Loading...
HomeMy WebLinkAbout2450 CROSSROADS BLVD r INVOICE DATE DUE DATE INVOICE# TOTAL DUE /et 'Ii L / +rirso► ,r" 02/09/2021 03/15/2021 2021-00000202 $235.00 Customer#: 13032 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable CROSSROADS 12 THEATRES 715 Mulberry St 2450 CROSSROADS BLVD WATERLOO, IA 50703 WATERLOO,IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-2450 CROSSROADS BLVD-2-2-21 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price INSPECTION 50,000 $225.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 13032 02/09/2021 03/15/2021 2021-00000202 $235.00 Less Prepayment $0.00 Total Due—> $235.00 City of Waterloo tER( ATERLOO FIRE RESCUE ?$D5Z INSPECTION REPORT : VI MARCUS THEATERS,2450 CROSSROADS BLVD,BLDG 2450 CROSSROADS BLVD,WATERLOO IA 50702 4440 DETAILS Inspection Date:02/02/2021 I Inspection Type:Annual Inspection(1Yr) I Inspection Number:4238 I Shift: N/A i Station: N/A Unit: N/A I Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A I Fee:$235.00 STATUS CODE DESCRIPTION FAR. 506.2-Key box maintenance The operator of the building shall immediately notify the fire code official and provide the new key where a lock is changed or rekeyed.The key to such lock shall be secured in the key box. Inspector:JEFF SIEBEL-Comments:Install current key for all doors including key to new lock on door to access fire sprinkler riser. FAR. 509.1 -Identification Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems,sprinkler risers and valves,or other fire detection,suppression or control elements shall be identified for the use of the fire department.Approved signs required to identify fire protection equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. Inspector:JEFF SIEBEL-Comments: Install permanent signage,red with white engraved letters stating"Fire Sprinkler Riser Room":A.On outside of door with a keyed entry lock.B.On curtain as agreed to by fire sprinkler riser. FAR. 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments: Repair egress lights:A.Above fire alarm panel B. Hallway by Theater 2 and mop room.C.Theater 6 by row F near and far. D.egress light in hall by theater 7/8.E.Ultra theater by G/H near hanging by wires. F. Egress light at top of stairs in loft. FAR. 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments: Repair exit lights:A.exit light front east exit. B.ear theater 3 and above exit doors in hall.C.Theater 6 by row D.D.Theater 7 row D far and near. E.Theater 9 by Row D. F.Above door to Theater 2 from upstairs. Printed on 02/05/2021 @ 13:48 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 604.4.2-Records Records of the inspection,testing and maintenance of emergency and standby power systems shall include the date of service,name of the servicing technician,a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken.Such records shall be maintained. Inspector:JEFF SIEBEL-Comments:Provide documentation of testing of all emergency egress and exit lights with all discrepancies corrected.(it may be helpful to number lights). FAIL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including, but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered,breached or penetrated. Records of inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel,access door,ceiling tile or similar movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile in theater 12 and close ceiling tile hatch upstairs by#11 FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor testing,and maintenance Inspector:JEFF SIEBEL-Comments:provide current annual fire alarm inspection testing report with all discrepancies corrected. 105 days overdue.Complete immediately.Contractor must submit online to the compliance engine. GENERAL NOTES JEFF SIEBEL-02/05/2021 @ 13:42 Hood Cleaning 8/14/20.Due 2/13/21 JEFF SIEBEL-02/05/2021 @ 13:43 Annual Fire Sprinkler 12/17/20 by Tri State. JEFF SIEBEL-02/05/2021 @ 13:43 Annual Inspection$235 Printed on 02/05/2021 @ 13:48 Page 2 of 3 REINSPECTION DATE 03/04/2021 CONTACT SIGNATURE Dayton D �// Signed on:02/05/2021 @ 13:41 y INSPECTOR SIGNATURE JEFF SIEBEL Signed on:02/05/2021 @ 13:42 1,, QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/05/2021 @ 13:48 Page 3 of 3