HomeMy WebLinkAbout3910 UNIVERSITY AVE (2) INVOICE DATE DUE DATE INVOICE# TOTAL DUE
/-1�. riit; 05/26/2021 06/30/2021 2021-00000278 $80.00
4'erloo �o
Customer#: 21006 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
WALGREENS DRUG STORE#3590 715 Mulberry St
3910 UNIVERSITY AV WATERLOO, IA 50703
WATERLOO, IA 50701
Amount Enclosed.
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL INSPECTION -3910 UNIVERSITY AVE- 04-16-21 FOR BILLING INQUIRY: (319)291-4323
L Description I Total Price J
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
21006 05/26/2021 06/30/2021 2021-00000278 $80.00
Less Prepayment $0.00
Total Due $80.00
City of Waterloo
icsji.„0
WATERLOO FIRE RESCUE „ER(°
INSPECTION REPORT
WALGREENS,3910 UNIVERSITY AVE,BLDG 3910 UNIVERSITY AVE,WATERLOO IA 50701 42410
DETAILS
Inspection Date:04/16/2021 Inspection Type:Annual Inspection(1Yr) I Inspection Number:4567 I Shift: N/A j Station: N/A
Unit: N/A I Lead Inspector:JEFF SIEBEL ; Other Inspectors: N/A I Fee:$80.00
STATUS CODE DESCRIPTION
R
i
FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector:JEFF SIEBEL-Comments:allow fire inspector opportunity to test side door
by fire sprinkler riser.
FAIL 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance
illumination with Sections 1008.3 and 1104.5.1.
Inspector:JEFF SIEBEL-Comments:repair egress light above aisle 8 hair accessories.
FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments:repair exit light by fire sprinkler riser.
FAIL 605.3-Working space and A working space of not less than 30 inches(762 mm)in width,36 inches(914 mm)in
clearance depth and 78 inches(1981 mm)in height shall be provided in front of electrical
service equipment.Where the electrical service equipment is wider than 30 inches
(762 mm),the working space shall be not less than the width of the equipment.
Storage of materials shall not be located within the designated working space.
Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access
openings into attics or under-floor areas which provide a minimum clear opening of
22 inches(559 mm)by 30 inches(762 mm).
Inspector:JEFF SIEBEL-Comments: Remove obstructions to electrical panel and fire
sprinkler riser.maintain a minimum of 36"clearance at all times.
Printed on 04/19/2021 @ 10:03
Page 1 of 3
STATUSDESCRIPTION
CODE
FAIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring.
Extension cords and flexible cords shall not be affixed to structures,extended
through walls,ceilings or floors,or under doors or floor coverings, nor shall such
cords be subject to environmental damage or physical impact. Extension cords shall
be used only with portable appliances.
Inspector:JEFF SIEBEL-Comments:Remove extension cord to new immunization
room. Install permanent power with permitse:
and inspections.
FAIL 903.3.3-Obstructed locations A sprinklers
activationutomatic or obstruct theshall waterbe distributioninstalledwithdue pattern.regard Automatictoobstructions sprinklers shallwilldelay
be
ao , la ,b , oion standsthat or
equipment inst lled in thatorunder exceecds 4 feetveredkiosks(1219 dispmm)inys width.ooths Notc lessncess than a 3-foot(914.mm)
clearance shall be maintained between automatic sprinklers and the top of piles of
--;" * 1 . IA-- � - combustible fibers. Exception: Kitchen equipment under exhaust hoods protected
r;:: with a fire-extinguishing system in accordance with Section 904.
' „
� � Inspector:JEFF SIEBEL-Comments:New walls for immunization area are less than 18
-_-, ,.,, below fire sprinkler heads and the protection pattern will be obstructed.Contact fire
sprinkler contractor for proper coverage.
FAIL 912.4.2-Clear space around A working space of not less than 36 inches(914 mm)in width,36 inches(914 mm)in
connections depth and 78 inches(1981 mm)in height shall be provided and maintained in front of
and to the sides of wall-mounted fire department connections and around the
circumference of free-standing fire department connections,except as otherwise
required or approved by the fire chief.
Inspector:JEFF SIEBEL-Comments:remove obstructions to fire department
connections on outside of building.
GENERAL NOTES
JEFF SIEBEL-04/19/2021 @ 10:02 annual inspection$80
REINSPECTION DATE
05/07/2021
Printed on 04/19/2021 @ 10:03
Page 2 of 3
CONTACT SIGNATURE
Vicki Wheeler e c'j 17
Signed on:04/19/2021 @ 10:01
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:04/19/2021 @ 10:01
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed on 04/19/2021 @ 10:03
Page 3 of 3