Loading...
HomeMy WebLinkAboutROME'S PLACE - 201 RATH STREET OF W A y. INVOICE DATE DUE DATE INVOICE# TOTAL DUE ( 08/12/2026 09/16/2026 2027-00000072 $80.00 ,,roars' , • ) O 3S• t/1 3 Customer#: 24755 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ROME'S PLACE 715 Mulberry St 201 RATH ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 201 RATH ST-08/04/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24755 08/12/2026 09/16/2026 2027-00000072 $80.00 Less Prepayment $0.00 Total Due—* $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. a,.,„,, Waterloo Fire Rescue 1 Inspection Report 425 E.3rd Street Rome's Place-201 Rath ST,BLDG 201 Rath St,Waterloo IA 50703 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 0810412026 Annual Inspection(1Yr) 44i 7 S5 j j;- 17362 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION 0 36 L 25 ® 27 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 08/26/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-08105/2026 @ 14:51 •$80 annual inspection fee BRAD BALDWIN-08/05/2026 @ 14:51 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-08105/2026 @ 14:51 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-08/0512026 @ 14:51 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-08/05/2026 @ 14:52 Hood exhaust suppression system due for required inspection on 9120126. SIGNATURES Contact signature Inspector signature No signature post i `",`7 i'�j Report completed post inspection -11 �,11 C� Rome Mabry(2025) Date: BRAD BALDWIN 08105/2026 CHECKLISTS GENERATED ON 8/5/26, 3:27 PM 1 OF 12 Means of Egress Status Code Description Fail 1010.2.5-Bolt locks. Manually operated flush bolts or surface bolts are not Location:South exit door permitted.Exceptions:1.On doors not required for egress in Comments:Remove slide bolt lock from door immediately. individual dwelling units or sleeping units.2.Where a pair of doors serves a storage or equipment room,manually operated edge-or surface-mounted bolts are permitted on the inactive leaf.3.Where a pair of doors serves an occupant load of less than 50 persons in a Group B,F or S occupancy, manually operated edge-or surface-mounted bolts are permitted on the inactive leaf.The inactive leaf shall not contain doorknobs,panic bars or similar operating hardware. 4.Where a pair of doors serves a Group B,F or S occupancy, manually operated edge-or surface-mounted bolts are permitted on the inactive leaf provided that such inactive leaf is not needed to meet egress capacity requirements and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1.The inactive leaf shall not contain doorknobs,panic bars or similar operating hardware.5.Where a pair of doors serves patient care rooms in Group 1-2 occupancies,self-latching edge-or surface- mounted bolts are permitted on the inactive leaf provided that the inactive leaf is not needed to meet egress capacity requirements and the inactive leaf shall not contain doorknobs,panic bars or similar operating hardware. • I! 11 CAUTION • imiLZ ATCFI Fail 1032.2-Reliability. ORequired exit accesses,exits and exit discharges shall be Location:South exit door continuously maintained free from obstructions or Comments:Remove yellow chain from doorway impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. GENERATED ON 8/5/26, 3:27 PM 2 OF 12 Additional Codes Status Code Description Fail 102.4-Application of building code. 0 The design and construction of new structures shall comply Location:Electric permit(mini-splits) with the International Building Code,and any alterations, Comments:Licensed contractor(Custom Electrical Services)shall additions,changes in use or changes in structures required obtain inspection of permit for(3)new mini splits installed. by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. Fail 603.1.1-Equipment and fixtureswiring. OElectrical equipment and fixtures All electrical equipment, Location:Mini splits(3) wiring,devices and appliances shall be tested;and listed by Comments:Provide documentation of proper listing of Mini Splits an approved agency and labeled;and installed,used and (x3)equipment installed.Equipment shall be properly installed per its maintained in accordance with NFPA 70 and all instructions listing. included as part of such listing. Fail 603.1.1-Equipment and fixtureswiring. V Electrical equipment and fixtures All electrical equipment, Location:Chest freezer near bar. wiring,devices and appliances shall be tested;and listed by Comments:Appliances including heating elements or motors shall an approved agency and labeled;and installed,used and plug directlyto permanent outlet.Currentlyfreezer plugged maintained in accordance with NFPA 70 and all instructions p g p rip to a power strip that is hanging by wires.Remove power strip to included as part of such listing. appliance. Fail 603.1.1-Equipment and fixtureswiring. 