COMMERCIAL INSPECTION-508 BROADWAY ST-2-18-21 FOR BILLING INQUIRY: (319)291-4323
L Description I Total Price j
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
20748 03/23/2021 04/26/2021 2021-00000241 $80.00
Less Prepayment $0.00
Total Due $80.00
City of Waterloo
q Si
L ,ER,...
WATERLOO FIRE RESCUE , ..e. 0
rid
INSPECTION REPORT
PRIME MART,508 BROADWAY ST,BLDG 508 BROADWAY ST,WATERLOO IA 50703
DETAILS
Inspection Date:02/18/2021 I Inspection Type:Annual Inspection(1Yr) Inspection Number:4229 I Shift: N/A Station: N/A
Unit: N/A I Lead Inspector:JEFF SIEBEL Other Inspectors: N/A
STATUS CODE DESCRIPTION
FAIL 305.1 -Clearance from Clearance between ignition sources,such as luminaires,heaters,flame-producing
ignition sources devices and combustible materials,shall be maintained in an approved manner.
Inspector:JEFF SIEBEL-Comments:remove storage against furnace. Repeat violation.
Maintain a minimum of 36"clearance to and around furnace.
s — Warns odki,
Pitt-4[1::iq „ 1 11.11 I 'TA' 2114ii
i f
-t
Printed on 02/18/2021 @ 15:12
Page 1 of 4
STATUS CODE DESCRIPTION
FAIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring.
Extension cords and flexible cords shall not be affixed to structures,extended
through walls,ceilings or floors,or under doors or floor coverings,nor shall such
cords be subject to environmental damage or physical impact. Extension cords shall
be used only with portable appliances.
Inspector:JEFF SIEBEL-Comments:remove extension cord from ceiling and frozen
` y, i?rrlf,,,:; '-'11;;-::;'''',:----4- 1--e ---- -, _, -- cocktail freezer.freezer must plug directly into permanent outlet.
C
�
: = -
9
,
i
`` vice,..- .; --‘r -,=,,---4.,-,---_,.
► S j� � � .k4�i�i� �'SFa�/3 /
FAIL 605.7-Appliances Electrical appliances and fixtures shall be tested and listed in published reports of
inspected electrical equipment by an approved agency and installed and maintained
in accordance with all instructions included as part of such listing.
Inspector:JEFF SIEBEL-Comments:2 red bull coolers must plug directly into
permanent wall outlet not a power strip. Install permanent power with proper
permits and inspections.Repeat offense.
Printed on 02/18/2021 @ 15:12
Page 2 of 4
STATUS CODE DESCRIPTION
FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall
be allowed to be once every 3 years for dry-chemical or halogenated agent portable
fire extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1. Electronic
monitoring shall confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic
monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be
installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic
monitoring devices and supervisory circuits shall be tested every 3 years when
extinguisher maintenance is performed.2.5.A written log of required hydrostatic
test dates for extinguishers shall be maintained by the owner to verify that
hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3,
portable fire extinguishers shall be permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments: provide annual inspection for fire extinguishers.
GENERAL NOTES
JEFF SIEBEL-02/18/2021 @ 15:06 annual inspection fee$80
JEFF SIEBEL-02/18/2021 @ 15:07 correct all repeat violations before re-inspection to avoid$100 re-inspection fee.
REINSPECTION DATE
03/15/2021
CONTACT SIGNATURE
Shahid Chatdren � f J.
Signed on:02/18/2021 @ 15:10 ^
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:02/18/2021 @ 15:10
Printed on 02/18/2021 @ 15:12