COMMERCIAL INSPECTION- 1719 COMMERCIAL ST- 12-14-20 FOR BILLING INQUIRY: (319)291-4323
L Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23515 01/04/2021 02/10/2021 2021-00000171 $80.00
Less Prepayment $0.00
Total Due--> $80.00
City of Waterloo
r s \
1
TE
iLO � � TER(
3
IRES31P OO
INSPECTION REPORT
LIQUIDATION SALE,1719 COMMERCIAL ST,BLDG 1719 COMMERCIAL ST, WATERLOO/A 50702
DETAILS
Inspection Dat : 12/14/2020 I Inspection Type:Annual Inspection(1 Yr) Inspection Number:5324 Shift: N/A i Station: N/A
Unit: N/A I Lea` Inspector:JEFF SIEBEL I Other Inspectors: N/A
STATUS CODE DESCRIPTION
FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector:JEFF SIEBEL-Comments:maintain an obstructed path to rear(street)exit.
FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments:repair egress,exit light above exit door to alley.
FAIL 605.3-Working space and A working space of not less than 30 inches(762 mm)in width,36 inches(914 mm)in
clearance depth and 78 inches(1981 mm)in height shall be provided in front of electrical
service equipment.Where the electrical service equipment is wider than 30 inches
(762 mm),the working space shall be not less than the width of the equipment.
Storage of materials shall not be located within the designated working space.
Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access
openings into attics or under-floor areas which provide a minimum clear opening of
22 inches(559 mm)by 30 inches(762 mm).
Inspector:JEFF SIEBEL-Comments: Maintain a minimum of 36"clearance to and
around electric panel at all times.remove obstructions.
Printed on 12/15/2020 @ 14:07
Page 1 of 3
STATUS CODE DESCRIPTION
906.2-General requirements Portable fire extinguishers shall be selected, installed and maintained in accordance
with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall
be allowed to be once every 3 years for dry-chemical or halogenated agent portable
fire extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1.Electronic
monitoring shall confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic
monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be
installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic
monitoring devices and supervisory circuits shall be tested every 3 years when
extinguisher maintenance is performed.2.5.A written log of required hydrostatic
test dates for extinguishers shall be maintained by the owner to verify that
hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3,
portable fire extinguishers shall be permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments: Provide annual service for fire extinguishers. Last
completed in 2014
GENERAL NOTES
JEFF SIEBEL-12/15/2020 @ 14:04 Annual Inspection$80
REINSPECTION DATE
01/07/2021
CONTACT SIGNATURE
Nicole Floss
Signed on: 12/15/2020 @ 14:02ec4
c.„O Q
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on: 12/15/2020 @ 14:03
Printed on 12/15/2020 @ 14:07