Loading...
HomeMy WebLinkAboutWALMART - 1334 FLAMMANG DRIVE OF W A 7. INVOICE DATE DUE DATE INVOICE# TOTAL DUE , c 08/12/2026 09/16/2026 2027-00000075 $610.00 et. /, O • 'n ■mm� n • > *-�"" T O s 7v11�� Customer#: 4747 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable WALMART 715 Mulberry St 1334 FLAMMANG DR WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 1334 FLAMMANG DR-08/05/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 100,000 $600.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4747 08/12/2026 09/16/2026 2027-00000075 $610.00 Less Prepayment $0.00 Total Due - . $610.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 425 E.3rd Street Walmart#1496-1334 Flammang DR,BLDG 1334 Flammang Dr,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type I Inspection Number 08105/2028 Annual Inspection(1Yr) '�4 1 4�1 Q 18028 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors NIA SUMMARY OF INSPECTION 0 46 0 36 Q 11 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 08/27/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-08106/2026 @ 08:06 •$610 annual inspection fee BRAD BALDWIN-08/06/2026 @ 08:06 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-08106/2026 @ 08:07 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-08106/2026 @ 08:07 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-08/06/2026 @ 08:07 Kitchen hood cleaning due 10/6/26. BRAD BALDWIN-08/06/2026 @ 08:22 Commercial remodel permit obtained but work has yet to start due to legal issues.All required inspections shall be obtained as work is completed if project does continue. BRAD BALDWIN-08/06/2026 @ 12:18 Fire drop door test-2026 GENERATED ON 8/8/26, 1:38 PM 1 OF 16 1 y 8 1' jig • IutG&,l GHQ BRAD BALDWIN-0810612026 @ 13:37 8127126 re-inspection scheduled for 9am,inspector shall be contacted if need to re-schedule. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection LILLIAN CALDERON(2025) Date: BRAD BALDWIN 08106/2026 CHECKLISTS GENEPATED ON 8/6/26, 1:38 PM 2 OF 16 Means of Egress Status Code Description Fail 1010.1.3-Door opening force Forces to unlatch and open 0 doors. Location:Grocery receiving The force for pushing or pulling open interior swinging Comments:Repair or replace exit door requiring more than 15Ibs of egress doors,other than fire doors,shall not exceed 5 force to open.Replacement of door requires permit and inspection. pounds(22 N).These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position.For other swinging doors, as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N) force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following:1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N).2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm). The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full-open position when subjected to not more than a 15-pound(67 N)force. Emergency Equipment Status Code Description Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Whole building illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Provide documentation of testing all emergency egress lighting in the building including repairs completed to maintain working properly.Email document to inspector signed and dated. Fail 1203.2.6-Exit signs. (Jx Emergency power shall be provided for exit signs as required Location:Whole building in Section 1013.6.3.The system shall be capable of powering Comments:Provide documentation of testing all exit signage in the the required load for a duration of not less than 90 minutes. building including repairs completed to maintain working properly. Email document to inspector signed and dated. GENERATED ON 8/6/26, 1:38 PM 3 OF 16 General Housekeeping - Coc Description Fail 304,3.1-Spontaneous ignition. Materials susceptible to spontaneous ignition,such as oily Location:Kitchen rags,shall be stored in a listed disposal container.Contents Comments:Provide listed container with self-closing lid for disposal of such containers shall be removed and disposed of daily. of soiled rags and towels.Rags soiled with fats,oils or grease shall be disposed of in container and removed from building daily. • 4 OF 16 GENEPATED ON 8/6/26, 1:38 PM Additional Codes Status Cede Description Fail 3201.3.2-Approved storage layout. A floor plan,of legible size,shall be provided,mounted on a Location:Receiving&back storage area wall and protected from damage.The floor plan shall be Comments:Lower storage on top shelving higher than the marked mounted in an approved location and show the following: max height, 1,Locations,dimensions and rack layout of high-piled storage areas.2.Design storage height for each storage area.3.Types of commodities,4.Commodity clearance between top of storage and the sprinkler deflector for each storage arrangement,5.Aisle dimensions between each storage array. 6.For palletized and solid-piled storage,the maximum pile volume for each storage array.7.Location and classification of commodities in accordance with Section 3203.8.Location of required fire department access doors.9.Location of valves controlling the water supply of ceiling and in-rack sprinklers. Fail 503.3-Marking. Where required by the fire code official,approved signs or Location:Frontage of building other approved notices or markings that include the words Comments:All faded fire lane markings and signage shall be repaired "NO PARKING—FIRE LANE"shall be provided for fire or replaced. apparatus access roads to identify such roads or prohibit the obstruction thereof.The means by which fire lanes are designated shall be maintained in a clean and legible condition at all times and be replaced or repaired when necessary to provide adequate visibility. x Fail 507.5.3-Private fire service mains and water tanks. Private fire service mains and water tanks shall be Location:Private fire hydrants periodically inspected,tested and maintained in accordance Comments:Licensed contractor shall complete annual inspection of with NFPA 25 at the following