0 Electrical equipment and fixtures All electrical equipment, Location:South window LED lights wiring,devices and appliances shall be tested;and listed by Comments:provide documentation of listing of LED lighting.Lighting an approved agency and labeled;and installed,used and shall be properly listed and used properly accordingly to its listing. maintained in accordance with NFPA 70 and all instructions included as part of such listing. Fail 606.2-Where required. OA Type I hood shall be installed at or above all commercial Location:Kitchen cooking equipment cooking appliances and domestic cooking appliances used Comments:Relocate cooking equipment roducit g grease laden for commercial purposes that produce grease vapors. vapors to be within 6 inches inside of outer edges of hood exhaust Exceptions:1.Factory-built commercial exhaust hoods that system to avoid flame rollout.Appliances currently outside of hood are listed and labeled in accordance with UL 710,and coverage. installed in accordance with Section 304.1 of the International Mechanical Code,shall not be required to comply with Sections 507.1.5,507.2.3,507.2.5,507.2.8,507.3.1,507.3.3, 507.4 and 507.5 of the International Mechanical Code. 2.Factory-built commercial cooking recirculating systems that are listed and labeled in accordance with UL 710B,and installed in accordance with Section 304.1 of the International Mechanical Code,shall not be required to comply with Sections 507.1.5,507.2.3,507.2.5,507.2.8,507.3.1,507.3.3, 507.4 and 507.5 of the International Mechanical Code.Spaces in which such systems are located shall be considered to be kitchens and shall be ventilated in accordance with Table 403.3.1.1 of the International Mechanical Code.For the purpose of determining the floor area required to be ventilated,each individual appliance shall be considered as occupying not less than 100 square feet(9.3 m2).3.Where cooking appliances are equipped with integral down-draft exhaust systems and such appliances and exhaust systems are listed and labeled for the application in accordance with NFPA 96,a hood shall not be required at or above them.4.A Type I hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mg1m3 or less of grease when tested at an exhaust flow rate of 500 cfm(0.236 m3/s)in accordance with UL 710B. GENERATED ON 8/5/26, 3:27 PM 3 OF 12 General Housekeeping Status Code Description Fail 304.3.1-Spontaneous ignition. Ux Materials susceptible to spontaneous ignition,such as oily Location:Kitchen rags,shall be stored in a listed disposal Container.Contents Comments:Provide listed container with self closing lid for disposal of such containers shall be removed and disposed of daily, of soiled rag and towels.Soiled rags containing fats,oils or grease shall be disposed of in container and removed from building daily 01111 GENERATED ON 8/5/26, 3:27 PM 4 OF 12 Electrical Safety Status Code Description Fail 603.2-Abatement of unsafe conditions and electrical hazards. Location:Men's bathroom Identified electrical hazards shall be abated.Identified Comments:Light switch cover currently taped on,cover shall be hazardous electrical conditions in permanent wiring shall be installed properly as manufactured. brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Office prohibited.Approved covers shall be provided for all switch Comments:Install blank covering in panel opening to avoid shock and electrical outlet boxes. hazard. t , e t' :i s. 1\ t 4 , omret 't. W �tr tro Fail 603.5.2-Application and usePower supply. Relocatable power taps and current taps shall be directly Location:Music machines&ATM connected to a permanently installed receptacle.Exceptions: Comments:Power strips shall plug directly to a permanent outlet. 1.Where approved for use in a Group A occupancy or in a Currently daisy chained to another power strip is prohibited. meeting room in a Group B occupancy,not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. GENERATED ON 8/5/26, 3:27 PM 5 OF 12 Pail 603.5.2-Application and usePower supply. ORelocatable power taps and current taps shall be directly Location:DJ Booth connected to a permanently installed receptacle.Exceptions: Comments:Power strip on counter currently daisy chained to 1.Where approved for use in a Group A occupancy or in a another power strip is prohibited.Power strips shall plug directly to a meeting room in a Group B occupancy,not more than five permanent outlet, relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. i o4,4 J GENERATED ON 8/5/26, 3;27 PM 6 OF 12 Fall 603.5.2-Application and usePower supply. ORelocatable power taps and current taps shall be directly Location:Office connected to a permanently installed receptacle.Exceptions: Comments:REPEAT VIOLATION:Multiple daisy chained power strips i.Where approved for use in a Group A occupancy or in a is prohibited.Each power strip shall plug directly to a permanent meeting room in a Group B occupancy,not more than five outlet.Also,power strips shall be properly supportedlmounted to relocatable power taps shall be permitted to be connected avoid hanging by wires together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. 