RENTAL INSPECTION- 2141 LOGAN AVE#5 - 1-7-22 FOR BILLING INQUIRY: (319)291-4323
LDescription Total Price J
REINSPECTION FEE $50.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
14897 01/13/2022 02/15/2022 2022-00000102 $50.00
Less Prepayment $0.00
Total Due $50.00
City of Waterloo
\/\.
P2A°):G)
a\°
WATERLOO FIRE RESCUE \ e- pC dtotto
INSPECTION REPORT Ctr' tt,)
2141 t�AN AVE,WATERLOO IAsa7r>3 C� \p • <j
DETAILS
Inspection Date:01/07/2022 1 Inspection Type: Rental Inspection j Inspection Number:7205 I Shift: /A ( Station: N/ I
Unit: N/A Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$50.00 0(#_ dJ�
STATUS CODE DESCRIPTION
FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector:BARRY STRATTON-Comments:Front door&jamb needs replaced.
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated.Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector:BARRY STRATTON-Comments:Electrical outlets and switches need covers.
Outlets in living room have bad grounds.SEU cables on apartments 2,3,4,&5 need
replaced.Electrical boxes pulling off buildings.Need new services for all apartments.
Lights hanging by wires.All lights need approved globes.
FAIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring.
Extension cords and flexible cords shall not be affixed to structures,extended
through walls,ceilings or floors,or under doors or floor coverings,nor shall such
cords be subject to environmental damage or physical impact. Extension cords shall
be used only with portable appliances.
Inspector:BARRY STRATTON-Comments:Remove extension cords in laundry.
Printed on 01/07/2022(1 13:54
Page 1 of 5
STATUS CODE DESCRIPTION
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new
and existing Group A,B,E,F, H,I,M,R-1,R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A: 10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3.In areas where flammable or combustible
liquids are stored,used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies,in accordance with Section 3315.1.5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRY STRATTON-Comments:Need fire extinguisher in unit.
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector:BARRY STRATTON-Comments:Need smoke detectors in stalled in
bedroom and outside of the bedrooms.
FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may
include boilers,heating equipment,elevator,moving stairways,electrical wiring,and
flammable liquid containers.(IPMC 108.1.2)
Inspector: BARRY STRATTON-Comments:Electric service and gas piping for water
heater.
FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector:BARRY STRATTON-Comments:Front door and threshold need replaced.
Electric service needs replaced on units 2,3,4,&5.
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments:Peeling paint,bathroom for needs
replaced. Mold present in bathroom.
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector:BARRY STRATTON-Comments:Need new thermostat on heating device in
living room.Can not control heat in unit.
Printed on 01/07/2022 13:54
Page 2 of 5
STATUS CODE DESCRIPTION
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector:BARRY STRATTON-Comments:Water heater installed without permits and
inspections.Water heater in laundry area does not function. No fan cover on fan in
living room#5.Fan does not work.Water heater in laundry needs to have hard pipe
for gas line.Appliance gas line in place currently to water heater.Need licensed
contractor check water heaters in laundry and unit 5 to ensure installed and safely
operating.
GENERAL NOTES
BARRY STRATTON-01/07/2022 @ 13:49 504.1 General. Plumbing fixtures shall be properly installed and maintained in working
order,and shall be kept free from obstructions,leaks and defects and be capable of
performing the function for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional condition.Toilet and
shower needs replaced.Water valves are leaning in bathroom. Kitchen faucet needs
replaced and kitchen drain is leaking.
BARRY STRATTON-01/07/2022 @ 13:41 304.13 Window,skylight and door frames. Every window,skylight,door and frame shall
be kept in sound condition,good repair and weather tight.Windows need to close and
LATCH.Screws are in window track preventing window from latching.
BARRY STRATTON-01/07/2022 @ 13:45 9-7-4 9-7-5:2022 Rental registration is needed for all units at fisted address.
BARRY STRATTON-01/07/2022 @ 13:45 305.3 Interior surfaces.Interior surfaces,including windows and doors,shall be
maintained in good,clean and sanitary condition.Peeling,chipping,flaking or abraded
paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood
and other defective surface conditions shall be corrected.
BARRY STRATTON-01/07/2022 @ 13:46 305.6 Interior doors. Every interior door shall fit reasonably well within its frame and
shall be capable of being opened and closed by being properly and securely attached
to jambs,headers or tracks as intended by the manufacturer of the attachment
hardware.
BARRY STRATTON-01/07/2022 @ 13:46 603.1 Mechanical appliances.Mechanical appliances,fireplaces,solid fuel-burning
appliances,cooking appliances and water heating appliances shall be properly
installed and maintained in a safe working condition,and shall be capable of
performing the intended function.
P'inted on 01107/2022: 13:54
Page 3 of 5
GENERAL NOTES
BARRY STRATTON-01/07/2022 @ 13:48 604.3 Electrical system hazards.Where it is found that the electrical system in a
structure constitutes a hazard to the occupants or the structure by reason of
inadequate service,improper fusing,insufficient receptacle and lighting outlets,
improper wiring or installation,deterioration or damage,or for similar reasons,the
code official shall require the defects to be corrected to eliminate the hazard. Units 2,
3,4,&5
BARRY STRATTON-01/07/2022 @ 13:49 106.4 Violation penalties.Any person who shall violate a provision of this code,or fail
to comply therewith,or with any of the requirements thereof,shall be prosecuted
within the limits provided by state or local laws. Each day that a violation continues
after due notice has been served shall be deemed a separate offense.
BARRY STRATTON-01/07/2022 @ 13:51 605.2 Receptacles. Every habitable space in a dwelling shall contain not less than two
separate and remote receptacle outlets. Every laundry area shall contain not less than
one grounding-type receptacle or a receptacle with a ground fault circuit interrupter.
Every bathroom shall contain not less than one receptacle.Any new bathroom
receptacle outlet shall have ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the location.
BARRY STRATTON-01/07/2022 @ 13:54 504.3 Plumbing system hazards.Where it is found that a plumbing system in a
structure constitutes a hazard to the occupants or the structure by reason of
inadequate service,inadequate venting, cross connection,backsiphonage, improper
installation,deterioration or damage or for similar reasons,the code official shall
require the defects to be corrected to eliminate the hazard.
BARRY STRATTON-01/07/2022 @ 13:54 R105:Permits and inspections needed for work on all apartments.
REINSPECTION GATE
02/07/2022
CONTACT SIGNATURE
Vieth Reality LLC
Signed on:01/07/2022 @ 13:52 //%L
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:01/07/2022 @ 13:52
Printed on O1/07/2022 g 13:54