Loading...
HomeMy WebLinkAbout210 E TOWER PARK DR //11\k -� INVOICE I}ATE DUE DATE INVOICE#/��## I14 TOTAL DUE " ���''� 02/09/2021 03 /15/2021 2021-00000207 $610.00 VG—) ‘o Customer#: 10758 Please Make Check Payable and Remit To: City of Waterloo A TTN: City Clerk/Accounts Receivable SAM'S CLUB#6514 715 Mulberry St 210 E TOWER PARK DR WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COIVIlVIERCIAI,INSPECTION-210 E TOWER PARK DR- 1-14-21 IFOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price J INSPECTION 100,000 OCCUPANCY FEE $600.00 $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CAGES 10758 02/09/2021 03/15/2021 2021-00000207 $610.00 Less Prepayment $0.00 Total Due $610.00 City of Waterloo + i WATERLOOFIRE RESCUE �P�ER(pp INSPECTION REPORT SAM'S CLUB,210 E TOWER PARK DR,BLDG 210 E TOWER PARK DR,WATERLOO IA 50701 44(0 DETAILS Inspection Date:01/14/2021 I Inspection Type:Annual Inspection(1Yr) Inspection Number:4809 I Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL Other Inspectors: N/A I Fee:$610.00 STATUS CODE DESCRIPTION FAIL 5.2.1.1.6-Missing Escutcheons and coverplates for recessed,flush,and concealed sprinklers shall be escutcheons replaced if found missing during the inspection. Inspector:JEFF SIEBEL-Comments:replace missing fire sprinkler escutcheon in pop closet at front of store. FAIL 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments: Repair all egress lights including:A. by front counter in kitchen. B.women's restroom by fire sprinkler riser. FAIL 604.4.2-Records Records of the inspection,testing and maintenance of emergency and standby power systems shall include the date of service,name of the servicing technician,a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken.Such records shall be maintained. Inspector:JEFF SIEBEL-Comments: Provide documentation of testing and repair of all egress and exit lights including ceiling. Report dated 1/4/21 by Ryan Filcher only lists 9 egress lights. FAIL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including, but not limited to,walls,firestops,shaft enclosures, partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered, breached or penetrated. Records of inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel,access door,ceiling tile or similar movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tiles in The Money Room. Printed on 01/19/2021 @ 10:38 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 903.3.3-Obstructed locations Automatic sprinklers shall be installed with due regard to obstructions that will delay activation or obstruct the water distribution pattern.Automatic sprinklers shall be installed in or under covered kiosks,displays, booths,concession stands or equipment that exceeds 4 feet(1219 mm)in width. Not less than a 3-foot(914 mm) clearance shall be maintained between automatic sprinklers and the top of piles of combustible fibers. Exception: Kitchen equipment under exhaust hoods protected with a fire-extinguishing system in accordance with Section 904. Inspector:JEFF SIEBEL-Comments:sprinkler head in women's restroom at front is loaded.provide correction. FAIL Table 8.1.1.2-Fire pump Fire pump being tested(run)?Weekly for diesel/monthly for electric. inspection,testing,and maintenance Inspector:JEFF SIEBEL-Comments: Fire pump testing ok. Provide annual diesel engine service. GENERAL NOTES JEFF SIEBEL-01/19/2021 @ 09:58 annual inspection$610 JEFF SIEBEL-01/19/2021 @ 09:59 multi-plug adapter in HMS corrected during inspection. JEFF SIEBEL-01/19/2021 @ 10:25 Maximum storage height per fire sprinkler design in general merchandise areas is 18'. Review current storage heights and reduce to allowable height. JEFF SIEBEL-01/19/2021 @ 10:29 kitchen hood cleaning 10/2/20 Assure. Due 4/2/21 JEFF SIEBEL-01/19/2021 @ 10:32 kitchen hood fire suppression Hawkeye Fire 9/9/20. Due 3/9/21 JEFF SIEBEL-01/19/2021 @ 10:31 annual fire alarm 5/14/20 walmart security JEFF SIEBEL-01/19/2021 @ 10:33 Annual fire sprinkler Viking 8/25/20 JEFF SIEBEL-01/19/2021 @ 10:33 Annual fire pump function Viking 8/25/20 JEFF SIEBEL-01/19/2021 @ 10:34 private fire hydrants viking 5/11/20 Printed on 01/19/2021 @ 10:38 Page 2 of 3 REINSPECTION DATE 02/04/2021 CONTACT SIGNATURE Dave Emerson Signed on:01/19/2021 @ 10:35 _b\VE INSPECTOR SIGNATURE JEFF SIEBEL Signed on:01/19/2021 @ 10:35 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 01/19/2021 @ 10:38 Page 3 of 3