Loading...
HomeMy WebLinkAbout905 FRANKLIN ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE /4!' rilL r;, 05/26/2021 06/30/2021 2021-00000257 $80.00 Wirt .010.1 Customer#: 10918 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable PEOPLES COMMUNITY HEALTH CLINIC 715 Mulberry St 905 FRANKLIN ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-905 FRANKLIN ST- 5-18-21 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price INSPECTION 1 HH $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 10918 05/26/2021 06/30/2021 2021-00000257 $80.00 Less Prepayment $0.00 Total Due—* $80.00 City of Waterloo WATERLOO FIRE RESCUE P1 E L0a INSPECTION REPORT PEOPLE'S COMMUNITY HEALTH CLINIC,905 FRANKLIN ST,BLDG 905 FRANKLIN ST WATERLOO IA 50703 DETAILS Inspection Date:05/18/2021 I Inspection Type:Annual Inspection(1Yr) ; Inspection Number:6008 I Shift: N/A ! Station: N/A I Unit:324-Fire Marshal ! Lead Inspector:BROCK WELIVER I Other Inspectors:JEFF SIEBEL I Fee:$80.00 STATUS CODE DESCRIPTION FAIL 315.3.1 -Ceiling clearance Storage shall be maintained 2 feet(610 mm)or more below the ceiling in nonsprinklered areas of buildings or not less than 18 inches(457 mm)below sprinkler head deflectors in sprinklered areas of buildings. Inspector: BROCK WELIVER-Comments:2nd Floor-Custodial Closet. Maintain storage as described above.This item was fixed during the inspection FAIL 5303.5.3-Securing Compressed gas containers,cylinders and tanks shall be secured to prevent falling compressed gas containers, caused by contact,vibration or seismic activity.Securing of compressed gas cylinders and containers,cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints.2. Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks.3. Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers'warehouses not accessible to the public. Nesting shall be allowed provided the nested containers,cylinders or tanks,if dislodged,do not obstruct the required means of egress.4.Securing of compressed gas containers, cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use. Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Inspector: BROCK WELIVER-Comments: Urgent Care-Room 3,02 bottles were found loosely stored in this area. Ensure that all bottles,whether full or empty,are properly stored as described above. FAIL 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination with Sections 1008.3 and 1104.5.1. Inspector: BROCK WELIVER-Comments: 1st Floor-Main Entry Lobby,just to the left as you walk in the entry door,egress light was out when tested Printed on 05/19/2021 @ 08:33 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BROCK WELIVER-Comments:2nd Floor-PEDS,Christmas lights were plugged in to an amplifier.Temporary lighting such as Christmas lights are given approximately 90 days for display purposes. FAIL 605.7-Appliances Electrical appliances and fixtures shall be tested and listed in published reports of inspected electrical equipment by an approved agency and installed and maintained in accordance with all instructions included as part of such listing. Inspector: BROCK WELIVER-Comments:2nd Floor-Break Room, microwave was plugged into a power tap.2nd Floor-Medical Records, mini fridge was plugged into a power tap. Ensure that all larger appliances with motors and compressors are plugged directly into wall outlets. FAIL 609.2-Where required A Type I hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Exception:A Type I hood shall not be required for an electric cooking appliance where an approved testing agency provides documentation that the appliance effluent contains 5 mg/m^3 or less of grease when tested at an exhaust flow rate of 500 cfm(0.236 m^3/s)in accordance with UL 710B. Inspector: BROCK WELIVER-Comments:2nd Floor-Break Room,ensure that no sautéing or frying is conducted on this stove.If you would like to use the stove for this purpose,then a Type 1 hood shall be installed as described above.Corrective Action:provide a sign above the stove at states: No sauteing or frying allowed. FAIL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including, but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered, breached or penetrated. Records of inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel,access door,ceiling tile or similar movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector: BROCK WELIVER-Comments: 1st Floor-janitors Closet,penetration in drywall needs to be fire caulked. 1st Floor-Pharmacy,2 ceiling tiles were missing near the customer help window. Printed on 05/19/2021 @ 08:33 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 703.2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with NFPA 80.Where allowed by the fire code official,the application of field-applied labels associated with the maintenance of opening protectives shall follow the requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. Inspector: BROCK WELIVER-Comments:2nd Floor-IT Room, rating tags on fire doors were found to be painted,ensure that the tags are legible. FAIL 703.2.2-Hold-open devices Hold-open devices and automatic door closers,where provided,shall be maintained. and closers During the period that such device is out of service for repairs,the door it operates shall remain in the closed position. Inspector:BROCK WELIVER-Comments:Discontinue the practice of using door wedges or objects to prop doors open. Multiple fire rated doors were found to be propped open. If doors are desired to be left in the open position,then hold-open devices should be installed that are connected to the fire alarm system. GENERAL NOTES BROCK WELIVER-05/19/2021 @ 08:22 Fire Alarm:current,serviced by Hawkeye Alarm&Signal 2-3-2021. Report has been uploaded into The Compliance Engine. 1 Trouble Alarm showing on the system. BROCK WELIVER-05/19/2021 @ 08:23 Fire Sprinkler:current,serviced by Black Hawk Sprinkler 5-10-2021. Report was just uploaded into The Compliance Engine BROCK WELIVER-05/19/2021 @ 08:24 Fire Extinguishers:current,serviced by Superior Fire Protection Equipment-Feb 2021 BROCK WELIVER-05/19/2021 @ 08:25 Drop Doors:current,serviced by Christie Door Company 2-3-2021. Reports are on file in maintenance logs BROCK WELIVER-05/19/2021 @ 08:26 Inspection Fee=$80 BROCK WELIVER-05/19/2021 @ 08:28 Invoice Contact/Dan Adams/319-874-3000 BROCK WELIVER-05/19/2021 @ 08:31 Due to ongoing community health concerns,you may take photographs of the corrections made and email them to the email provided on this report Printed on 05/19/2021 @ 08:33 Page 3 of 4 REINSPECTION DATE 06/18/2021 CONTACT SIGNATURE Dan Adams-Maintenance Contact Refused Refusal Reason: Not required due to Covid-19 INSPECTOR SIGNATURE BROCK WELIVER Signed on:05/19/2021 @ 08:33 QUESTIONS ABOUT YOUR INSPECTION? BROCK WELIVER brock.weliver@waterloo-ia.org 3192914460 Printed on 05/19/2021 @ 08:33 Page 4 of 4