Loading...
HomeMy WebLinkAbout728 COMMERCIAL ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE ilk Air di �� 06/15/2021 07/30/2021 2021-00000288 $80.00 ajane lypit Customer#: 6422 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable AMERICAN LEGION 715 Mulberry St 728 COMMERCIAL ST WATERLOO, IA 50703 WATERLOO,IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 728 COMMERCIAL ST-5-11-21 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES. 6422 06/15/2021 07/30/2021 2021-00000288 $80.00 Less Prepayment $0.00 Total Due--} $80.00 City of Waterloo Cp'C�RCp WATERLOO FIRE RESCUE INSPECTION REPORT 4 ;447 AMERICAN LEGION POST 138,728 COMMERCIAL ST,BLDG 728 COMMERCIAL ST,WATERLOO ` IA 50702 DETAILS Inspection ate:05/11/2021 1 Inspection Type:Annual Inspection( Insp ion Number:4740 1 Shift: N/A Station: N/A Unit: N/A I ead Inspector JEFF SIEBEL 1 Other Inspectors: N/A Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1010.1.9.4-Bolt locks Manually operated flush bolts or surface bolts are not permitted. Exceptions:1.On doors not required for egress in individual dwelling units or sleeping units.2.Where a pair of doors serves a storage or equipment room,manually operated edge-or surface-mounted bolts are permitted on the inactive leaf.3.Where a pair of doors - V serves an occupant load of less than 50 persons in a Group B, F or S occupancy, manually operated edge-or surface-mounted bolts are permitted on the inactive "' ix 4 leaf.The inactive leaf shall not contain doorknobs,panic bars or similar operating NIA hardware.4.Where a pair of doors serves a Group B,F or S occupancy,manually a&a, 41 operated edge-or surface-mounted bolts are permitted on the inactive leaf provided such inactive leaf is not needed to meet egress capacity requirements and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1.The inactive leaf shall not contain doorknobs,panic bars or similar operating hardware.5.Where a pair of doors serves patient care rooms in Group 1-2 occupancies,self-latching edge-or surface-mounted bolts are permitted on the inactive leaf provided that the inactive leaf is not needed to meet egress capacity requirements and the inactive leaf shall not contain doorknobs, panic bars or similar operating hardware. Inspector:JEFF SIEBEL-Comments:remove slide bolt lock from the back alley door. Strictly prohibited. FAIL 604.2.5-Exit signs Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair exit/egress light above main front door. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated.Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:JEFF SIEBEL-Comments:replace missing breaker or install listed blank in Panel A. Printed on 05/12/2021 @ 1019 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including, but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner breachedlly and or penetoatedyRepordsdof restored or replaced where damaged,altered, inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of thereinforthe passage of pipe panel, )ng tile or similar movable entry to the space.Openings made electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistan assemblies meeting t protected p otection self-or automatic-closing doors of approved construe on requirements for the assembly. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile in kitchen. GENERAL NOTES JEFF SIEBEL-05/12/2021 @ 09:55 annual inspection$80 REINSPECTION DATE 06/01/2021 CONTACT SIGNATURE Sarah Hoffman ce(/ 1.6� Signed on:05/12/2021 @ 10:16 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:05/12/2021 @ 10:16 Printed on 05/12/2021 @ 10:19 Page 2 of 3