Loading...
HomeMy WebLinkAbout1108 JEFFERSON ST INVOICE DATE DUE DATE INVOICE# TOTAL,DUE 01/04/2021 02/10/2021 2021-00000170 $80.00 Customer#: 23517 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ELITE CAFE AND BAR 715 Mulberry St 1108 JEFFERSON ST WATERLOO, IA 50703 WATERLOO,IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1108 JEFFERSON ST- 12-8-20 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price j INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23517 01/04/2021 02/10/2021 2021-00000170 $80.00 Less Prepayment $0.00 Total Due—+ $80.00 City of Waterloo •„ C6)0Sh krvATERLOO FIRE RESCUE INfF &BA08JEFFESON T 1 ELI CAE R, ST,BLDG 1108 JEFFERSON ST,WATERLOO IA 50702 42404 DETAILS Inspection Date 12/0 /2020 Inspection Type:Annual Inspection(1Yr) 1 Inspection Number:4024 1 Shift: N/A 1 Station: N/A Unit: N/A 1 Lead Inspector:JEFF SIEBEL 1 Other Inspectors: N/A 1 Fee:$80.00 STATUS CODE DESCRIPTION FAIL 906.2-General requirements Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1. Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguisher at top of stairs in shop. FAIL 906.6-Unobstructed and Portable fire extinguishers shall not be obstructed or obscured from view. In rooms unobscured or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of extinguishers. Inspector:JEFF SIEBEL-Comments:remove obstruction to fire extinguisher in car sales room. Maintain a minimum of 36"clearance. FAIL 906.7-Hangers and brackets Hand-held portable fire extinguishers, not housed in cabinets,shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:properly hang fire extinguisher in an accessible location 4"to 5'above the floor in the truck dispatch area. GENERAL NOTES JEFF SIEBEL-12/08/2020 @ 13:42 annual inspection$80 Printed on 12/08/2020 @ 14:00 Page 1 of 2 ,niSPECTION DATE 01/07/2021 CONTACT SIGNATURE Sanal Devic Signed on: 12/08/2020 @ 13:56 rec INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 12/08/2020 @ 13:56 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 12/08/2020 @ 14:00 Page 2 of 2