Loading...
HomeMy WebLinkAbout501 W 4TH ST '"r"'�, INVOICE DATE DUE DATE INVOICE# TOTAL DUE /-� Jii /�+�11�',► ��• 02/09/2021 03/15/2021 2021-00000216 $80.00 Customer#: 20254 Please Make Check Payable and Remit To: City of Waterloo A TTN: City Clerk/Accounts Receivable HAA,LLC 715 Mulberry St 1505 DANISH DR WATERLOO, IA 50703 CEDAR FALLS,IA 50613 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-501 W 4TH ST- 1-8-21 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 20254 02/09/2021 03/15/2021 2021-00000216 $80.00 Less Prepayment $0.00 Total Due—> $80.00 City of Waterloo 1-1 A TERL O FIRE2 RESCUE5 , ,TER(oo INSPECTION REPORT 501 W 4TH,309 W 4TH ST,BLDG 50'W 4TH ST, WATERLOO IA 50702 `\ I rr\\ DETAILS Inspection Date:01/08/2021 I Inspection Type:Annual Inspection(1Yr) -tion Number:1245 I Shift: N/A Station: N/A Unit: N/A I Lead Inspector: BROCK WELIVER I Other Inspectors:)EFF Sit $80.00 STATUS CODE DESCRIPTION FAIL 1004.3-Posting of occupant Every room or space that is an assembly occupancy shall have the occupant load of load the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or the owner's authorized _ agent. Inspector: BROCK WELIVER-Comments:Occupant Load was missing during the inspection. ****This item has since been corrected.The Occupant Load was calculated,updated and proper signage was given to the tenant.This sign needs to be displayed as outlined above FAIL 1010.1.3-Door opening force The force for pushing or pulling open interior swinging egress doors,other than fire doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors,as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force. Inspector: BROCK WELIVER-Comments:The front door was difficult to open during � f /� .i.s.✓/ ,'' i ****nspection. This item was corrected as of 1-8-2021,B&B Locksmith was on scene and was able to make adjustments to the door to help it function properly. Printed on 01/08/2021 @ 17:40 Page 1 of 11 STATUS CODE DESCRIPTION FAIL 1010.1.9.4-Bolt locks Manually operated flush bolts or surface bolts are not permitted. Exceptions: 1.On doors not required for egress in individual dwelling units or sleeping units.2.Where a pair of doors serves a storage or equipment room,manually operated edge-or , surface-mounted bolts are permitted on the inactive leaf.3.Where a pair of doors serves an occupant load of less than 50 persons in a Group B, F or S occupancy, manually operated edge-or surface-mounted bolts are permitted on the inactive leaf.The inactive leaf shall not contain doorknobs,panic bars or similar operating -44 hardware.4.Where a pair of doors serves a Group B,F or S occupancy,manually operated edge-or surface-mounted bolts are permitted on the inactive leaf provided 717 _— such inactive leaf is not needed to meet egress capacity requirements and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1.The inactive leaf shall not contain doorknobs,panic bars or similar operating hardware.5.Where a pair of doors serves patient care rooms in Group 1-2 occupancies,self-latching edge-or surface-mounted bolts are permitted on the inactive leaf provided that the inactive leaf is not needed to meet egress capacity requirements and the inactive leaf shall not contain doorknobs, panic bars or similar operating hardware. Inspector: O -are Comments:Bolt Locks and Thumb Turn were found on the back doorBR.OK TheseWELIVER items art of the Do Not Occu r **** p py o der. These items have been removed by the tenant as of 1630 hours on 1-8-2021. saa FAIL 1031.6-Finishes,furnishings Means of egress doors shall be maintained in such a manner as to be distinguishable and decorations from the adjacent construction and finishes such that the doors are easily recognizable as doors. Furnishings,decorations or other objects shall not be placed so as to obstruct exits,access thereto,egress therefrom,or visibility thereof. Hangings and draperies shall not be placed over exit doors or otherwise be located to conceal or obstruct an exit. Mirrors shall not be placed on exit doors. Mirrors shall not be placed in or adjacent to any exit in such a manner as to confuse the direction of exit. x _ Inspector: BROCK WELIVER-Comments:Coverings have been put on the front door. ; Remove the covers so that the front door is easily identifiable in the event of an L.L...` emergency. Printed on 01/08/2021 @ 17:40 Page 2 of 11 STATUS CODE DESCRIPTION FAIL 316.3-Pitfalls The intentional design or alteration of buildings to disable,injure, maim or kill intruders is prohibited.A person shall not install and use firearms,sharp or pointed objects, razor wire,explosives,flammable or combustible liquid containers,or dispensers containing highly toxic,toxic,irritant or other hazardous materials in a manner that could passively or actively disable,injure, maim or kill a fire fighter who forcibly enters a building for the purpose of controlling or extinguishing a fire, rescuing trapped occupants or rendering other emergency assistance. Inspector:BROCK WELIVER-Comments: Potential Pitfall area found in the shared tenant space in the basement FAIL 505.1 -Address identification New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property.Address identification characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 1/2(12.7 mm). Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector:BROCK WELIVER-Comments:Address is needed on the front of the building Printed on 01/08/2021 @ 17:40 Page 3 of 11 STATUS CODE DESCRIPTION FAIL 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination with Sections 1008.3 and 1104.5.1. Inspector:BROCK WELIVER-Comments:Egress lights were out when tested: 1) combo light above back door,2)egress light in middle of building near the pool table, 3)combo light above front door,4)combo light in basement icy Printed on 01/08/2021 @ 17:40 Page 4 of 11 STATUS CODE DESCRIPTION FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector: BROCK WELIVER-Comments: Exit lights were out when tested: 1)combo light above back door,2)combo light above front door,3)combo light in basement r� 1 eta Printed on 01/082021 @ 17:40 Page 5 of 11 , STATUS CODE DESCRIPTION FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BROCK WELIVER-Comments:Cover missing off of main panel in the r---V,. '4'___,:-___ les -t basement-replace front panel --- - / ' FAIL 605.4.3-Installation Relocatable power tap cords shall not extend through walls,ceilings,floors,under doors or floor coverings,or be subject to environmental or physical damage. Inspector: BROCK WELIVER-Comments:Power tap behind the bar near the front t .:I door was found hanging.Secure power tap to a wall or keep power tap rested on a horizontal surface to prevent damage. --- %," - y". 7 t f Printed on 01/08/2021 @ 17:40 Page 6 of 11 STATUS CODE DESCRIPTION FAIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Inspector: BROCK WELIVER-Comments:Extension cords were found extending through the ceiling in multiple places: 1)back room near exit door-improper wiring from light switch extending up through ceiling,2)power cord from outlet above the mirror wall extends through ceiling,3)wire from music equipment next to back bathroom extends through ceiling Printed on 01/08/2021 @ 17:40 Page 7 of 11 STATUSDESCRIPTION CODE FAIL 605.6-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers conditions shall be provided for all switch and electrical outlet boxes. Inspector: BROCK WELIVER-Comments:Open junction boxes and open wire splices were found in multiple locations: 1)open cable plug on light switch by pool table,2) light fixtures on both walls by the pool table,3)light fixture in the basement office,4) multiple open junction boxes in the basement ceiling • _ i � r Printed on 01/08/2021 @ 17:40 Page 8 of 11 STATUS CODE DESCRIPTION - A FAI L 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including, but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered, breached or penetrated. Records of inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel,access door,ceiling tile or similar movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector: BROCK WELIVER-Comments:Ceiling tiles in the back room by the exit need to be replaced FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10.Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector: BROCK WELIVER-Comments: Fire Extinguisher is missing and one needs to be in place.This in part of the Do Not Occupy order.****This item has been corrected as of 1630 hours on 1-8-2021 GENERAL NOTES BROCK WELIVER-01/08/2021 @ 17:26 Fire Alarm: N/A BROCK WELIVER-01/08/2021 @ 17:26 Fire Sprinkler:N/A Printed on 01/08/2021 @ 17:40 Page 9 of 11 GENERAL NOTES BROCK WELIVER-01/08/2021 @ 17:27 Fire Extinguisher: missing during inspection.This item was corrected as of 1630 on 1-8- 2021 BROCK WELIVER-01/08/2021 @ 17:30 Do Not Occupy was posted on this address at 1500 hours on 1-8-2021 for the following reasons: 1)bolt locks on the back door&2)lack of fire extinguisher.As of 1630 hours on 1-8-2021 both of these items had been corrected and verified by Lt. Brock Weliver of WFR and the Do Not Occupy was removed. BROCK WELIVER-01/08/2021 @ 17:35 Howard Allen and his employee were present for the inspection of the building. BROCK WELIVER-01/08/2021 @ 17:35 Occupant Load was calculated at 65 BROCK WELIVER-01/08/2021 @ 17:36 Inspection Fee=$80 BROCK WELIVER-01/08/2021 @ 17:36 Invoice Contact/Todd Goodson/319-529-4287 REINSPECTION DATE 01/22/2021 CONTACT SIGNATURE Howard Allen Contact Refused Refusal Reason:Not required due to Covid INSPECTOR SIGNATURE BROCK WELIVER Signed on:01/08/2021 @ 17:38 • Printed on 01/08/2021 @ 17:40 Page 10 of 11