Loading...
HomeMy WebLinkAbout504 SYCAMORE INVOICE DATE DUE DATE INVOICE# TOTAL DUE Aluil irk 06/15/2021 07/30/2021 2021-00000289 $80.00 /too Customer#: 23251 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ARPZ 715 Mulberry St 504 SYCAMORE ST WATERLOO, IA 50703 WATERLOO,IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-504 SYCAMORE-4-26-21 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price j INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# I BILLING DATE I DUE DATE INVOICE# CHARGES 23251 06/15/2021 07/30/2021 I 2021-00000289 $80.00 Less Prepayment $0.00 Total Due—} $80.00 City of Waterloo WATERLOO FIRE RESCUE 6-1 41: rip INSPECTION REPORT ARIZ 504 SYCAMORE ST,BLDG 504 SYCAMORE ST, WATERLOO IA 50703 Inspection Da'04/26/2021 1 Inspection Type:Annual Inspection(1Yr ',Inspection � p� on Number:4198 I Shift: N/A ! Station: N/A I Unit: N/A 1 Lead Inspector:JEFF SIEBEL f Other Inspectors: N/A I Fee':$80.00' STATUS CODE DESCRIPTION FAIL 509.1 -Identification Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems,sprinkler risers and valves,or other fire detection,suppression or control elements shall be identified for the use of the fire department.Approved signs required to identify fire protection equipment and equipment location shall be constructed of durable materials,permanently installed and readily visible. Inspector:JEFF SIEBEL-Comments:Install permanent signage"Fire Sprinkler Riser Room"on door to fire sprinkler FAIL 605.4-Multiplug adapters Multiplug adapters,such as cube adapters,unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. Inspector:JEFF SIEBEL-Comments:remove multi-plug adapter. Must use power supply with manual reset for light duty items. FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1. Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual fire extinguisher service GENERAL NOTES JEFF SIEBEL-04/27/2021 @ 07:14 annual inspection$80 Printed on 04/27/2021 @ 07:35 Page 1 of 2 REINSPECTION DATE 05/17/2021 CONTACT SIGNATURE Helen Redding icI Signed on:04/27/2021 @ 07:33 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:04/27/2021 @ 07:33 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 04/27/2021 @ 07:35 Page 2 of 2