RENTAL INSPECTION- 6220 DONEGAL CIRCLE UNIT A- 12-15-21 FOR BILLING INQUIRY: (319)291-4323
LDescription Total Price,
REINSPECTION FEE $50.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
23716 01/13/2022 02/15/2022 2022-00000099 $50.00
Less Prepayment $0.00
Total Due-* $50.00
City of Waterloo
IIC 761774- •
WATERLOO F►RE RESCUE
INSPECTION REPORT • �� %9+
BLDG 6220 DONEGAL CIR,6025 DONEGAL CIR, WATERLOO IA 507 �\ :,-,of
DETAILS .r } XV
Inspection Date: 12/15/2021 j Inspection Type: Rental Inspectiopl Inspection Number:7126 I Shift: N/A ! Station: N/A
Unit: N/A I Lead Inspector:BARRY STRATTON j Other Inspector s: N/A I Fee:$50.00 „t'/v j /S, /f' � eja.
rnail'
y.
STATUS CODE DESCRIPTION
t
FAIL 1010.1.9- Door operations Except as specifically permitted by this section, egress doors shall be readily
openable from the egress side without the use of a key or special knowledge or Ol
effort. � v✓7i
Inspector: BARRY STRATTON-Comments:Front door hardware.
FAIL 901.6-Inspection,testing and Fire detection,alarm,and extinguishing systems,mechanical smoke exhaust
maintenance systems,and smoke and heat vents shall be maintained in an operative condition at
all times,and shall be replaced or repaired where defective.Nonrequired fire
protection systems and equipment shall be inspected,tested and maintained or
removed.
Inspector: BARRY STRATTON-Comments:Sprinkler system needs yearly
maintenance.
FAIL 901.6.1 Standards Fire protection systems shall be inspected,tested and maintained in accordance with
the referenced standards listed in Table .
Inspector: BARRY STRATTON-Comments:Sprinkler
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector: BARRY STRATTON-Comments:Smoke detector in living room is not tied
into bedrooms and the sound of the alarm on detector is not capable of being heard.
FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector: BARRY STRATTON-Comments:Need CO detector installed in vicinity of the
bedrooms.
P-1n;eo on 121 E,: 21`,1 c:35
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may
include boilers,heating equipment,elevator, moving stairways,electrical wiring,and
flammable liquid containers.(IPMC 108.1.2)
Inspector:BARRY STRATTON-Comments:Water heater
FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector: BARRY STRATTON-Comments:Front door to apartment#A
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector: BARRY STRATTON-Comments:Apartment#A needs new front entrance
door installed.Jamb is broken and door does not secure.
FAIL R6.C.-Mechanical Egiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector: BARRY STRATTON-Comments: Discharge tube missing on water heater.
GENERAL NOTES
BARRY STRATTON-12/15/2021 @ 10:28 304.18 Building security. Doors,windows or hatchways for dwelling units, room units
or housekeeping units shall be provided with devices designed to provide security for
the occupants and property within
BARRY STRATTON-12/15/2021 @ 10:29 304.18.1 Doors. Doors providing access to a dwelling unit, rooming unit or
housekeeping unit that is rented, leased or let shall be equipped with a deadbolt lock
designed to be readily openable from the side from which egress is to be made
without the need for keys,special knowledge or effort and shall have a minimum lock
throw of 1 inch(25 mm).Such deadbolt locks shall be installed according to the
manufacturer's specifications and maintained in good working order. For the purpose
of this section,a sliding bolt shall not be considered an acceptable deadbolt lock.
BARRY STRATTON-12/15/2021 @ 10:30 504.3 Plumbing system hazards.Where it is found that a plumbing system in a
structure constitutes a hazard to the occupants or the structure by reason of
inadequate service, inadequate venting,cross connection, backsiphonage, improper
installation,deterioration or damage or for similar reasons,the code official shall
require the defects to be corrected to eliminate the hazard. Kitchen sink is leaking and
water is draining into a bowel.
Pr nted on 12/1512021 a 10:35
Page 2 of 3
'GENERAL NOTES
BARRY STRATTON-12/15/2021 @ 10:33 704.2.2 Interconnection.Where more than one smoke alarm is required to be installed
within an individual dwelling or sleeping unit,the smoke alarms shall be
interconnected in such a manner that the activation of one alarm will activate all of the
alarms in the individual unit. Physical interconnection of smoke alarms shall not be
required where listed wireless alarms are installed and all alarms sound upon
activation of one alarm.The alarm shall be clearly audible in all bedrooms over
background noise levels with all intervening doors closed.
BARRY STRATTON-12/15/2021 @ 10:36 9-7-4 9-7-5: Rental registration is needed for 2021 &2022
RCINSPECTION DATE
01/13/2022
CONTACT SIGNATURE
Elizabeth Parker /a Signed on: 12/15/2021 @ 10:35NIL
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on: 12/15/2021 @ 10:35