1 L%, t ' \ \ .0.0,0° '"/jI ....0010 - Iwo,- -..z...444 - alio. ''''' V Os\g, i ..&... .,4 4 , ti fir. , Fail 603.5.3-Installation. 0 Relocatable power tap cords shall not extend through walls, Location:Behind hostess stand at South exit door ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip shall be properly supportedlmounted to to environmental or physical damage. avoid hanging by wires. y I - ‘, Ni„,,,,. ):A- 11 i 1 GENERATED ON 8/5/26, 3:27 PM 7 OF 12 Fail 603.6.3-Installation, Relocatable power tap cords shall not extend through walls, Location:Speaker podium near hostess stand ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip shall be properly supported/mounted to to environmental or physical damage. avoid hanging by wires. >1 Y x f' ' x. .0:: ! 4/ii , -,„ 3 t Fail 603.5.3-Installation. ORelocatable power tap cords shall not extend through walls, Location:Behind music machines&ATM ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip shall be properly supportedlmounted to to environmental or physical damage. avoid hanging by wires. Fail 603.5.3-Installation. Cx Relocatable power tap cords shall not extend through walls, Location:Bar-near"Miller High Life"sign ceilings,floors,under doors or floor coverings,or be subject Comments:Power stripshall be properly supportedlmounted to environmental or physical damage. p p Y to avoid hanging by wires. k ".". ,.ski: i t, GENERATED ON 8/5/26, 3:27 PM 8 OF 12 Fail 603.5.3-installation. O Relocatable power tap cords shall not extend through walls, Location:DJ Booth ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip below counter shall be properly to environmental or physical damage. supported/mounted to avoid hanging by wires. Fail 603.6-Extension cords. OExtension cords and flexible cordsshall not be a substitute Location:Bar for permanent wiring and shall be listed and labeled in Comments:Remove extension cord plugged from power strip below accordance with UL 817.Extension cords and flexible "Miller ,si n Life"High supplying cordsshall not be affixed to structures,extended through g g power to fan.Fan shall plug directly to a permanent outlet. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 8/5/26, 3:27 PM g OF 12 Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Hostess stand at South exit for permanent wiring and shall be listed and labeled in Comments:Remove all extension cords and remove flexible wiring accordance with UL 817.Extension cords and flexible noted extending into and through wall.Flexible wiring is prohibited cordsshall not be affixed to structures,extended through from extending through concealed spaces. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. • lb Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:SW corner-near jukebox for permanent wiring and shall be listed and labeled in Comments:Remove green and white extension cords plugged to accordance with UL 817.Extension cords and flexible jukebox and LED strip lights. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Women's bathroom for permanent wiring and shall be listed and labeled in Comments:Remove extension cord plugged to"Jose Cuervo"sign accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 8/5/26, 3:27 PM 10 OF 12 Commercial Cooking Hood Suppression System slaw= Code Description Fail 606.3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen exhaust hood appurtenances shall be cleaned at intervals as required by Comments:Owner is self-cleaning hood exhaust system.Owner shall Sections 606.3.3.1 through 606.3.3.3. establish an account at Compliance Engine to document hood cleanings at required intervals and cleaning standards,Contact Compliance Engine at(Email:npratt@mybrycer.com or Phone#(630) 701-6548).Currently 272 days past due. Portable Fire Extingusihers Status Corte Description Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Fire extinguishers maintained in accordance with this section and NFPA 10. Comments:Provide required annual service to extinguishers,last Exceptions:1.The distance of travel to reach an extinguisher recorded service completed May 2025 shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Kitchen-Class K extinguisher maintained in accordance with this section and NFPA 10. Comments:Provide annual service to extinguisher,last recorded Exceptions:1.The distance of travel to reach an extinguisher service completed May 2024 shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.1n Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 8/5/26, 3:27 PM 11 OF 12 E! Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 8/5/26, 3:27 PM 12 OF 12