Loading...
HomeMy WebLinkAbout2841 CROSSROADS BLVD (2) INVOICE DATE DUE DATE INVOICE# TOTAL DUE ter... 05/26/2021 06/30/2021 2021-00000282 $80.00 Customer#: 22674 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable AT&T AND SPRINT MOBILE 715 Mulberry St 2841 CROSSROADS BLVD SUITE C WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-2841 CROSSROADS BLVD. -4-12-21 FOR BILLING INQUIRY: (319)291-4323 Description Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 22674 05/26/2021 06/30/2021 2021-00000282 $80.00 Less Prepayment $0.00 Total Due —> $80.00 City of Waterloo WATERLOO FIRE RESCUE r 44p.„RLo0 INSPECTION REPORT AT&T&SPRINT MOBILE,2841 CROSSROADS BLVD,BLDG 2841 CROSSROADS BLVD, )// WATERLOO/A 50702 DETAILS Inspection Date:04/12/2021 Inspection Type:Annual Inspection(1Yr) I Inspection Number:5770 I Shift: N/A Station: N/A Unit: N/A I Lead Inspector:JEFF SIEBEL ; Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 505.1 -Address identification New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property.Address identification characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 1/2(12.7 mm). Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector:JEFF SIEBEL-Comments:replace faded and peeling number on building. FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments: Repair egress//exit lights:A. Front door B. Back of Retail area.C. Rear exit. Printed on 04/26/2021 41 09:40 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:JEFF SIEBEL-Comments:properly mount electrical boxes by desk. i tit/ `y FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1. Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments: provide annual service and properly mount fire extinguisher 4"to 5 feet above floor in an accessible area. GENERAL NOTES JEFF SIEBEL-04/26/2021 @ 09:39 annual inspection$80 Printed on 04/26/2021 @ 09:40 Page 2 of 3 GENERAL NOTES JEFF SIEBEL-04/26/2021 @ 09:40 provide corrections to avoid re-inspection fees.Several attempts made to obtain contact information since 4/12 REINSPECTION DATE 05/13/2021 CONTACT SIGNATURE Jake Williams (C/i Signed on:04/26/2021 @ 09:37 h y )21 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:04/26/2021 @ 09:37 fr QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 04/26/2021 @ 09:40 Page 3 of 3