Loading...
HomeMy WebLinkAbout1976 FRANKLIN ST �;�"' INVOICE DATE DUE DATE INVOICE# TOTAL DUE /Ii1 1 � '1�'\�I��'-` 05/26/2021 06/30/2021 2021-0000 iF 0254 $80.00 Customer#: 22784 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable YESWAY 715 Mulberry St 138 CONANT ST WATERLOO, IA 50703 BEVERLY,MA 01915 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1976 FRANKLIN ST- 5-4-21 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 22784 05/26/2021 06/30/2021 2021-00000254 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo WATERLOO FIRE RESCUE40.4,0 INSPECTION REPORT YESWAY, 1976 FRANKLIN ST,BLDG 1976 FRANKLIN ST,WATERLOO/A 50703 DETAILS Inspection Date:05/04/2021 I Inspection Type:Annual Inspection(1Yr) I Inspection Number:4439 I Shift: N/A I Station: N/A Unit: N/A I Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A I Fee:$80.00 STATUS CODE DESCRIPTION FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair egress/exit sign above main front door. FAIL 605.3-Working space and A working space of not less than 30 inches(762 mm)in width,36 inches(914 mm)in clearance depth and 78 inches(1981 mm)in height shall be provided in front of electrical service equipment.Where the electrical service equipment is wider than 30 inches (762 mm),the working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access openings into attics or under-floor areas which provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments:remove obstructions to all electric panels. maintain a minimum of 36"clearance.Obey signage in place. FAIL 605.6-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers conditions shall be provided for all switch and electrical outlet boxes. Inspector:JEFF SIEBEL-Comments:install missing breaker or listed blank in electrical panel A. Printed on 05/05/2021 @ 09:27 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1. Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:fire extinguishers due for annual service. GENERAL NOTES JEFF SIEBEL-05/05/2021 @ 07:46 Annual fee$80 REINSPECTION DATE 05/25/2021 CONTACT SIGNATURE Shelly Knott Signed on:05/05/2021 @ 09:21 �t 4 -- Ci_ INSPECTOR SIGNATURE JEFF SIEBEL Signed on:05/05/2021 @ 09:21 Printed on 05/05/2021 @ 09:27 Page 2 of 3