Loading...
HomeMy WebLinkAbout225-229 E 4TH ST INVOICE DATE DUE DATE 1 INVOICE# TOTAL DUE /il/111 '� \ �� k-1�� 06/15/2021 07/30/2021 2021-00000300 $80.00 .0100110.04. Customer#: 22984 Please Make Check Payable and Remit To: City of Waterloo A TTN: City Clerk/Accounts Receivable LOCALS 715 Mulberry St 229 E 4TH ST WATERLOO, IA 50703 WATERLOO,IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-225-229 E 4TH ST- 6-7-21 I FOR BILLING INQUIRY: (319)291-4323 I LDescription 1 Total Price j INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE I DUE DATE CHARGES 22984 06/15/2021 07/30/2021/2021INVOICE# 2021-00000300 $80.00 Less Prepayment $0.00 Total Due--3 $80.00 City of Waterloo --a-a7c64/ WATERLOO FIRE RESCUE R(oo _.-INSPECTION REPORT LOCALS,225-229 E 4TH ST,BLDG 22 -229 E 4TH ST,WATERLOO IA 50703 Inspection Date:06/07/2021 l Inspection Type:Annual Inspection(1Yr) Inspection Number:4564 l Shift: N/A i Station: N/A Unit: N/A l Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair egress/exit lights:A. Kitchen B.West end of bar. FAIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Inspector:JEFF SIEBEL-Comments: remove extension cord from refrigerator in kitchen.The refrigerator must plug directly into the wall outlet. FAIL 605.7-Appliances Electrical appliances and fixtures shall be tested and listed in published reports of inspected electrical equipment by an approved agency and installed and maintained in accordance with all instructions included as part of such listing. Inspector:JEFF SIEBEL-Comments:freezer in basement must plug directly into wall outlet in basement. Remove extension cord. FAIL 609.3.3-Cleaning Hoods,grease-removal devices,fans,ducts and other appurtenances shall be cleaned at intervals as required by Sections 609.3.3.1 through 609.3.3.3. Inspector:JEFF SIEBEL-Comments:Provide current semi-annual kitchen hood exhaust system cleaning inspection report with all discrepancies corrected. Contractor must upload online to the compliance engine. Printed on 06/08/2021 @ 08:55 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 609.3.3.3-Records Records for inspections shall state the individual and company performing the inspection,a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place.Such records shall be completed after each inspection or cleaning and maintained. Inspector:JEFF SIEBEL-Comments: Provide current semi-annual kitchen hood exhaust system cleaning and fire suppression inspection reportswith all discrepancies corrected.Contractor must upload online to the compliance engine. FAIL 904.12.5.2-Class K portable Where hazard areas include deep fat fryers,listed Class K portable fire extinguishers fire extinguishers for deep fat shall be provided as follows: 1. For up to four fryers having a maximum cooking f medium capacity of 80 pounds(36.3 kg)each:one Class K portable fire extinguisher of a minimum 1.5-gallon(6 L)capacity.2. For every additional group of four fryers having a maximum cooking medium capacity of 80 pounds(36.3 kg)each:one additional Class K portable fire extinguisher of a minimum 1.5-gallon(6 L)capacity shall be provided.3. For individual fryers exceeding 6 square feet(0.55 mA2)in surface area:Class K portable fire extinguishers shall be installed in accordance with the extinguisher manufacturer's recommendations. Inspector:JEFF SIEBEL-Comments:properly mount sign above k guard extinguisher in kitchen. FAIL 904.12.6.2-Extinguishing Automatic fire-extinguishing systems shall be serviced at least every six months and system service after activation of the system. Inspection shall be by qualified individuals,and a certificate of inspection shall be forwarded to the fire code official upon completion. Inspector:JEFF SIEBEL-Comments:Provide current semi-annual kitchen hood exhaust system fire suppression inspection report with all discrepancies corrected. Contractor must upload online to the compliance engine. FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1. Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers. Printed on 06/08/2021 @ 08:55 Page 2 of 3 STATUS CODE DESCRIPTION FAIL 906.7-Hangers and brackets Hand-held portable fire extinguishers,not housed in cabinets,shall be the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:properly mount fire extinguisher sitting by dj booth 4"to 5'above the floor. GENERAL NOTES JEFF SIEBEL-06/08/2021 @ 08:49 Annual inspection.$80 REINSPECTION DATE 07/06/2021 CONTACT SIGNATURE Yashpal Saini /� Signed on:06/08/2021 @ 08:52 Y ,„„ci INSPECTOR SIGNATURE JEFF SIEBEL Signed on:06/08/2021 @ 08:52 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 06/08/2021 @ 08:55 Page 3 of 3