COMMERCIAL INSPECTION- 1727 COMMERCIAL ST- 12-14-20 FOR BILLING INQUIRY: (319)291-4323
L Description I Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
20972 01/04/2021 02/10/2021 2021-00000169 $80.00
Less Prepayment $0.00
Total Due $80.00
City of Waterloo
ATERLO
ealc-P') ..4.0 0
T
INSPECTION REPORT _� �. ®_o .` :
RETO FOAM, 1727 COMMERCIAL ST,Bl 61727 COMMERCIAL ST,WATERLOO IA 50702 44
DEr
InspectiogDate: 12/14/2020 inspection Type:Annual Inspection(1Y nspec on Number: 1571 I Shift: N/A Station: N/A I
Unit: N/4i I Lead Inspector.JEFF SIEBEL ; Other Inspectors: N/A rPee:$80.00
STATUS CODE DESCRIPTION
FAIL 315.3.1 -Ceiling clearance Storage shall be maintained 2 feet(610 mm)or more below the ceiling in`
nonsprinklered areas of buildings or not less than 18 inches(457 mm)below
sprinkler head deflectors in sprinklered areas of buildings.
Inspector:JEFF SIEBEL-Comments: reduce storage on loft to a minimum of 24" below
the ceiling
FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments:repair exit/egress lights at front and back exit
doors.
FAIL 605.3-Working space and A working space of not less than 30 inches(762 mm)in width,36 inches(914 mm)in
clearance depth and 78 inches(1981 mm)in height shall be provided in front of electrical
service equipment.Where the electrical service equipment is wider than 30 inches
(762 mm),the working space shall be not less than the width of the equipment.
Storage of materials shall not be located within the designated working space.
Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access
openings into attics or under-floor areas which provide a minimum clear opening of
22 inches(559 mm)by 30 inches(762 mm).
Inspector:JEFF SIEBEL-Comments:remove obstructions to electric panel. maintain a
minimum of 36"clearance.
Printed on 12/15/2020 @ 14:29
Page 1 of 3
4
f
STATUS CODE DESCRIPTION
FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall
be allowed to be once every 3 years for dry-chemical or halogenated agent portable
fire extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1. Electronic
monitoring shall confirm that extinguishers are properly positioned, properly
charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic
monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be
installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic
monitoring devices and supervisory circuits shall be tested every 3 years when
extinguisher maintenance is performed.2.5.A written log of required hydrostatic
test dates for extinguishers shall be maintained by the owner to verify that
hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3,
portable fire extinguishers shall be permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers
FAIL 906.7-Hangers and brackets Hand-held portable fire extinguishers,not housed in cabinets,shall be installed on
the hangers or brackets supplied. Hangers or brackets shall be securely anchored to
the mounting surface in accordance with the manufacturer's installation instructions.
Inspector:JEFF SIEBEL-Comments:properly mount fire extinguishers 4"to 5'above
the floor in an accessible location.
GENERAL NOTES
JEFF SIEBEL-12/15/2020 @ 14:23 annual inspection $80
REINSPECTION DATE
01/07/2021
CONTACT SIGNATURE
Jeff Smith L
Signed on: 12/15/2020 @ 14:27 �1?c/ ..
T� r
Printed on 12/15/2020 @ 14:29