COMMERCIAL INSPECTION-504 SYCAMORE-4-26-21 FOR BILLING INQUIRY: (319)291-4323
L Description I Total Price j
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# I BILLING DATE I DUE DATE INVOICE# CHARGES
23251 06/15/2021 07/30/2021 I 2021-00000289 $80.00
Less Prepayment $0.00
Total Due—} $80.00
City of Waterloo
WATERLOO FIRE RESCUE 6-1
41: rip
INSPECTION REPORT
ARIZ 504 SYCAMORE ST,BLDG 504 SYCAMORE ST, WATERLOO IA 50703
Inspection Da'04/26/2021 1 Inspection Type:Annual Inspection(1Yr ',Inspection
� p� on Number:4198 I Shift: N/A ! Station: N/A I
Unit: N/A 1 Lead Inspector:JEFF SIEBEL f Other Inspectors: N/A I Fee':$80.00'
STATUS CODE DESCRIPTION
FAIL 509.1 -Identification Fire protection equipment shall be identified in an approved manner. Rooms
containing controls for air-conditioning systems,sprinkler risers and valves,or other
fire detection,suppression or control elements shall be identified for the use of the
fire department.Approved signs required to identify fire protection equipment and
equipment location shall be constructed of durable materials,permanently installed
and readily visible.
Inspector:JEFF SIEBEL-Comments:Install permanent signage"Fire Sprinkler Riser
Room"on door to fire sprinkler
FAIL 605.4-Multiplug adapters Multiplug adapters,such as cube adapters,unfused plug strips or any other device
not complying with NFPA 70 shall be prohibited.
Inspector:JEFF SIEBEL-Comments:remove multi-plug adapter. Must use power
supply with manual reset for light duty items.
FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10. Exceptions:1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall
be allowed to be once every 3 years for dry-chemical or halogenated agent portable
fire extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1. Electronic
monitoring shall confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic
monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be
installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic
monitoring devices and supervisory circuits shall be tested every 3 years when
extinguisher maintenance is performed.2.5.A written log of required hydrostatic
test dates for extinguishers shall be maintained by the owner to verify that
hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3,
portable fire extinguishers shall be permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments:provide annual fire extinguisher service
GENERAL NOTES
JEFF SIEBEL-04/27/2021 @ 07:14 annual inspection$80
Printed on 04/27/2021 @ 07:35
Page 1 of 2
REINSPECTION DATE
05/17/2021
CONTACT SIGNATURE
Helen Redding icI
Signed on:04/27/2021 @ 07:33
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:04/27/2021 @ 07:33