors and above drop Sections 603.2 through 603.10. ceilings. Fail 603.1-General. Electrical equipment,wiring and systems required by this Location:Kitchen-"Used cooking Oil"tank code or the International Building Code shall be installed, Comments:Flexible supply cords shall not extend through a used and maintained in accordance with NFPA 70 and concealed area including through walls,floors and above drop Sections 603.2 through 603.10. ceilings. GENERATED ON 7/31/26, 10:34 AM 4 OF 8 Fail 603.1.1-Equipment and fixtureswiring. Electrical equipment and fixtures All electrical equipment, Location:Dishwasher wiring,devices and appliances shall be tested;and listed by Comments:Appliance supply cord missing protection entering box an approved agency and labeled;and installed,used and shall be corrected. maintained in accordance with NFPA 70 and all instructions included as part of such listing. s o� Air �dGy GENERATED ON 7/37./26, 1O:34 AM 5 OF 8 Electrical Safety Saws Code Description Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Kitchen near back exit door prohibited.Approved covers shall be provided for all switch Comments:Cover hanging(see attached)exposing wire connections and electrical outlet boxes, shall be corrected pi \ V. ' I i A a Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Kitchen-Drive thru window prohibited.Approved covers shall be provided for all switch Comments:Wires shall be properly capped and cover on box and electrical outlet boxes. installed. Dtm L ', GENERATED ON 7/31/26, 16:34 AM 6 OF 8 Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:Kitchen office-Behind IT Rack �J ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip shall be properly supported to avoid hanging to environmental or physical damage. by wires. . iip 0 Ilk 3 9 LSs,L, ;4-4k . , , - ' .� 7 j1 GENERATED ON 7/31/26, 10:34 AM 7 OF 8 E'o Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 7/31/26, 10:34 AM 8 OF 8