Loading...
HomeMy WebLinkAbout250 ANSBOROUGH AVE ��".��' INVOICE DATE DUE DATE INVOICE# TOTAL DUE Ill\____ '`I 1 � 1 �'gr 03/23/2021 04/26/2021 2021-00000238 $80.00 OVVAMIS etr Customer#: 20789 Please Make Check Payable and Remit To: City of Waterloo A TTN: City Clerk/Accounts Receivable CATTLE CONGRESS PAVILION 715 Mulberry St 257 ANSBOROUGH AV WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-250 ANSBOROUGH AVE-2-10-21 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 20789 03/23/2021 04/26/2021 2021-00000238 $80.00 Less Prepayment $0.00 Total Due—* $80.00 City of Waterloo ERLOO FIRE RESCUE � AC I WAT INSPECTION REPORT NATIONAL CATTLE CONGRESS PAVILLION,250 ANSBOROUGH AVE,BLDG 250 ANSBOROUGH AVE,WATERLOO/A 50701 424;0 DETAILS Inspection Date:02/10/2021 I Inspection Type:Annual Inspection(1Yr) I Inspection Number:4924 I Shift: N/A i Station: N/A Unit: N/A j Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A I Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:JEFF SIEBEL-Comments:Remove hanging cable from outside of exit discharge from North East exit. Remove snow when ice from all exit doors and exit paths FAIL 1031.3-Obstructions A means of egress shall be free from obstructions that would prevent its use, including the accumulation of snow and ice. Inspector:JEFF SIEBEL-Comments:Immediately remove snow and ice from in front of Northeast and Southwest exit door paths.Currently doors were snowed shut and being dug it out.Maintain clear exit path at all times. FAIL 507.5.5-Clear space around A 3-foot(914 mm)clear space shall be maintained around the circumference of fire hydrants hydrants,except as otherwise required or approved. Inspector:JEFF SIEBEL-Comments:Immediately remove all snow and ice obstructions around fire hydrant. FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:Repair egress/exit light by Northwest exit door Printed on 02/122021 @ 07:14 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 605.3-Working space and A working space of not less than 30 inches(762 mm)in width,36 inches(914 mm)in clearance depth and 78 inches(1981 mm)in height shall be provided in front of electrical service equipment.Where the electrical service equipment is wider than 30 inches (762 mm),the working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access openings into attics or under-floor areas which provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments: Remove all obstructions to electrical panel. Maintain a minimum of 36 inch clearance at all times FAIL 605.7-Appliances Electrical appliances and fixtures shall be tested and listed in published reports of inspected electrical equipment by an approved agency and installed and maintained in accordance with all instructions included as part of such listing. Inspector:JEFF SIEBEL-Comments: Provide documentation of dryer vent cleaning. There is lint hanging out of pipe. GENERAL NOTES JEFF SIEBEL-02/12/2021 @ 07:13 Annual inspection$80 REINSPECTION DATE 03/11/2021 CONTACT SIGNATURE Jim Koch C cl Signed on:02/12/2021 @ 07:09 • INSPECTOR SIGNATURE JEFF SIEBEL Signed on:02/12/2021 @ 07:09 Printed on 02/12/2021 @ 07:14 Page 2 of 3