Loading...
HomeMy WebLinkAboutRUDY'S TACO - 2401 FALLS AVENUE4588 W A T INVOICE DATE DUE DATE INVOICE# TOTAL DUE O F 4e 08/12/2026 09/16/2026 2027-00000073 $80.00 cO U.,ii/y+.. . O • II EMU III I 11 • > T- O Customer#: 4588 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable RUDY'S TACO 715 Mulberry St 2401 FALLS AV WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 2401 FALLS AVE-08/06/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4588 08/12/2026 09/16/2026 2027-00000073 $80.00 Less Prepayment $0.00 Total Due —> $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue r, Inspection Report 425 E.3rd Street Rudy's Tacos-2401 Falls AVE,BLDG 2401 Falls Ave,Waterloo IA 50701 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 08106/2026 Annual Inspection(1Yr) /s-ss 4 0),(0 17569 Lead inspector Shift Station Unit BRAD BALDWIN NIA NIA N/A Other Inspectors NIA SUMMARY OF INSPECTION 044 02 @27 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 08/24/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-08/06/2026 @ 13:41 •S80 annual inspection fee BRAD BALDWIN-08/06/2026 @ 13:41 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-08/06/2026 @ 13:41 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-08106/2026 @ 13:41 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-08/0612026 @ 13:41 Kitchen hood exhaust cleaning due on 8/16/26 SIGNATURES Contact signature Inspector signature No signature Report completededpost stinspection _EsK. Anthony Mashek Date: BRAD BALDWIN 08/06/2026 CHECKLISTS GENERATED ON 8/6/26, 1:45 PM 1 OF 3 Electrical Safety Description S-: coo, -e p Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Office storage room for permanent wiring and shall be listed and labeled in Comments:Remove extension cord plugged to security cameras. accordance with UL 817.Extension cords and flexible Would approve to replace with properly supported power strip with cordsshall not be affixed to structures,extended through manual reset for low wattage electronics only. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Portable Fire Extingusihers Description Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Fire extinguishers maintained in accordance with this section and NFPA 10. Comments:Provide annual service to all extinguisher,currently due Exceptions:1.The distance of travel to reach an extinguisher for service in August shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. 2 OF 3 GENERATED ON 8/6/26, 1:45 PM '@ Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $80.00 • Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 8/8/26, 1;45 PM 3 OF 3