COMMERCIAL INSPECTION- 1315 E SAN MARNAN DR- 5-7-21 FOR BILLING INQUIRY: (319)291-4323
L Description I Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
4712 05/26/2021 06/30/2021 2021-00000250 $80.00
Less Prepayment $0.00
Total Due $80.00
City of Waterloo
•
ATERLOO FIRE SCUE
INSPECTION REPORT �
OLIVE GARDEN, 1315 E SAN MARNAN DR,BLDG 1315 E SAN MARNAN DR,WATERLOO IA
50702 42440
DETAILS
Inspection Date:05/07/2021 I Inspection Type:Annual Inspection(1 Yr) I Inspection Number:5608 I Shift: N/A Station: N/A
Unit: N/A I Lead Inspector:JEFF SIEBEL Other Inspectors: N/A I Fee:$80.00
STATUS CODE DESCRIPTION
FAIL 1010.1.3-Door opening force The force for pushing or pulling open interior swinging egress doors,other than fire
doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force
required to retract latch bolts or disengage other devices that hold the door in a
closed position. For other swinging doors,as well as sliding and folding doors,the
door latch shall release when subjected to a 15-pound(67 N)force.The door shall be
set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a
full-open position when subjected to a 15-pound(67 N)force.
Inspector:JEFF SIEBEL-Comments:provide opportunity for fire inspector to test
doors.
FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments:repair exit/egress light southwest corner of dining
FAIL 605.6-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers
conditions shall be provided for all switch and electrical outlet boxes.
Inspector:JEFF SIEBEL-Comments:replace missing light covers in walk-in cooler.
Printed on 05/10/2021 @ 11:59
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction, including,
but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers,
floors,fire-resistive coatings and sprayed fire-resistant materials applied to
structural members and fire-resistant joint systems,shall be maintained.Such
elements shall be visually inspected by the owner annually and properly repaired,
restored or replaced where damaged,altered, breached or penetrated. Records of
inspections and repairs shall be maintained.Where concealed,such elements shall
not be required to be visually inspected by the owner unless the concealed space is
accessible by the removal or movement of a panel,access door,ceiling tile or similar
movable entry to the space.Openings made therein for the passage of pipes,
electrical conduit,wires,ducts,air transfer openings and holes made for any reason
shall be protected with approved methods capable of resisting the passage of smoke
and fire.Openings through fire-resistance-rated assemblies shall be protected by
self-or automatic-closing doors of approved construction meeting the fire protection
requirements for the assembly.
Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile by ice machine.
FAIL 904.12.6.2-Extinguishing Automatic fire-extinguishing systems shall be serviced at least every six months and
system service after activation of the system. Inspection shall be by qualified individuals,and a
certificate of inspection shall be forwarded to the fire code official upon completion.
Inspector:JEFF SIEBEL-Comments:Provide current semi-annual kitchen hood fire
suppression inspection report with all discrepancies corrected. Report is overdue
and expiree report lists discrepancies that must be corrected.
FAIL 906.7-Hangers and brackets Hand-held portable fire extinguishers, not housed in cabinets,shall be installed on
the hangers or brackets supplied. Hangers or brackets shall be securely anchored to
the mounting surface in accordance with the manufacturer's installation instructions.
Inspector:JEFF SIEBEL-Comments:properly mount K-guard extinguisher by office.
GENERAL NOTES
JEFF SIEBEL-05/10/2021 @ 11:57 annual inspection $80
REINSPECTION DATE
05/27/2021
Printed on 05/10/2021 @ 11:59
Page 2 of 3
CONTACT SIGNATURE
Christina Brainard
Signed on:05/10/2021 @ 11:57 cc-' '
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:05/10/2021 @ 11:57 t
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224