intervals:1.Private fire hydrants of all types:Inspection annually and after each operation; hydrants and upload required report including deficiencies corrected flow test and maintenance annually.2.Fire service main to Compliance Engine.Due for inspection on 8/6126 piping:Inspection of exposed,annually;flow test every 5 years.3.Fire service main piping strainers:Inspection and maintenance after each use.Records of inspections,testing and maintenance shall be maintained. GENERATED ON 8/6/26, 1;38 PM 5 OF 16 Fail 603.1-General. Electrical equipment,wiring and systems required by this Location:Management office code or the International Building Code shall be installed, Comments:Mini fridge and pizza maker shall be removed from multi- used and maintained in accordance with NFPA 70 and plug adapter.Appliances with motors or heat producing elements Sections 603.2 through 603,10. shall plug directly to a permanent outlet. Fail 603.2.1-Modified or damaged. Ox Electrical wiring,devices,equipment and appliances that are Location:"Gameplay"room modified or damaged,and constitute an electrical shock or Comments:Outlet loosely installed in box shall be repaired and fire hazard,shall not be used until repaired or replaced in damaged cover replaced. accordance with this code and NFPA 70 ,:,t .. Fail 603.9.1-Listed and labeled. OOnly listed and labeled portable,electric space heaters shall Location:Vault room be used. Comments:Provide documentation of properly commercially listed space heater or must remove from building Fail 606.3.1-Ventilation system. The ventilation system in connection with hoods shall be Location:Kitchen hood exhaust operated at the required rate of air movement,and grease Comments:Close gaps between filters,gaps or filters not in place filters listed and labeled in accordance with UL 1046 shall be cause more grease in ductwork and on cables for fire suppression in place where equipment under a kitchen grease hood is used. GENERATED ON 8/6/26, 1:38 PM 6 OF 16 Fire Sprinkler System St!tus cocic Description Fail 5.2.1.1.5-Missing escutcheons Escutcheons and coverplates for recessed,flush,and Location:Bakery coved product shelving concealed sprinklers shall be replaced if found missing Comments:Sprinkler escutcheon shall be pushed up flush with during the inspection. ceiling. eat t ealtie '':., 1 flit .ise Fail 5.2.1.1.5-Missing escutcheons Escutcheons and coverplates for recessed,flush,and Location:Cart coral in west vestibule concealed sprinklers shall be replaced if found missing Comments:Loose escutcheon shall be installed flush with ceiling. during the inspection. Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Customer service-Above"CoinStar"machine obstructions that will delay activation or obstruct the water Comments:Remove dust/debris from sprinkler heads(2) distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. GENERATED ON 8/6/26, 1:38 PM 7 OF 16 Fall 903.3.3-Obstructed locations. OAutomatic sprinklers shall be installed with regard to Location:Produce cooler obstructions that will delay activation or obstruct the water Comments:Licensed electrical contractor shall relocate conduit from distribution pattern and shall be in accordance with the obstructing sprinkler head. applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. Fail 903.3.3-Obstructed locations. OAutomatic sprinklers shall be installed with regard to Location:Above and near west"self-checkout"area. obstructions that will delay activation or obstruct the water Comments:Remove dust/debris from several dirty sprinkler heads distribution pattern and shall be in accordance with the noted. applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Cart coral in west vestibule-Near hanging heater obstructions that will delay activation or obstruct the water Comments:Remove dust/debris from sprinkler head distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. GENERATED ON 8/8/26, 1:38 PM 8 OF 16 Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Vision Center obstructions that will delay activation or obstruct the water Comments:Remove dust/debris from sprinkler head above printer distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. Fail 903.3.3-Obstructed locations. Automatic sprinklers shall be installed with regard to Location:Garden Center(interior) obstructions that will delay activation or obstruct the water Comments:Umbrellas 4ft in width shall be removed or sprinkler distribution pattern and shall be in accordance with the applicable automatic sprinkler system standard that is being coverage added below by licensed sprinkler contractor, used.Automatic sprinklers shall be installed in or under covered kiosks,displays,booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width.Not less than a 3-foot(914 mm)clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers.Exception:Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. _ rrr; t� a . „y��� f GENERATED ON 8/6/26, 1:38 PM 9 OF 16 Electrical Safety Code Description Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Grocery freezer prohibited.Approved covers shall be provided for all switch Comments:Replace missing light switch cover and electrical outlet boxes. e. �,,y,uwaeA swemq b7 "u". wm�5°'"�pndoA" M.r “.s+nr. _i ' �, `t j Fail 603.4.1-Labeling. Doors into electrical control panel rooms shall be marked Location:General merchandise electric room(exterior) with a plainly visible and legible sign stating"ELECTRICAL Comments:Provide approved permanent signage on door indicating ROOM"or similar approved wording.The disconnecting 'Electric Room",laminated paper will not be accepted. means for each service,feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Fail 603.5.2-Application and usePower supply. Relocatable power taps and current taps shall be directly Location:Garden Center above shelving-Aisle Y15 connected to a permanently installed receptacle.Exceptions: Comments:Multiple daisy chained power strips on top