COMMERCIAL INSPECTION-3005 UNIVERSITY AVE- 5-5-21 FOR BILLING INQUIRY: (319)291-4323
L Description I Total Price j
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
8212 06/15/2021 07/30/2021 2021-00000294 $80.00
Less Prepayment $0.00
Total Due--> $80.00
City of Waterloo
Vss\
WAIT' 0 FIRE CUE RR%
INSPECTION REPORT
CHASERS LOUNGE,3005 UNIVERSITY AV,BLDG 3005 UNIVERSITY AVE,WATERLOO IA 50701 .4110
DE S
Inspection Date5/05/2021 l`Inspection Type:Annual Inspection(1 Yr) I Inspection Number:4538 Shift: I
pN/A Station:; N/A ;
Unit: N/A I Leac(lnspectjgplEFF SIEBEL ' Other Inspectors: N/A
STATUS CODE DESCRIPTION
FAIL 1010.1.3-Door opening force The force for pushing or pulling open interior swinging egress doors,other than fire
doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force
required to retract latch bolts or disengage other devices that hold the door in a
closed position. For other swinging doors,as well as sliding and folding doors,the
door latch shall release when subjected to a 15-pound(67 N)force.The door shall be
set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a
full-open position when subjected to a 15-pound(67 N)force.
Inspector:JEFF SIEBEL-Comments:repair exit door from outdoor beer garden. Door
must open with less than 15#force.
IL 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance
illumination with Sections 1008.3 and 1104.5.1.
Inspector:JEFF SIEBEL-Comments:repair egress light above pool table.
FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments:Repair exit/egress light:A.above outdoor garden
outside door. B. Egress light above pool table.
Printed on 05/06/2021 @ 07:39
Page 1 of 2
STATUS CODE DESCRIPTION
FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall
be allowed to be once every 3 years for dry-chemical or halogenated agent portable
fire extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1. Electronic
monitoring shall confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic
monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be
installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic
monitoring devices and supervisory circuits shall be tested every 3 years when
extinguisher maintenance is performed.2.5.A written log of required hydrostatic
test dates for extinguishers shall be maintained by the owner to verify that
hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3,
portable fire extinguishers shall be permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers
GENERAL NOTES
JEFF SIEBEL-05/06/2021 @ 07:39 annual inspection$80
REINSPECTION DATE
05/26/2021
CONTACT SIGNATURE
Brian Tressler p,_d /,
Signed on:05/06/2021 @ 07:38
t-tki
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:05/06/2021 @ 07:38