Loading...
HomeMy WebLinkAbout2141 LOGAN AVE #5 INVOICE DATE DUE DATE INVOICE# TOTAL DUE r01/13/2022 02/15/2022 2022-00000102 $50.00 Gtertoo ‘° Customer#: 14897 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable VIETH REALTY LLC 715 Mulberry St 6419 NORDIC WATERLOO, IA 50703 CEDAR FALLS, IA 50613 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION- 2141 LOGAN AVE#5 - 1-7-22 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price J REINSPECTION FEE $50.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 14897 01/13/2022 02/15/2022 2022-00000102 $50.00 Less Prepayment $0.00 Total Due $50.00 City of Waterloo \/\. P2A°):G) a\° WATERLOO FIRE RESCUE \ e- pC dtotto INSPECTION REPORT Ctr' tt,) 2141 t�AN AVE,WATERLOO IAsa7r>3 C� \p • <j DETAILS Inspection Date:01/07/2022 1 Inspection Type: Rental Inspection j Inspection Number:7205 I Shift: /A ( Station: N/ I Unit: N/A Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$50.00 0(#_ dJ� STATUS CODE DESCRIPTION FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:BARRY STRATTON-Comments:Front door&jamb needs replaced. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated.Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments:Electrical outlets and switches need covers. Outlets in living room have bad grounds.SEU cables on apartments 2,3,4,&5 need replaced.Electrical boxes pulling off buildings.Need new services for all apartments. Lights hanging by wires.All lights need approved globes. FAIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Inspector:BARRY STRATTON-Comments:Remove extension cords in laundry. Printed on 01/07/2022(1 13:54 Page 1 of 5 STATUS CODE DESCRIPTION FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A,B,E,F, H,I,M,R-1,R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3.In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3315.1.5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON-Comments:Need fire extinguisher in unit. FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector:BARRY STRATTON-Comments:Need smoke detectors in stalled in bedroom and outside of the bedrooms. FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment,elevator,moving stairways,electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector: BARRY STRATTON-Comments:Electric service and gas piping for water heater. FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Inspector:BARRY STRATTON-Comments:Front door and threshold need replaced. Electric service needs replaced on units 2,3,4,&5. FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector:BARRY STRATTON-Comments:Peeling paint,bathroom for needs replaced. Mold present in bathroom. FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(IPMC 602.2) Inspector:BARRY STRATTON-Comments:Need new thermostat on heating device in living room.Can not control heat in unit. Printed on 01/07/2022 13:54 Page 2 of 5 STATUS CODE DESCRIPTION FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector:BARRY STRATTON-Comments:Water heater installed without permits and inspections.Water heater in laundry area does not function. No fan cover on fan in living room#5.Fan does not work.Water heater in laundry needs to have hard pipe for gas line.Appliance gas line in place currently to water heater.Need licensed contractor check water heaters in laundry and unit 5 to ensure installed and safely operating. GENERAL NOTES BARRY STRATTON-01/07/2022 @ 13:49 504.1 General. Plumbing fixtures shall be properly installed and maintained in working order,and shall be kept free from obstructions,leaks and defects and be capable of performing the function for which such plumbing fixtures are designed.Plumbing fixtures shall be maintained in a safe,sanitary and functional condition.Toilet and shower needs replaced.Water valves are leaning in bathroom. Kitchen faucet needs replaced and kitchen drain is leaking. BARRY STRATTON-01/07/2022 @ 13:41 304.13 Window,skylight and door frames. Every window,skylight,door and frame shall be kept in sound condition,good repair and weather tight.Windows need to close and LATCH.Screws are in window track preventing window from latching. BARRY STRATTON-01/07/2022 @ 13:45 9-7-4 9-7-5:2022 Rental registration is needed for all units at fisted address. BARRY STRATTON-01/07/2022 @ 13:45 305.3 Interior surfaces.Interior surfaces,including windows and doors,shall be maintained in good,clean and sanitary condition.Peeling,chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. BARRY STRATTON-01/07/2022 @ 13:46 305.6 Interior doors. Every interior door shall fit reasonably well within its frame and shall be capable of being opened and closed by being properly and securely attached to jambs,headers or tracks as intended by the manufacturer of the attachment hardware. BARRY STRATTON-01/07/2022 @ 13:46 603.1 Mechanical appliances.Mechanical appliances,fireplaces,solid fuel-burning appliances,cooking appliances and water heating appliances shall be properly installed and maintained in a safe working condition,and shall be capable of performing the intended function. P'inted on 01107/2022: 13:54 Page 3 of 5 GENERAL NOTES BARRY STRATTON-01/07/2022 @ 13:48 604.3 Electrical system hazards.Where it is found that the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service,improper fusing,insufficient receptacle and lighting outlets, improper wiring or installation,deterioration or damage,or for similar reasons,the code official shall require the defects to be corrected to eliminate the hazard. Units 2, 3,4,&5 BARRY STRATTON-01/07/2022 @ 13:49 106.4 Violation penalties.Any person who shall violate a provision of this code,or fail to comply therewith,or with any of the requirements thereof,shall be prosecuted within the limits provided by state or local laws. Each day that a violation continues after due notice has been served shall be deemed a separate offense. BARRY STRATTON-01/07/2022 @ 13:51 605.2 Receptacles. Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry area shall contain not less than one grounding-type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain not less than one receptacle.Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection.All receptacle outlets shall have the appropriate faceplate cover for the location. BARRY STRATTON-01/07/2022 @ 13:54 504.3 Plumbing system hazards.Where it is found that a plumbing system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service,inadequate venting, cross connection,backsiphonage, improper installation,deterioration or damage or for similar reasons,the code official shall require the defects to be corrected to eliminate the hazard. BARRY STRATTON-01/07/2022 @ 13:54 R105:Permits and inspections needed for work on all apartments. REINSPECTION GATE 02/07/2022 CONTACT SIGNATURE Vieth Reality LLC Signed on:01/07/2022 @ 13:52 //%L INSPECTOR SIGNATURE BARRY STRATTON Signed on:01/07/2022 @ 13:52 Printed on O1/07/2022 g 13:54 Page 4 of 5 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed on 01107 2022 g 13:54 Page 5 of 5