COMMERCIAL INSPECTION-2833 CROSSROADS BLVD-4-12-21 FOR BILLING INQUIRY: (319)291-4323
L Description I Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE IlWOICE# CHARGES
21000 06/15/2021 07/30/2021 2021-00000304 $80.00
Less Prepayment $0.00
Total Due--> $80.00
City of Waterloo
WATERLOO FIRE-RESCUE C psERLo
�1 p
/NSP�''E'TI�?N REPORT ��,,/ /I-
11
NOODLES&CO,2833 CROSSROADS BLVD,BLDG 2388 CROSSROADS BLVD,WATERLOO IA
. 44'410
DE ra
Inspection Date:04/12/2021,f Inspection Type:Annual Inspection(1 r) ; Inspection Number: 1313 I Shift: N/A Station: N/A I
Unit: N/A ; Lead Inspe r:JEFF SIEBEL I Other Inspectors: N/A I Fee:$80.00
STATUS CODE DESCRIPTION
FAIL 1004.3-Posting of occupant Every room or space that is an assembly occupancy shall have the occupant load of
load the room or space posted in a conspicuous place,near the main exit or exit access
doorway from the room or space. Posted signs shall be of an approved legible
permanent design and shall be maintained by the owner or the owner's authorized
agent.
Inspector:JEFF SIEBEL-Comments:post occupant load sign provided by fire
department.
FAIL 604.2.12-Means of egress Emergency power shall be provided for means of egress illumination in accordance
illumination with Sections 1008.3 and 1104.5.1.
Inspector:JEFF SIEBEL-Comments:repair egress lights:A.above W windows in dining
area.B.egress lights in women's restroom.
FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments:repair egress/exit lights:A.above main door,
hanging by wires.B.above"order"door.(E door).C.NW exit from dining by RR.D.
above kitchen exit.
FAIL 609.3.3.1 -Inspection Hoods,grease-removal devices,fans,ducts and other appurtenances shall be
inspected at intervals specified in Table or as approved by the fire code official.
Inspections shall be completed by qualified individuals.
Inspector:JEFF SIEBEL-Comments:provide current semi-annual kitchen hood
exhaust system cleaning with all discrepancies corrected.contractor must upload
online to the compliance engine.
Printed on 04/13/2021 @ 15:46
Page 1 of 3
r • c
STATUS CODE DESCRIPTION
FAI_L 906.2-General requirements Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall
be allowed to be once every 3 years for dry-chemical or halogenated agent portable
fire extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1. Electronic
monitoring shall confirm that extinguishers are properly positioned,properly
charged and unobstructed.2.2. Loss of power or circuit continuity to the electronic
monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be
installed inside of a building or cabinet in a noncorrosive environment.2.4. Electronic
monitoring devices and supervisory circuits shall be tested every 3 years when
extinguisher maintenance is performed.2.5.A written log of required hydrostatic
test dates for extinguishers shall be maintained by the owner to verify that
hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,
portable fire extinguishers shall be permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguishers.
GENERAL NOTES
JEFF SIEBEL-04/13/2021 @ 15:45 annual inspection$80
JEFF SIEBEL-04/13/2021 @ 15:45 kitchen fire suppression Synergy 1/12/21
REINSPECTION DATE
05/04/2021
CONTACT SIGNATURE
Nikki Smelcer
Signed on:04/13/2021 @ 15:27 VQ .(1-7
14.E st
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:04/13/2021 @ 15:27
Printed on 04/13/2021 @ 15:46