Loading...
HomeMy WebLinkAbout606 BOSTON AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE hrifirpti,, rik 01/13/2022 02/15/2022 2022-00000098 $50.00 Customer#: 5331 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable DOROTHY HAUGEBAK 715 Mulberry St 2513 ASHLAND DR WATERLOO, IA 50703 CEDAR FALLS,IA 50613 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 606 BOSTON AVE- 12-6-21 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price REINSPECTION FEE $50.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 5331 01/13/2022 02/15/2022 2022-00000098 $50.00 Less Prepayment $0.00 Total Due— $50.00 City of Waterloo ( ' WATERLOO FIRE RESCUE «// \\„4k*-\\/ \ , 03 r _. INSPECTION REPORT �' � ll' c�V \ 606 BOSTON AVE, WATERLOO IA 50703 / �(�► , DETAILS Inspection Date: 12/06/2021 I Inspection Type: Rental Inspection l Inspection Number:6456 I Shift: N/A i Station: N/A I Unit: N/A I Lead Inspector: BARRY STRATTON f Other Inspectors: N/A } Fee:$50.00 Xf„ A , p,p410 fte STATUS CODE DESCRIPTION FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON-Comments:All outlets in kitchen are not grounded. FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment. 3. In areas where flammable or combustible liquids are stored, used or dispensed.4. On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories, computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON-Comments: Need updated fire extinguisher in unit. FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON-Comments:Smoke detector needed in hallway outside bedrooms and in basement. FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector: BARRY STRATTON-Comments:Front landing still not repaired. Fence around property not maintained in good condition. FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Pri-zed on 12105/202/i'13_D3 Page 1 of 3 ` - . ' STATUS CODE DESCRIPTION Inspector: BARRvSTRxTTOw Comments: FAIL R6 |nteriorSnocmre Has the interior of the structure and equipment inside been maintained in good repair'structurally sound,and in a sanitary condition?UPrW[305 Inspector: BARnv STnxTT0N Comments:Tub surround not changed'sink in bathroom still not attached to wall. FAIL R6.A. Interior Structure- Were any unsafe conditions noted during the interior inspeoion?(|PKUC 305.1.1) Unsafe Conditions Inspector: 8ARRYSTRATTON Comments:Flex connector still on furnace. FAIL R6.B. Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of6OF?(|PM[6OI2) Inspector:BARRYSTnATTUN Comments:Furnace gas fine needs to be hard pipe. FAIL R6.[. Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(|PrN[6O3.1) Inspector: BARRvSTRAJTDN Comments:Water supply lines not to code.Water heater installed with out permits. REINSPECTION DATE 01/O6/2U2Z CONTACT SIGNATURE Dorothy Haugebak Signed on: 12/06/2021 @ 13:07 INSPECTOR SIGNATURE BARRYSTRATTON Signed on: 12/86/2021 @ 13:07 ' p~"°uon`ou6iz0.2` ,oxm Page o of QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATT©N barry.stratton@waterloo-ia.org (319)231-9147 Printed on 12/06/2021 a 13:08 Page 3 of 3