HomeMy WebLinkAbout1411 W 6TH ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE
/IPA, 01/13/2022 02/15/2022 2022-00000107 $50.00
igitzlime
111)
4terlo0
Customer#: 12490 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
METRO INVESTMENTS 715 Mulberry St
2117 FALLS AVE WATERLOO, IA 50703
WATERLOO,IA 50701
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL INSPECTION- 1411 W 6TH ST- 1-12-22 FOR BILLING INQUIRY: (319)291-4323
[Description Total Price]
REINSPECTION FEE $50.00
g5
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
12490 01/13/2022 02/15/2022 2022-00000107 $50.00
Less Prepayment $0.00
Total Due--> $50.00
City of Waterloo
t., c.c. a,,
e:
RESCUE ?4,6m:r
Po• 9n6
WATERLOOFIRE �� '�
INSPECTION REPORT ‘A C-k a`
141iW8"fHS'T.WATER �
DETAILS
Rental Inspection � Inspection Number:711 I Shift: N/A I Station: N/A I
P .
Inspection Date:01/12/2022 I Inspection ectian Type:Re
Unit: N/A I Lead Inspector:BARRY STRATTON l Other Inspectors: N/A Fee:$50.00 id.�te)/t,
'.1'/��J'
STATUS CODE
DESCRIPTION
emergency escape and rescue openings shall be maintained in accordance
1031.7-Emergency escape Required g ry and the following:Required
FAIL with the code in effect at the time of construction,
and rescue openings
emergency escape and rescue openings shall be operational or similarhdevices are e inside of the
room without the use of keys or tools.Bars,grilles,grates
allowed to be placed over emergency escape and rescue
openings n provide
ov d ad the time
the
minimum net clear opening size complies with the code that was
iof construction and such devices shall be releasable or removable
able from for n ide
without the use of a key,tool or force greater than that whichrequired
rmal
operation of the emergency escape and rescue opening.
Inspector:BARRY STRATTON-Comments:Broken Window upstairs.
ions:
FAIL 906.1 -Where required d Portable fire extinguishers shall be installed in all of the following ielo atException:1.Inn new
and existing Group A,B,E,F, H,I,M,R-1,R-2,R-4 andS o p
Group R-2 occupancies,portable fire extinguishers shall bere quuir only in oca ati ns
specified in Items 2 through 6 where each dwelling unit is
p
fire extinguisher having a minimum rating of 1-A:10-B: Within
30 combufeet stibleu91b44 mm)
of commercial cooking equipment.3. In areas where flammable
liquids are stored,used or dispensed.4.On each floor ance with Section structures der 3315.1.5.
construction,except Group R-3 occupancies,r
Where required by the sections indicated in Table 906.1.
6. andp genea cardtor areas,
including but not limited to laboratories,computer
where required by the fire code official.
Inspector:BARRY STRATTON-Comments:
UL
7
FAIL 907.2.11
-and Listed single-and multiple-station smoke alarms complying wit 1 6 and1 shall
7e
multiple-station
e-station smoke installed in accordance with Sections 907.2.11.1 through
2.
alarms
Inspector:BARRY STRATTON-Comments:Smoke detectors needed in each bedroom.
outside bedrooms,and in basement.
Was the presence of unsafe equipment noted duringe the
inspection?
electrical Equipment and
FAIL may
R2-Unsafe Equipment
include boilers,heating equipment,elevator,moving
flammable liquid containers.(IPMC 108.1.2)
Inspector:BARRY STRATTON-Comments:Drain pipe to sanitary stack not installed to
code.Shower needs repaired for leaks.
Painted on 4 112i2022 L.11=43
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,and pest
infestations.(IPMC 302)
Inspector:BARRY STRATTON-Comments:Roof/gutters/drainage in to basement.
FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector:BARRY STRATTON-Comments:Foundation is leaking
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments:Several leaks in basement.Leaks from
foundation. Plumbing leaks and water valve for outside faucet is leaking into
basement.Shower leaking into basement through floor.Water leaking onto
bathroom floor from shower.Need handrails to upstairs. Broken windows upstairs
need fixed.Sewer gas smell in basement.Drain pipe in basement not secured to
code.Wire hanger rapped around electric conduit not allowed.Drain pipe appears to
go nowhere. Floor in bathroom need repaired from water damage.Ceiling in
basement under bathroom damaged from water. Bedroom wall paneling pulling
away from wall needs repaired.Today's inspection the kitchen sink is not backed up.
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector:BARRY STRATTON-Comments:Potential for mold to form with all water
leaks.Mold on upstairs walls from water damage.
GENERAL NOTES
BARRY STRATTON-01/12/2022 @ 11:40 304.5 Foundation walls. Foundation walls shall be maintained plumb and free from
open cracks and breaks and shall be kept in such condition so as to prevent the entry
of rodents and other pests.
BARRY STRATTON-01/12/2022 @ 11:41 304.7 Roofs and drainage.The roof and flashing shall be sound,tight and not have
defects that admit rain. Roof drainage shall be adequate to prevent dampness or
deterioration in the walls or interior portion of the structure. Roof drains,gutters and
downspouts shall be maintained in good repair and free from obstructions. Roof water
shall not be discharged in a manner that creates a public nuisance
Printed on 01112/2022 Cc 11:43
Page 2 of 3
GEN,I A&NOTES
BARRY STRATTON-01/12/2022 @ 11:41 504.1 General.Plumbing fixtures shall be properly installed and maintained in working
order,and shall be kept free from obstructions,leaks and defects and be capable of
performing the function for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional condition.
BARRY STRATTON-01/12/2022 @ 11:41 403.6 Mold Present In A Rental Unit.a.When mold is found to be visibly present in
small amounts,it can be cleaned in a safe and sanitary manner.b.When mold is found
in a rental unit and is determined to be a health risk,the building official may order
that a clean air report be obtained from a mold specialist approved by the building
official.
BARRY STRATTON-01/12/2022 @ 11:42 106.4: Deficiencies STILL NOT corrected. Failure to correct citation shall be issued
$500.00+95.00 court costs.Citations(s)will be issued for failure to comply with this
inspection report.
REINSPECTION DATE
02/09/2022
CONTACT SIGNATURE
Metro INvestments LLC E 4 (L ( ,��
Signed on:01/12/2022 @ 11:42 Y t
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:01/12/2022 @ 11:42
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319)231-9147
Printed an 01/12/2022,V11_43
Page 3 of 3