Loading...
HomeMy WebLinkAbout3005 UNIVERSITY AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE A�� I� ��i,�f�l'i� 06/15/2021 07/30/2021 2021-00000294 $80.00 tloer o Customer#: 8212 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable CHASER'S PUB 715 Mulberry St 3 005 UNIVERSITY AV WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-3005 UNIVERSITY AVE- 5-5-21 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price j INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 8212 06/15/2021 07/30/2021 2021-00000294 $80.00 Less Prepayment $0.00 Total Due--> $80.00 City of Waterloo Vss\ WAIT' 0 FIRE CUE RR% INSPECTION REPORT CHASERS LOUNGE,3005 UNIVERSITY AV,BLDG 3005 UNIVERSITY AVE,WATERLOO IA 50701 .4110 DE S Inspection Date5/05/2021 l`Inspection Type:Annual Inspection(1 Yr) I Inspection Number:4538 Shift: I pN/A Station:; N/A ; Unit: N/A I Leac(lnspectjgplEFF SIEBEL ' Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1010.1.3-Door opening force The force for pushing or pulling open interior swinging egress doors,other than fire doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors,as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force. Inspector:JEFF SIEBEL-Comments:repair exit door from outdoor beer garden. Door must open with less than 15#force. IL 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:repair egress light above pool table. FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:Repair exit/egress light:A.above outdoor garden outside door. B. Egress light above pool table. Printed on 05/06/2021 @ 07:39 Page 1 of 2 STATUS CODE DESCRIPTION FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1. Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers GENERAL NOTES JEFF SIEBEL-05/06/2021 @ 07:39 annual inspection$80 REINSPECTION DATE 05/26/2021 CONTACT SIGNATURE Brian Tressler p,_d /, Signed on:05/06/2021 @ 07:38 t-tki INSPECTOR SIGNATURE JEFF SIEBEL Signed on:05/06/2021 @ 07:38 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 05/06/2021 @ 07:39 Page 2 of 2