COMMERCIAL INSPECTION- 1740 FALLS AVE-4-20-21 I FOR BILLING INQUIRY: (319)291-4323
L Description I
� Total Price.1
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
3321 06/15/2021 07/30/2021 2021-00000313 $80.00
Less Prepayment $0.00
Total Due $80.00
City of Waterloo
�PTER(pp
RE RESCUE
A TERLOO ..,,e.�...._—__.
//INSPECTION REPORT
STEAMBOAT GARDENS,1740 FALLS AV ,BLDG 1740 FALLS AVE,WATERLOO/A 50701
4420
'DETAILS ..
•Annual Inspection(1v,) Inspection Number:4475 Shift: N/A I Station: N/A
Inspection Type: p '
Inspection Date:04/20/202� p
Unit: N/A I Le JEFF SIEBEL Other Inspectors: N/A I Fee:$80.00
STATUS jCODE
DESCRIPTION
Compressed gas containers,cylinders and tanks shall be secured to pree gas falling
compressedFAIL
o03.5.3- ecuring por seismic
gas containers, caused by contact,vibration shallbe bygvity.one of thelng of following methods: 1.Securing
containers,cylinders and tanks
cylinders andone
containers,cylinders and tanks to a fixed obja�withart otherr more mobilerdevice designed
estraints.2.
Securing containers,cylinders and tanks on
for the movement of compressed gas containers,cylinders c orr tanks.ng 3 servicig ng
gof
compressed gas containers,cylinders and tanks at
facilities or in sellers'warehouses not accessible to the
et public.
ic dislodged,Nesting
dol bet
e
allowed provided the nested containers,cylinders
obstruct the required means of egress.4.Securing of compressed
a gas
r stainers,
cylinders and tanks to or within a rack,framework,
mbly
designed for such use. Exception:Compressed gas containers,cylinders and tanks in
the process of examination,filling,transport or servicing.
Inspector:JEFF SIEBEL-Comments:secure all compressed gas cylinders in basement
with chain.
FAIL 604.2.12 eg
ress of e ress Emergency power shall be provided for means of egress illumination in accordance
illumination with Sections 1008.3 and 1104.5.1.
Inspector:JEFF SIEBEL-Comments:repair egress light by ice machine hanging by
wires.
-Maintenance The required fire-resistance rating of fire-resistance-rated construction,including,
FAIL 703.1partitions,smoke barriers,
but not limited to,walls,firestops,shaft enclosures,
floors,fire-resistive coatings and sprayed fire-resistant materials applied to
structural members and fire-resistant joint smannuashall
lly and properly repaired,
elements shall be visually inspected by the owner
restored or replaced where damaged,altered,breached or penetrated.Records of
inspections and repairs shall be maintained.Wherne°unless tdhe concea ed elements
space is
not be required to be visually inspected by the ow
accessible by the removal or movement of a phe Sin forthe passageel,accss door, 'ng tile of pipes,or similar
movable entry to the space.Openings made
electrical conduit,wires,ducts,air transfer openings and holes made for any reason
shall be protected with approved methods capable of resisting the passage of smoke
and fire.Openings through fire-resistance-ratedt'ones shal bemeeting t pe firerotected by
p otection
self-or automatic-closing doors of approved
constru
requirements for the assembly.
Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile in kitchen.
Printed on 04/21/2021 @ 10:05
Page 1 of 3
•
STATUS CODE DESCRIPTION
FAIL 904.12.6.2-Extinguishing Automatic fire-extinguishing systems shall be serviced at least every six months and
system service after activation of the system. Inspection shall be by qualified individuals,and a
certificate of inspection shall be forwarded to the fire code official upon completion.
Inspector:JEFF SIEBEL-Comments:provide semi-annual kitchen hood fire
suppression inspection with all discrepancies corrected.Contractor must upload
online to the compliance engine.
FAIL 904.12.6.3-Fusible link and Fusible links and automatic sprinkler heads shall be replaced at least annually,and
sprinkler head replacement other protection devices shall be serviced or replaced in accordance with the
manufacturer's instructions. Exception: Frangible bulbs are not required to be
replaced annually.
Inspector:JEFF SIEBEL-Comments:provide semi-annual kitchen hood fire
suppression inspection with all discrepancies corrected.Contractor must upload
online to the compliance engine.
FAIL 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall
be allowed to be once every 3 years for dry-chemical or halogenated agent portable
fire extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1. Electronic
monitoring shall confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic
monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be
installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic
monitoring devices and supervisory circuits shall be tested every 3 years when
extinguisher maintenance is performed.2.5.A written log of required hydrostatic
test dates for extinguishers shall be maintained by the owner to verify that
hydrostatic tests are conducted at the frequency required by NFPA 10.3. In Group 1-3,
portable fire extinguishers shall be permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers.
GENERAL NOTES
JEFF SIEBEL-04/21/2021 @ 10:00 annual inspection$80
JEFF SIEBEL-04/21/2021 @ 10:00 kitchen hood cleaning 12/6/21 AKA
REINSPECTION DATE
05/11/2021
Printed on 04/21/2021 @ 10:05
Page 2 of 3
CONTACT SIGNATURE
Joel Hundley
Signed on:04/21/2021 @ 10:01
(`- '
jo
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:04/21/2021 @ 10:01
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed on 04/21/2021 @ 10:05
Page 3 of 3