Loading...
HomeMy WebLinkAbout1104 WASHINGTON ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE „% i ,APT,Q 06/15/2021 07/30/2021 2021-00000299 $80.00 ertoo,. Customer#: 14228 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable KWIK STOP#3 715 Mulberry St 1104 WASHINGTON ST WATERLOO, IA 50703 WATERLOO,IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1104 WASHINGTON ST- 6-1-21 FOR BILLING INQUIRY: (319)291-4323 Description Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 14228 06/15/2021 07/30/2021 2021-00000299 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo , , jq-a/2 y i . 00 FIRE RESCUE INSPECTION REPORT KWIKSTOP 3, 1104 WASHINGTON;)r,BLDG 1104 WASHINGTON ST-STEA, WATERLOO IA =' IP 44%0 - --- , DETAILS Inspection Date:06/01/2021 I Inspection Type:Annual Inspection(1Yr) f Inspecti Number: 1035 I Shift: N/A I Station: N/A Unit: N/ I Lead lnspctor:JEFF SIEBEL ; Other Inspectors: N/A Fe .$80.00 STATUS CODE DESCRIPTION FAIL 605.6-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers conditions shall be provided for all switch and electrical outlet boxes. Inspector:JEFF SIEBEL-Comments:replace missing breakers in electrical panel or install listed blanks FAIL 605.7-Appliances Electrical appliances and fixtures shall be tested and listed in published reports of inspected electrical equipment by an approved agency and installed and maintained in accordance with all instructions included as part of such listing. Inspector:JEFF SIEBEL-Comments:toaster and coffee pot must plug directly into wall outlet,not power strip. FAIL 906.2-General requirements Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1. Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual inspection for fire extinguishers GENERAL NOTES JEFF SIEBEL-06/02/2021 @ 07:36 annual inspection$80 Printed on 06/02/2021 @ 07:37 Page 1 of 2 REINSPECTION DATE 06/22/2021 CONTACT SIGNATURE Mohammad ILYAS (� Signed on:06/02/2021 @ 07:32 r'`���� y 4ij 6vit1/61 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:06/02/2021 @ 07:32 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 06/02/2021 @ 07:37 Page 2 of 2 ATERLOO FIRE RESCUE D2 ' p'C8RL0 INSPECTION REPORT 41:t';'` 'GYRO HUT, 1104 WASHINGTO ST,BLDG 1104 WASHINGTON ST-STE B, WATERLOO IA 50702 attiO D AILS Inspection ate:06/01/2021/l Inspection Type:Annual Inspection(1Yr) ,-friSp-ec on Number:1036 I Shift: N/A I Station: N/A Unit: N/A ? ad Inspect :JEFF SIEBEL 1 Other Inspectors: N/A I Fe :$50.00 STATUS CODE DESCRIPTION FAIL 904.12.6.2-Extinguishing Automatic fire-extinguishing systems shall be serviced at least every six months and system service after activation of the system. Inspection shall be by qualified individuals,and a certificate of inspection shall be forwarded to the fire code official upon completion. Inspector:JEFF SIEBEL-Comments:provide current semi-annual kitchen hood fire suppression system inspection with all discrepancies corrected.Contactor must upload online to the compliance engine.currently 94 days past due GENERAL NOTES JEFF SIEBEL-06/02/2021 @ 09:40 Hood fire suppression 94 days overdue. Hood cleaning due on 6/9/21. Both are every 6 months. JEFF SIEBEL-06/02/2021 @ 09:39 annual inspection $50 REINSPECTION DATE 06/22/2021 CONTACT SIGNATURE Manager Signed on:06/02/2021 @ 09:37 C" L. t3. INSPECTOR SIGNATURE JEFF SIEBEL Signed on:06/02/2021 @ 09:37 Printed on 06/02/2021 @ 09:42 Page 1 of 2