Loading...
HomeMy WebLinkAbout600 STEPHEN AVE j , - INVOICE DATE DUE DATE INVOICE# TOTAL DUE C O2/09/2021 03/15/2021 2021-00000187 $80.00 irmioirfoCustomer#: 3456 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BLESSED SACRAMENT 715 Mulberry St 650 STEPHAN AV WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-600 STEPHEN AVE-2-4-21 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price. INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 3456 02/09/2021 03/15/2021 2021-00000187 $80.00 Less Prepayment $0.00 Total Due--* $80.00 City of Waterloo 3L1\,5(41' WATERLOG FIRE RESCUE LI4,,x °° ,;‘,P INSPECTION REPORT 4 BLESSED SACRAMENT EARLY CHILDHOOD CENTER,600 STEPHENAVE,BLDG 600 STEPHAN42tZta0 AVE,WATERLOO IA 50701 DETAILS Inspection Date:02/04/2021 1 Inspection Type:Annual Inspection(1Yr) I Inspection Number:3916 I Shift: N/A Station: N/A I Unit: N/A 1 Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 403.10.2.1.1 -First emergency The first emergency evacuation drill of each school year shall be conducted within 10 evacuation drill days of the beginning of classes. Inspector:JEFF SIEBEL-Comments: provide documentation of fire drills for each age level at different times of the day. FAIL 605.3.1 -Labeling Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating ELECTRICAL ROOM or similar approved wording.The disconnecting means for each service,feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident. Inspector:JEFF SIEBEL-Comments: Install permanent label stating"Electrical Room" on electrical room in the butterfly room. Remove all obstructions to electrical panel and maintain a minimum of 36"clearance at all times. FAIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Inspector:JEFF SIEBEL-Comments:remove extension cords from room 114 FAIL 703.2.3-Door operation Swinging fire doors shall close from the full-open position and latch automatically. The door closer shall exert enough force to close and latch the door from any partially open position. Inspector:JEFF SIEBEL-Comments:Adjust double doors by room 107. Doors must completely self-close and latch. GENERAL NOTES JEFF SIEBEL-02/08/2021 @ 08:30 Annual Inspection$80 Printed on 02/08/2021 @ 08:53 Page 1 of 2 J . GENERAL NOTES JEFF SIEBEL-02/08/2021 @ 08:48 annual fire alarm Hawkeye 11/2/20 JEFF SIEBEL-02/08/2021 @ 08:49 Hood cleaning 11/2/20 REINSPECTION DATE 03/04/2021 CONTACT SIGNATURE Aaron Becker nn ` Signed on:02/08/2021 @ 08:51 V` (.151 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:02/08/2021 @ 08:51 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 02/08/2021 @ 08:53 Page 2 of 2