Loading...
HomeMy WebLinkAbout1202 W 2ND ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE 4r4r7;•, 01/13/2022 02/15/2022 2022-00000105 $50.00 4°erloo �o Customer#: 23001 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable QUALITY CONCRETE CONTRUCTION(RENTAL) 715 Mulberry St 1930 HAWTHORNE AVE#1 WATERLOO, IA 50703 WATERLOO,IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 1202 W 2ND ST- 1-11-22 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price REINSPECTION FEE $50.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23001 01/13/2022 02/15/2022 2022-00000105 $50.00 Less Prepayment $0.00 Total Due--> $50.00 City of Waterloo ..\ctc,snrAsirsL.cm.sek D\ WATERLOO FIRE RESCUE t•124 INSPECTION REPORT lc5 , 1;; ;6 1202 W 2ND ST,WATERLOO IA 50701 DETAILS Inspection Date:01/11/2022 ! Inspection Type:Rental Inspection I Inspection Number:6960 I Shift: N/A I Station: N/A I Unit: N/A I Lead Inspector:BARRY STRATTON Other Inspectors: N/A 1 Fee:$50.00 .%1414/ ,� "--As741 STATUS CODE DESCRIPTION FAIL 1018.1 -General Aisles and aisle accessways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section.Aisles or aisle accessways shall be provided from all occupied portions of the exit access that contain seats,tables,furnishings,displays and similar fixtures or equipment.The minimum width or required capacity of aisles shall be unobstructed.Exception: Encroachments complying with Section 1005.7. Inspector:BARRY STRATTON-Comments:Egress path obstructions FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:BARRY STRATTON-Comments:Doors and jambs broken. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated.Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments:Missing globes, Electric panel blocked and appliances in basement. Printed on 01/11/2022 11:59 Page 1 of 6 STATUS CODE DESCRIPTION FAIL 703.1 -Maintenance The required fire-resistance rating of fire-resistance-rated construction,including, but not limited to,walls,firestops,shaft enclosures,partitions,smoke barriers, floors,fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems,shall be maintained.Such elements shall be visually inspected by the owner annually and properly repaired, restored or replaced where damaged,altered,breached or penetrated.Records of inspections and repairs shall be maintained.Where concealed,such elements shall not be required to be visually inspected by the owner unless the concealed space is accessible by the removal or movement of a panel,access door,ceiling tile or similar movable entry to the space.Openings made therein for the passage of pipes, electrical conduit,wires,ducts,air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire.Openings through fire-resistance-rated assemblies shall be protected by self-or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Inspector:BARRY STRATTON-Comments:Ceiling in living room still not fixed.Water is still leaking in living room.Walls damaged from water and floor has been removed where mold and water damage occurred. FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations:1.In new and existing Group A,B,E,F, H,I, M,R-1,R-2, R-4 and S occupancies.Exception:In Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3.In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3315.1.5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector:BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector:BARRY STRATTON-Comments:Smoke detectors need installed to meet code requirements. FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector:BARRY STRATTON-Comments:CO detectors needed FAIL R1 -Unsafe Structures Is the structure found to be dangerous to the life,health,property or safety of either the public or occupants of the structure?(IPMC 108.1.1) Printed on 01/11/2022 11:59 Page 2 of 6 STATUS CODE DESCRIPTION Inspector:BARRY STRATTON-Comments: FAIL R3-Unfit for Human is the structure found to be fit for human occupancy according to the code?(IPMC Occupancy 108.1.3) Inspector:BARRY STRATTON-Comments:Ceiling in living room and fallen,roof leaking,no maintenance to apartments,mold.Holes in walls from water damage. FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector:BARRY STRATTON-Comments:Debris FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Inspector:BARRY STRATTON-Comments:Deck stairs and landing FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector:BARRY STRATTON-Comments:Entry door needs replaced.jamb and door are broken.Broken windows need replaced. Egress path is blocked in kitchen because refrigerator is blocking path.Ceiling in living room has collapsed.Ceiling tiles are damaged by water leak.bath sink is not secured to wall in bathroom.Sewer leak in basement needs repaired by licensed professional.Screen door does not have any door hardware.Back door to 1202 did not function because tenant advised it is broken.Security hardware to keep door secured in jamb is broken and jamb not capable