COMMERCIAL INSPECTION- 1931 SEARS ST- 1-6-21 FOR BILLING INQUIRY: (319)291-4323
L Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
22165 02/09/2021 03/15/2021 2021-00000210 $80.00
Less Prepayment $0.00
Total Due $80.00
City of Waterloo
ATERLOO FIRERESCUE \ &--T£R 0o
INSPECTION REPORT : �'
TOKYO BAY,1931 SEARS ST,BLDG 1931 SEARS ST,WATERLOO IA S0702 4400
DETAILS
Inspection Date:01/06/2021 I Inspection Type:Annual Inspection(1Yr) j Inspection Number:4879 ! Shift: N/A Station: N/A
Unit: N/A I Lead Inspector:JEFF SIEBEL Other Inspectors: N/A I Fee:$80.00
STATUS CODE DESCRIPTION
FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector:JEFF SIEBEL-Comments:remove chair and high chair storage from west
exit door in dining room.
FAIL 305.1 -Clearance from Clearance between ignition sources,such as luminaires,heaters,flame-producing
ignition sources devices and combustible materials,shall be maintained in an approved manner.
Inspector:JEFF SIEBEL-Comments:remove oily waste container from next to water
heater. Maintain 36"clearance to water heater at all times.
FAIL 605.3-Working space and A working space of not less than 30 inches(762 mm)in width,36 inches(914 mm)in
clearance depth and 78 inches(1981 mm)in height shall be provided in front of electrical
service equipment.Where the electrical service equipment is wider than 30 inches
(762 mm),the working space shall be not less than the width of the equipment.
Storage of materials shall not be located within the designated working space.
Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access
openings into attics or under-floor areas which provide a minimum clear opening of
22 inches(559 mm)by 30 inches(762 mm).
Inspector:JEFF SIEBEL-Comments:maintain a minimum of 36"to and around
electrical panels.(Remove obstructions on stairs to electrical room).
FAIL 609.3.3.1 -Inspection Hoods,grease-removal devices,fans,ducts and other appurtenances shall be
inspected at intervals specified in Table or as approved by the fire code official.
Inspections shall be completed by qualified individuals.
Inspector:JEFF SIEBEL-Comments: Provide current semi-annual kitchen hood
exhaust system cleaning/inspection report with all discrepancies corrected.
Contractor must upload online to the Compliance Engine.
Printed on 01/07/2021 @ 11:19
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 609.3.3.3-Records Records for inspections shall state the individual and company performing the
inspection,a description of the inspection and when the inspection took place.
Records for cleanings shall state the individual and company performing the cleaning
and when the cleaning took place.Such records shall be completed after each
inspection or cleaning and maintained.
Inspector:JEFF SIEBEL-Comments:Provide current semi-annual kitchen hood
exhaust system cleaning/inspection and fire suppression report with all
discrepancies corrected.Contractor must upload online to the Compliance Engine.
FAIL 904.12.6.2-Extinguishing Automatic fire-extinguishing systems shall be serviced at least every six months and
system service after activation of the system. Inspection shall be by qualified individuals,and a
certificate of inspection shall be forwarded to the fire code official upon completion.
Inspector:JEFF SIEBEL-Comments: Provide current semi-annual kitchen hood
exhaust system fire suppression inspection report with all discrepancies corrected.
Contractor must upload online to the Compliance Engine.
FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor
testing,and maintenance
Inspector:JEFF SIEBEL-Comments:provide annual inspection for fire alarm system.
Contractor must upload online to the compliance engine.
GENERAL NOTES
JEFF SIEBEL-01/07/2021 @ 11:16 annual inspection $80
JEFF SIEBEL-01/07/2021 @ 11:16 clothes dryer disconnected not in use.
JEFF SIEBEL-01/07/2021 @ 11:17 Fire sprinkler due 1/20/21 (14 days). Please Schedule.
REINSPECTION DATE
01/27/2021
CONTACT SIGNATURE
Anna Nouyen
Signed on:01/07/2021 @ 11:17 -/61 �y
Printed on 01/07/2021 @ 11:19
Page 2 of 3
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:01/07/2021 @ 11:17
QUESTIONS ABOUT YOUR INSPECTION'
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed on 01/07/2021 @ 11:19
Page 3 of 3