Loading...
HomeMy WebLinkAbout1740 FALLS AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE ! ilk t� 06/15/2021 07/3 0/2021 1 SeiMirt�t 2021-00000313 $80.00 o er/aa Customer#: 3321 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable STEAMBOAT GARDENS 715 Mulberry St 1740 FALLS AV WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1740 FALLS AVE-4-20-21 I FOR BILLING INQUIRY: (319)291-4323 L Description I � Total Price.1 INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 3321 06/15/2021 07/30/2021 2021-00000313 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo �PTER(pp RE RESCUE A TERLOO ..,,e.�...._—__. //INSPECTION REPORT STEAMBOAT GARDENS,1740 FALLS AV ,BLDG 1740 FALLS AVE,WATERLOO/A 50701 4420 'DETAILS .. •Annual Inspection(1v,) Inspection Number:4475 Shift: N/A I Station: N/A Inspection Type: p ' Inspection Date:04/20/202� p Unit: N/A I Le JEFF SIEBEL Other Inspectors: N/A I Fee:$80.00 STATUS jCODE DESCRIPTION Compressed gas containers,cylinders and tanks shall be secured to pree gas falling compressedFAIL o03.5.3- ecuring por seismic gas containers, caused by contact,vibration shallbe bygvity.one of thelng of following methods: 1.Securing containers,cylinders and tanks cylinders andone containers,cylinders and tanks to a fixed obja�withart otherr more mobilerdevice designed estraints.2. Securing containers,cylinders and tanks on for the movement of compressed gas containers,cylinders c orr tanks.ng 3 servicig ng gof compressed gas containers,cylinders and tanks at facilities or in sellers'warehouses not accessible to the et public. ic dislodged,Nesting dol bet e allowed provided the nested containers,cylinders obstruct the required means of egress.4.Securing of compressed a gas r stainers, cylinders and tanks to or within a rack,framework, mbly designed for such use. Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Inspector:JEFF SIEBEL-Comments:secure all compressed gas cylinders in basement with chain. FAIL 604.2.12 eg ress of e ress Emergency power shall be provided for means of egress illumination in accordance illumination with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:repair egress light by ice machine hanging by wires. -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including, FAIL 703.1partitions,smoke barriers, but not limited to,walls,firestops,shaft enclosures, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint smannuashall lly and properly repaired, elements shall be visually inspected by the owner restored or replaced where damaged,altered,breached or penetrated.Records of inspections and repairs shall be maintained.Wherne°unless tdhe concea ed elements space is not be required to be visually inspected by the ow accessible by the removal or movement of a phe Sin forthe passageel,accss door, 'ng tile of pipes,or similar movable entry to the space.Openings made electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-ratedt'ones shal bemeeting t pe firerotected by p otection self-or automatic-closing doors of approved constru requirements for the assembly. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile in kitchen. Printed on 04/21/2021 @ 10:05 Page 1 of 3 • STATUS CODE DESCRIPTION FAIL 904.12.6.2-Extinguishing Automatic fire-extinguishing systems shall be serviced at least every six months and system service after activation of the system. Inspection shall be by qualified individuals,and a certificate of inspection shall be forwarded to the fire code official upon completion. Inspector:JEFF SIEBEL-Comments:provide semi-annual kitchen hood fire suppression inspection with all discrepancies corrected.Contractor must upload online to the compliance engine. FAIL 904.12.6.3-Fusible link and Fusible links and automatic sprinkler heads shall be replaced at least annually,and sprinkler head replacement other protection devices shall be serviced or replaced in accordance with the manufacturer's instructions. Exception: Frangible bulbs are not required to be replaced annually. Inspector:JEFF SIEBEL-Comments:provide semi-annual kitchen hood fire suppression inspection with all discrepancies corrected.Contractor must upload online to the compliance engine. FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1. Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers. GENERAL NOTES JEFF SIEBEL-04/21/2021 @ 10:00 annual inspection$80 JEFF SIEBEL-04/21/2021 @ 10:00 kitchen hood cleaning 12/6/21 AKA REINSPECTION DATE 05/11/2021 Printed on 04/21/2021 @ 10:05 Page 2 of 3 CONTACT SIGNATURE Joel Hundley Signed on:04/21/2021 @ 10:01 (`- ' jo INSPECTOR SIGNATURE JEFF SIEBEL Signed on:04/21/2021 @ 10:01 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 04/21/2021 @ 10:05 Page 3 of 3