COMMERCIAL INSPECTION- 728 COMMERCIAL ST-5-11-21 FOR BILLING INQUIRY: (319)291-4323
L Description Total Price
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES.
6422 06/15/2021 07/30/2021 2021-00000288 $80.00
Less Prepayment $0.00
Total Due--} $80.00
City of Waterloo
Cp'C�RCp
WATERLOO FIRE RESCUE
INSPECTION REPORT 4 ;447
AMERICAN LEGION POST 138,728 COMMERCIAL ST,BLDG 728 COMMERCIAL ST,WATERLOO `
IA 50702
DETAILS
Inspection ate:05/11/2021 1 Inspection Type:Annual Inspection( Insp ion Number:4740 1 Shift: N/A Station: N/A
Unit: N/A I ead Inspector JEFF SIEBEL 1 Other Inspectors: N/A Fee:$80.00
STATUS CODE DESCRIPTION
FAIL 1010.1.9.4-Bolt locks Manually operated flush bolts or surface bolts are not permitted. Exceptions:1.On
doors not required for egress in individual dwelling units or sleeping units.2.Where
a pair of doors serves a storage or equipment room,manually operated edge-or
surface-mounted bolts are permitted on the inactive leaf.3.Where a pair of doors
- V serves an occupant load of less than 50 persons in a Group B, F or S occupancy,
manually operated edge-or surface-mounted bolts are permitted on the inactive
"' ix 4 leaf.The inactive leaf shall not contain doorknobs,panic bars or similar operating
NIA hardware.4.Where a pair of doors serves a Group B,F or S occupancy,manually
a&a, 41
operated edge-or surface-mounted bolts are permitted on the inactive leaf provided
such inactive leaf is not needed to meet egress capacity requirements and the
building is equipped throughout with an automatic sprinkler system in accordance
with Section 903.3.1.1.The inactive leaf shall not contain doorknobs,panic bars or
similar operating hardware.5.Where a pair of doors serves patient care rooms in
Group 1-2 occupancies,self-latching edge-or surface-mounted bolts are permitted on
the inactive leaf provided that the inactive leaf is not needed to meet egress capacity
requirements and the inactive leaf shall not contain doorknobs, panic bars or similar
operating hardware.
Inspector:JEFF SIEBEL-Comments:remove slide bolt lock from the back alley door.
Strictly prohibited.
FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments:repair exit/egress light above main front door.
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated.Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector:JEFF SIEBEL-Comments:replace missing breaker or install listed blank in
Panel A.
Printed on 05/12/2021 @ 1019
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including,
but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers,
floors,fire-resistive coatings and sprayed fire-resistant materials applied to
structural members and fire-resistant joint systems,shall be maintained.Such
elements shall be visually inspected by the owner breachedlly and or penetoatedyRepordsdof
restored or replaced where damaged,altered,
inspections and repairs shall be maintained.Where concealed,such elements shall
not be required to be visually inspected by the owner unless the concealed space is
accessible by the removal or movement of thereinforthe passage of pipe panel,
)ng tile or similar
movable entry to the space.Openings made
electrical conduit,wires,ducts,air transfer openings and holes made for any reason
shall be protected with approved methods capable of resisting the passage of smoke
and fire.Openings through fire-resistan assemblies
meeting t protected
p otection
self-or automatic-closing doors of approved construe on
requirements for the assembly.
Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile in kitchen.
GENERAL NOTES
JEFF SIEBEL-05/12/2021 @ 09:55 annual inspection$80
REINSPECTION DATE
06/01/2021
CONTACT SIGNATURE
Sarah Hoffman ce(/ 1.6�
Signed on:05/12/2021 @ 10:16
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:05/12/2021 @ 10:16
Printed on 05/12/2021 @ 10:19