Loading...
HomeMy WebLinkAbout3910 UNIVERSITY AVE (2) INVOICE DATE DUE DATE INVOICE# TOTAL DUE /-1�. riit; 05/26/2021 06/30/2021 2021-00000278 $80.00 4'erloo �o Customer#: 21006 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable WALGREENS DRUG STORE#3590 715 Mulberry St 3910 UNIVERSITY AV WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION -3910 UNIVERSITY AVE- 04-16-21 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 21006 05/26/2021 06/30/2021 2021-00000278 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo icsji.„0 WATERLOO FIRE RESCUE „ER(° INSPECTION REPORT WALGREENS,3910 UNIVERSITY AVE,BLDG 3910 UNIVERSITY AVE,WATERLOO IA 50701 42410 DETAILS Inspection Date:04/16/2021 Inspection Type:Annual Inspection(1Yr) I Inspection Number:4567 I Shift: N/A j Station: N/A Unit: N/A I Lead Inspector:JEFF SIEBEL ; Other Inspectors: N/A I Fee:$80.00 STATUS CODE DESCRIPTION R i FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:JEFF SIEBEL-Comments:allow fire inspector opportunity to test side door by fire sprinkler riser. FAIL 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:repair egress light above aisle 8 hair accessories. FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair exit light by fire sprinkler riser. FAIL 605.3-Working space and A working space of not less than 30 inches(762 mm)in width,36 inches(914 mm)in clearance depth and 78 inches(1981 mm)in height shall be provided in front of electrical service equipment.Where the electrical service equipment is wider than 30 inches (762 mm),the working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. Exceptions: 1.Where other dimensions are required or allowed by NFPA 70.2.Access openings into attics or under-floor areas which provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEFF SIEBEL-Comments: Remove obstructions to electrical panel and fire sprinkler riser.maintain a minimum of 36"clearance at all times. Printed on 04/19/2021 @ 10:03 Page 1 of 3 STATUSDESCRIPTION CODE FAIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Inspector:JEFF SIEBEL-Comments:Remove extension cord to new immunization room. Install permanent power with permitse: and inspections. FAIL 903.3.3-Obstructed locations A sprinklers activationutomatic or obstruct theshall waterbe distributioninstalledwithdue pattern.regard Automatictoobstructions sprinklers shallwilldelay be ao , la ,b , oion standsthat or equipment inst lled in thatorunder exceecds 4 feetveredkiosks(1219 dispmm)inys width.ooths Notc lessncess than a 3-foot(914.mm) clearance shall be maintained between automatic sprinklers and the top of piles of --;" * 1 . IA-- � - combustible fibers. Exception: Kitchen equipment under exhaust hoods protected r;:: with a fire-extinguishing system in accordance with Section 904. ' „ � � Inspector:JEFF SIEBEL-Comments:New walls for immunization area are less than 18 -_-, ,.,, below fire sprinkler heads and the protection pattern will be obstructed.Contact fire sprinkler contractor for proper coverage. FAIL 912.4.2-Clear space around A working space of not less than 36 inches(914 mm)in width,36 inches(914 mm)in connections depth and 78 inches(1981 mm)in height shall be provided and maintained in front of and to the sides of wall-mounted fire department connections and around the circumference of free-standing fire department connections,except as otherwise required or approved by the fire chief. Inspector:JEFF SIEBEL-Comments:remove obstructions to fire department connections on outside of building. GENERAL NOTES JEFF SIEBEL-04/19/2021 @ 10:02 annual inspection$80 REINSPECTION DATE 05/07/2021 Printed on 04/19/2021 @ 10:03 Page 2 of 3 CONTACT SIGNATURE Vicki Wheeler e c'j 17 Signed on:04/19/2021 @ 10:01 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:04/19/2021 @ 10:01 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 04/19/2021 @ 10:03 Page 3 of 3