Loading...
HomeMy WebLinkAbout3555 UNIVERSITY AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE 11�14e�. 02/09/2021 03/15/2021 2021-00000209 $80.00 ,;;?terlo0 � Customer#: 13209 Please Make Check Payable and Remit To: City of Waterloo A TTN: City Clerk/Accounts Receivable SPICOLI'S 715 Mulberry St 3555 UNIVERSITY AV WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-3555 UNIVERSITY AVE- 12-16-20 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price J INSPECTION 1 HH $70.00 OCCUPANCY FEE $10.00 CUSTOMER# I BILLING DATE DUE DATE INVOICE# CHARGES 13209 02/09/2021 03/15/2021 I 2021-00000209 $80.00 Less Prepayment $0.00 Total Due--> $80.00 City of Waterloo WATERLOOFIRE RESCUEe INSPECTION REPORT �;4 SPICOLI'S,MSS UNIVERSITYAVE,BLDG MSS UNIVERSITYAVE,WATERLOO/A S0T01 4400 DETAILS Inspection Date: 12/16/2020 Inspection Type:Annual Inspection(1Yr) Inspection Number:3254 Shift: N/A Station: N/A Unit: N/A i Lead Inspector:JEFF SIEBEL Other Inspectors: N/A ; Fee:$80.00 STATUS CODE DESCRIPTION FAIL 5.2.1 -Annual sprinkler Sprinklers shall be inspected at least annually by licensed contractor system inspection Inspector:JEFF SIEBEL-Comments:Provide annual fire sprinkler inspection with all discrepancies corrected. Contractor must upload online to the compliance engine. Provide a color-coded map or key to outline exactly which buildings are covered by each fire sprinkler and fire alarm system. Must be postage and every fire sprinkler riser room FAIL 506.2-Key box maintenance The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed.The key to such lock shall be secured in the key box. Inspector:JEFF SIEBEL-Comments:Supply new key for a new lock on door to be placed in Knox-box for firefighter access FAIL 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:Repair egress light south wall.Test and repair outside exit/egress lights FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:JEFF SIEBEL-Comments: Properly contain all exposed wiring in approved junction boxes with listed covers Printed on 01/05/2021 @ 08:17 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including, but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered,breached or penetrated. Records of inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel,access door,ceiling tile or similar movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector:JEFF SIEBEL-Comments:Replace all missing ceiling tile in order for fire sprinkler system to function as designed FAIL 903.3.1 -Standards Sprinkler systems shall be designed and installed in accordance with Section 903.3.1.1,unless otherwise permitted by Sections 903.3.1.2 and 903.3.1.3 and other chapters of this code,as applicable. Inspector:JEFF SIEBEL-Comments: Replace all missing ceiling tile or contact contractor to adjust fire sprinkler coverage without ceiling FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor testing,and maintenance Inspector:JEFF SIEBEL-Comments: Provide annual fire alarm inspection report with all discrepancies corrected. Contractor must Upload online to the compliance engine GENERAL NOTES JEFF SIEBEL-01/05/2021 @ 08:15 Annual fire inspection$80 JEFF SIEBEL-01/05/2021 @ 08:15 Immediately repair ceiling or redesign fire sprinkler system for proper coverage REINSPECTION DATE 01/18/2021 Printed on 01/05/2021 @ 08:17 Page 2 of 3 CONTACT SIGNATURE Stephen Jordan e t, Signed on:01/05/2021 @ 08:13 Ci COP )'\ INSPECTOR SIGNATURE JEFF SIEBEL Signed on:01/05/2021 @ 08:13 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 01/05/2021 @ 08:17 Page 3 of 3