Loading...
HomeMy WebLinkAbout3561 UNIUVERSITY AVE \„\ �� INVOICE DATE DUE DATE INVOICE# TOTAL DUE ��`�'� �\���� 01/04/2021 .,at, 02/10/2021 2021-00000179 $100.00 NsAir Customer#: 23524 Please Make Check Payable and Remit To: City of Waterloo A TTN: City Clerk/Accounts Receivable FULL COUNT SPORTS ACADEMY 715 Mulberry St 3561 UNIVERSITY AVE WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-3561 UNIVERSITY AVE- 12-16-20 IFOR BILLING INQUIRY: (319)291-4323 LDescription Total Price j INSPECTION 20,000 OCCUPANCY FEE $90.00 $10.00 CUSTOMER# I BILLING DATE DUE DATE INVOICE# CHARGES 23 524 01/04/2021 02/10/2021 2021-0000017 9 $100.00 Less Prepayment $0.00 Total Due—� $100.00 City of Waterloo WATERLOO FIRE RESCUE INSPECTION REPORT 44� 'as FULL COUNT SPORTS ACADEMY,3561 UNIVERSITY AVE,BLDG 3561 UNIVERSITY AVE s \� WATERLOO IA 50701 4ZZO Inspection Date: 12/16/2020 I Inspection Type:Annual Inspection,(1Yr) I Inspection N Unit: N/A 'ead Inspector:JEFF SIEBEL Other Inspectors: N/ ' Fee:$100.00 umber:2638 Shift: N/A ; Station: N/A STATUS CODE DESCRIPTION FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously free from obstructions or impediments to full instant use in the case of fire oarined other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:JEFF SIEBEL-Comments:Install landing outside rear exit with proper permits and inspections. FAIL 5.2.1 -Annual sprinkler Sprinklers shall be inspected at least annually bylicensed system inspection contractor Inspector:JEFF SIEBEL-Comments:/provide documentation of corrections for annual fire/sprinkler inspection by Continental dated.Contractor must upload corrections online to the compliance engine. FAIL 505.1 -Address identification New and existing buildings shall be provided with approved The address identification shall be legible and placed in a position that entif is visible from the street or road fronting the property.Address identification characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 1/2(12.7 mm). Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector:JEFF SIEBEL-Comments:properly install address for space including suite nurnbert. Printed on 01/04/2021 @ 15:35 Page 1 of 3 . STATUS CODE DESCRIPTION FAI - 506.1 -Where required Where access to or within a structure or an area is restricted because openings or where immediate access is necessary for life-saving or fire-fighting secured purposes,the fire code official is authorized to require a key box to be installed approved location.The key box shall be of an approved type listed in accordance tailed in an UL 1037,and shall contain keys to gain necessary access as required de official. q by the fire code Inspector:JEFF SIEBEL-Comments:Install a knox-box from knox-box fighter access.Contact Fire Marshal 319-793-1136 for location, .corn for fire FAIL 509.1 -Identification Fire protection equipment shall be identified in an approved manner. containing controls for air-conditioning systems,sprinkler risers and valves, Rooms fire detection,suppression or control elements shall be identified for fire department.Approved signs required to identifyfireon or other theuse equipment the equipment location shall be constructed of durable materri ls,pema ently i and and readily visible. permanently installed Inspector:JEFF SIEBEL-Comments:Install permanent"Fire S rinkl Sign"on outside of door to fire sprinkler. Provide key in knoxbox forr RiserRoom sheetrock wall, doos r.Repair FAIL 604.2.12-Means of egress illumination Emergency power shall be provided for means of e ress ill with Sections 1008.3 and 1104.5.1. g umination in accordance Inspector:JEFF SIEBEL-Comments:repair egress lights hanging g g by wires on wall. FAIL 605.1 -Abatement of electrical.1- e Identified electrical hazards shall be abated. Identified hazardous in permanent wiring shall be brought to the attention of the responsibleelectrical conditions Electrical wiring,devices,appliances and other equipment that is moth do r official. damaged and constitutes an electrical shock or fire hazard shall not be s or be used. Inspector:JEFF SIEBEL-Comments:properly mount water heater that is currently hanging by wires.FAI - 906.1 -Where required Portable fire extinguishers shall be installed in all of the following and existing Group A,B,E,F,H,I,M,R-1,R-2,R-4 and S occupancies.Exception: 1.In new Group R-2 occupancies,portable fire extinguishers shall be requirednly il a specified in Items 2 through 6 where each dwelling unit is provided with e fire extinguisher having a minimum ratingof 1-A: only in locations of commercial cooking equipment.3. In areas where10 B. C 2.Within 30 feet 9044 ml m) liquids are stored,used or dispensed.4.On each flooflammable of s Obit or combustible construction,except Group R-3 occupancies,in accordance with Section structures under Where required by the sections indicated in Table 906.1.6.Special-hazard 3315.1.re 5. including but not limited to laboratories,computer rooms and eetor room where required by the fire code official. generator rooms, Inspector:JEFF SIEBEL-Comments:Install currently serviced 2A- in an accessible location 4"to 5'above the floor, bC fire extinguishers Printed on 01/04/2021 @ 15:35 Page 2 of 3 GENERAL NOTES JEFF SIEBEL-01/04/2021 @ 15:28 annual inspection$100 REINSPECT/ON DATE 01/18/2021 CONTACT SIGNATURE Eric Grattan Signed on:01/04/2021 @ 15:32 a INSPECTOR SIGNATURE JEFF SIEBEL Signed on:01/04/2021 @ 15:33 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 01/04/2021 @ 15:35 Page 3 of 3