Loading...
HomeMy WebLinkAbout1050 SOUTHTOWN DR INVOICE DATE DUE DATE INVOICE# TOTAL DUE 4111 '`r:►= 02/09/2021 03/15/2021 2021-00000198 $610.00 (erloo �o Customer#: 4746 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HOME DEPOT 715 Mulberry St 3207 GREY HAWK COURT WATERLOO, IA 50703 SUITE 200 CARLSBAD, CA 92010 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1050 SOUTHTOWN DR-1-15-21 FOR BILLING INQUIRY: (319)291-4323 L Description: ! Total Price INSPECTION 100,000 $600.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4746 02/09/2021 03/15/2021 2021-00000198 $610.00 Less Prepayment $0.00 Total Due—* $610.00 City of Waterloo f ` ATERLOO FIRE ESCUE APT Sao INSPECTION REPORT17 �' , HOME DEPOT, 1050 SOUTHTOWN DR,BLDG 1050 SOUTHTOWN DR, WATERLOO IA 50702 / DETAILS Inspection Date:01/15/2021 I Inspection Type:Annual Inspection(1Yr) I Inspection Number:4124 i Shift: N/A Station: N/A I Unit: N/A I Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A I Fee:$610.00 STATUS CODE DESCRIPTION FAIL 1010.1.3-Door opening force The force for pushing or pulling open interior swinging egress doors,other than fire doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors,as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force. Inspector:JEFF SIEBEL-Comments:repair outside garden center NE exit gate. Must open with less than 15#force. FAIL 1011.12.2-Roof access Where a stairway is provided to a roof,access to the roof shall be provided through a penthouse complying with Section 1510.2 of the International Building Code. Exception:In buildings without an occupied roof,access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet(1.5 mA2)in area and having a minimum dimension of 2 feet(610 mm). Inspector:JEFF SIEBEL-Comments:Install"Roof Access Sign"on door. FAIL 5.2.1.1.E-Missing Escutcheons and coverplates for recessed,flush,and concealed sprinklers shall be escutcheons replaced if found missing during the inspection. Inspector:JEFF SIEBEL-Comments:replace missing escutcheon in roof access room and repair ceiling obstructing the fire sprinkler head FAIL 604.4.2-Records Records of the inspection,testing and maintenance of emergency and standby power systems shall include the date of service,name of the servicing technician,a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken.Such records shall be maintained. Inspector:JEFF SIEBEL-Comments:provide documentation of testing of all emergency egress and exit lights with all deficiencies corrected. Printed on 01/19/2021 @ 11:39 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 604.6-Emergency lighting Emergency lighting shall be inspected and tested in accordance with Sections 604.6.1 equipment through 604.6.2.1. Inspector:JEFF SIEBEL-Comments:Provide annual emergency generator load bank test and engine service. FAIL 605.3-Working space and A working space of not less than 30 inches(762 mm)in width,36 inches(914 mm)in clearance depth and 78 inches(1981 mm)in height shall be provided in front of electrical service equipment.Where the electrical service equipment is wider than 30 inches (762 mm),the working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access openings into attics or under-floor areas which provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments:remove obstructions to electric panel in computer room.maintain a minimum of 36"clearance. FAIL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including, but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered,breached or penetrated. Records of inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel,access door,ceiling tile or similar movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile in computer room. FAIL 906.6-Unobstructed and Portable fire extinguishers shall not be obstructed or obscured from view. In rooms unobscured or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of extinguishers. Inspector:JEFF SIEBEL-Comments: remove obstructions to fire extinguisher by potting soil. Maintain a minimum of 36"to and around fire extinguisher. GENERAL NOTES JEFF SIEBEL-01/19/2021 @ 10:58 Annual Inspection$610 Printed on 01/19/2021 @ 11:39 Page 2 of 3 GENERAL NOTES JEFF SIEBEL-01/19/2021 @ 11:27 review current storage height. Reduce storage to maximum height allowed by fire sprinkler design. JEFF SIEBEL-01/19/2021 @ 11:28 provide opportunity to inspect receiving exit door. Replace fading Fire Door Do Not Block signs by next year. JEFF SIEBEL-01/19/2021 @ 11:29 Annual Fire Sprinkler 7/21/20 RNL inc JEFF SIEBEL-01/19/2021 @ 11:30 Annual private hydrant by RNL Services 7/21/20 JEFF SIEBEL-01/19/2021 @ 11:30 Annual fire alarm by Summit 6/29/20 REINSPECTION DATE 02/05/2021 CONTACT SIGNATURE Karl Pold k c, Signed on:01/19/2021 @ 11:24 r)( s>/ INSPECTOR SIGNATURE JEFF SIEBEL Signed on:01/19/2021 @ 11:24 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 01/19/2021 @ 11:39 Page 3 of 3