to keep door secured and weather tight. FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector:BARRY STRATTON-Comments:Mold,egress,and currently stove being used to heat apartment because furnace does not work. FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) inspector:BARRY STRATTON-Comments:Furnace can not maintain 68 degrees with all the broken windows in building. Maintenance to furnace needed and new windows need installed in building. GENERAL NOTES Printed on 01/11/2022; 11.39 Page 3 of 6 BARRY STRATTON-01/11/2022 @ 11:56 108.1.3 Structure unfit for human occupancy.A structure is unfit for human occupancy whenever the code official finds that such structure is unsafe,unlawful or,because of the degree to which the structure is in disrepair or lacks maintenance,is insanitary, vermin or rat infested,contains filth and contamination,or lacks ventilation, illumination,sanitary or heating facilities or other essential equipment required by this code,or because the location of the structure constitutes a hazard to the occupants of the structure or to the public. BARRY STRATTON-01/11/2022 @ 11:56 108.1.2 Unsafe equipment.Unsafe equipment includes any boiler,heating equipment, elevator,moving stairway,electrical wiring or device,flammable liquid containers or other equipment on the premises or within the structure which is in such disrepair or condition that such equipment is a hazard to life,health,property or safety of the public or occupants of the premises or structure. Furnace not working and stove being used for heat source. BARRY STRATTON-01/11/2022 @ 11:57 108.1.1 Unsafe structures.An unsafe structure is one that is found to be dangerous to the life,health,property or safety of the public or the occupants of the structure by not providing minimum safeguards to protect or warn occupants in the event of fire, or because such structure contains unsafe equipment or is so damaged,decayed, dilapidated,structurally unsafe or of such faulty construction or unstable foundation, that partial or complete collapse is possible. Building is uninhabitable in correct condition. BARRY STRATTON-01/11/2022 @ 11:57 302.1 Sanitation.Exterior property and premises shall be maintained in a clean,safe and sanitary condition.The occupant shall keep that part of the exterior property that such occupant occupies or controls in a clean and sanitary condition. BARRY STRATTON-01/11/2022 @ 11:57 304.15 Doors. Exterior doors,door assemblies,operator systems if provided,and hardware shall be maintained in good condition. Locks at all entrances to dwelling units and sleeping units shall tightly secure the door.Locks on means of egress doors shall be in accordance with Section 702.3.All interior doors/jambs and all exterior doors/jambs. BARRY STRATTON-01/11/2022 @ 11:57 304.10 Stairways,decks,porches and balconies.Every exterior stairway,deck,porch and balcony,and all appurtenances attached thereto,shall be maintained structurally sound,in good repair,with proper anchorage and capable of supporting the imposed loads BARRY STRATTON-01/11/2022 @ 11:57 304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition. BARRY STRATTON-01/11/2022 @ 11:57 304.13 Window,skylight and door frames. Every window,skylight,door and frame shall be kept in sound condition,good repair and weather tight. Printed on 01/11/2022 11:59 Page 4 of 6 • GENERAL NOTES BARRY STRATTON-01/11/2022 @ 11:58 305.2 Structural members.Structural members shall be maintained structurally sound, and be capable of supporting the imposed loads. BARRY STRATTON-01/11/2022 @ 11:58 305.3 Interior surfaces.Interior surfaces,including windows and doors,shall be maintained in good,clean and sanitary condition.Peeling,chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. BARRY STRATTON-01/11/2022 @ 11:58 308.1 Accumulation of rubbish or garbage. Exterior property and premises,and the interior of every structure,shall be free from any accumulation of rubbish or garbage. (Basement) BARRY STRATTON-01/11/2022 @ 11:58 504.1 General. Plumbing fixtures shall be properly installed and maintained in working order,and shall be kept free from obstructions,leaks and defects and be capable of performing the function for which such plumbing fixtures are designed.Plumbing fixtures shall be maintained in a safe,sanitary and functional condition. BARRY STRATTON-01/11/2022 @ 11:58 702.1 General.A safe,continuous and unobstructed path of travel shall be provided from any point in a building or structure to the public way. Means of egress shall comply with the International Fire Code. BARRY STRATTON-01/11/2022 @ 11:59 702.2 Aisles.The required width of aisles in accordance with the International Fire Code shall be unobstructed. REINSPECTION DATE 02/11/2022 CONTACT SIGNATURE Quality Concrete Construction Signed on:01/11/2022 @ 11:59 Akk_ INSPECTOR SIGNATURE BARRY STRATTON Signed on:01/11/2022 @ 11:59 Printed on 01/1112022 2 11:59 Page 5 of 6