shelf shall be 1.Where approved for use in a Group A occupancy or in a corrected.Each power strip shall plug directly to a permanent outlet. meeting room in a Group B occupancy,not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:Theft protection office ceilings,floors,under doors or floor coverings,or be subject Comments:Properly support power strip below desk to avoid to environmental or physical damage. hanging by wires. GENEP'.TED ON 8/6/26, 1:33 PM 10 OF 16 I Fail 603.6-Extension cords, Ox Extension cords and flexible cordsshall not be a substitute Location:Human resource TV monitor for permanent wiring and shall be listed and labeled in Comments:Monitor supply cord shall not pass through wall,Adding accordance with UL 817.Extension cords and flexible a new outlet to complete repair requires a licensed electrical cordsshall not be affixed to structures,extended through contractor to obtain a permit and inspection. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. OExtension cords and flexible cordsshall not be a substitute Location:Back storage-Near floor scrubber charging area for permanent wiring and shall be listed and labeled in Comments:Extension cords shall not be used as permanent wiring. accordance with UL 817.Extension cords and flexible Also,green multi-plug adapter shall be removed,approved to replace cordsshall not be affixed to structures,extended through with walls,ceilings or floors,or under doors or floor coverings, properly su supported power strip for low wattage electronics only. nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. at it Ili,",� r` f attl a Fail 603.6-Extension cords. 1 0 Extension cords and flexible cordsshall not be a substitute Location:Theft detection office for permanent wiring and shall be listed and labeled in Comments:Mobile AC unit plugged to extension cord shall plug accordance with UL 817.Extension cords and flexible directly to a permanent outlet,currently plugged to extension cord cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 8/6/26, 1:38 PM 11 OF 16 Fail 603.6-Extension cords. OExtension cords and flexible cordsshall not be a substitute Location:Dressing rooms for permanent wiring and shall be listed and labeled in Comments:Lighted mirror supply cord shall not extend above drop accordance with UL 817.Extension cords and flexible ceiling. cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. ` S' {. 4.4 ♦♦ Need asi size? Commercial Cooking Hood Suppression System Description Fail 606.3.3.1-Inspection. Hoods,grease-removal devices,fans,ducts and other Location:Kitchen hood suppression system appurtenances shall be inspected at intervals specified in Comments:Provide required bi-annual inspection and report to be Table 606.3.3.1 or as approved by the fire code official. uploaded to Compliance Engine including all deficiencies corrected. Inspections shall be completed by qualified individuals. Past due since 3125/26.Inspection by Averus INC in March 2026 rejected due to lack of proper license with the State Of Iowa. GENERATED ON 8/6/26, 1:38 PM 12 OF 16 Fire Resistant Construction Maintenance Statu Corte Description Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:West exit vestibule materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tile. following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:Subway room materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tiles following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. GENERATED ON 8/6/26, 1:38 PM 13 OF 16 ` y Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:Grocery back room materials and systems used to protect joints and voids in the Comments:Carefully remove paint from fire rating tags without following locations shall be maintained.The materials and altering or removing tag information on double doors. systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or rooflceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:Break room hallway materials and systems used to protect joints and voids in the Comments:Carefully remove paint from fire rating tags without following locations shall be maintained.The materials and altering or removing tag information on double doors. systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or rooflceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonf ire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. GENERATED ON 8/6/26, 1:38 PM 14 OF 16 Fall 704.1-Maintaining protection. 0 Where required when the building was originally constructed, Location:Aisle 1-31 near garden center materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tile. following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floorlceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Fail 705.2.4-Door operation. Swinging fire doors shall close from the full-open position Location:Break room hallway and latch automatically. Comments:Double fire doors not self-shutting and latching shall be repaired. Portable Fire Extingusihers Status Code Description Fail 906.2-General requirements. OPortable fire extinguishers shall be selected,installed and Location:Claims cage maintained in accordance with this section and NFPA 10. Comments:Spare extinguisher sitting on floor past due for service. Exceptions:1.The distance of travel to reach an extinguisher Complete annual service or remove from building. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Fail 906.6-Unobstructed and unobscured. Portable fire extinguishers shall not be obstructed or Location:Subway room obscured from view.In rooms or areas in which visual Comments:Remove fire extinguisher indication signage, obstruction cannot be completely avoided,means shall be extinguisher has been relocated. provided to indicate the locations of extinguishers. GENERATED ON 8/6/26, 1:38 PM 15 OF 16 } 'D Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $610.00 Invoice Number Check Number Transaction Number N/A NIA NIA GENERATED ON 8/6/26, 1:38 PM 16 OF 16