INSPECTION REPORT
1408 WASHINGTON ST,WATERLOO IA 50702 09,
DETAILS
Inspection Date:12/29/2021 I Inspection Type: Rental Inspection I Inspection Number:7041 1 Shift: N/A { Station: N/A I
Unit: N/A Lead Inspector:BARRY STRATTON I Other Inspectors: N/A 1 Fee:$50.00
-9-412€4/4)Ase
STATUS CODE DESCRIPTION
FAIL 507.5.3-Private fire service Private fire service mains and water tanks shall be periodically inspected,tested and
mains and water tanks maintained in accordance with NFPA 25 at the following intervals: 1.Private fire
hydrants of all typelnspection annually and after each operation;flow test and
maintenance annually.2.Fire service main piping: Inspection of exposed,annually;
flow test every 5 years.3.Fire service main piping strainerinspection and
maintenance after each use.Records of inspections,testing and maintenance shall be
maintained,
Inspector:BARRY STRATTON-Comments:481 Days past due on maintenance of
private hydrant.Testing&Maintenance STILL NOT done.
FAIL 901.6.2-Records Records of all system inspections,tests and maintenance required by the referenced
standards shall be maintained.
Inspector:BARRY STRATTON-Comments:481 Days past due on Private Hydrant.
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments:Water damaged drywall in 1st bedroom.
Wall has water damage and mold growth. Remove all damaged drywall and stop
moisture/water then replace drywall.Closet doors in living room and 1st bedroom
falling off tracks and doors do not function.Mice need exterminated.Carpet in
hallway and living room has water damage. Remove damaged carpet and replace.
Bathroom floor has water damage.Remove ail damaged flooring and replace.
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector:BARRY STRATTON-Comments:Mold
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector: BARRY STRATTON-Comments:Heat registers hanging from ceiling and
need installed to manufactures specifications.Vent could fall off ceiling.
P-Inted on 12/29,2021 12.39
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector:BARRY STRATTON-Comments:Exhaust fan over stove does not work and
needs replaced.Some Burners on stove do not work.
GENERAL NOTES
BARRY STRATTON-12/29/2021 @ 12:36 504.1 General.Plumbing fixtures shall be properly installed and maintained in working
order,and shall be kept free from obstructions, leaks and defects and be capable of
performing the function for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional condition.Toilet needs
reset on floor and need new wax ring installed.Kitchen sink is leaking and catching
water in a bucket.
BARRY STRATTON-12/29/2021 @ 12:36 304.14 Insect screens.During the period from[DATE}to[DATE},every door,window
and other outside opening required for ventilation of habitable rooms,food
preparation areas,food service areas or any areas where products to be included or
utilized in food for human consumption are processed, manufactured,packaged or
stored shall be supplied with approved tightly fitting screens of minimum 16 mesh per
inch(16 mesh per 25 mm),and every screen door used for insect control shall have a
self-closing device in good working condition.Need window screens on all windows.
Some screens broken and some missing.
BARRY STRATTON-12/29/2021 @ 12:36 304.13 Window,skylight and door frames. Every window,skylight,door and frame shall
be kept in sound condition,good repair and weather tight.Windows have condensate
build up on windows from poor air quality. Mold/Mildew forming on frame/tracks of
windows.
BARRY STRATTON-12/29/2021 @ 12:36 305.4 Stairs and walking surfaces. Every stair,ramp,landing,balcony,porch,deck or
other walking surface shall be maintained in sound condition and good repair.
BARRY STRATTON-12/29/2021 @ 12:37 305.6 Interior doors.Every interior door shall fit reasonably well within its frame and
shall be capable of being opened and closed by being properly and securely attached
to jambs, head
BARRY STRATTON-12/29/2021 @ 12:37 309.1 Infestation.Structures shall be kept free from insect and rodent infestation.
Structures in which insects or rodents are found shall be promptly exterminated by
approved processes that will not be injurious to human health.After pest elimination,
proper precautions shall be taken to prevent re-infestation.
Printed on 12,29/2021 2 12:39
Page 2 of 3
GENERAL NOTES
BARRY STRATTON-12/29/2021 @ 12:37 305.3 Interior surfaces. Interior surfaces,including windows and doors,shall be
maintained in good,clean and sanitary condition.Peeling,chipping,flaking or abraded
paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood
and other defective surface conditions shall be corrected.
BARRY STRATTON-12/29/2021 @ 12:37 403.6 Mold Present In A Rental Unit.a.When mold is found to be visibly present in
small amounts,it can be cleaned in a safe and sanitary manner.b.When mold is found
in a rental unit and is determined to be a health risk,the building official may order
that a clean air report be obtained from a mold specialist approved by the building
official.
BARRY STRATTON-12/29/2021 @ 12:39 106.4 Violation penalties.Any person who shall violate a provision of this code,or fail
to comply therewith,or with any of the requirements thereof,shall be prosecuted
within the limits provided by state or local laws. Each day that a violation continues
after due notice has been served shall be deemed a separate offense.
REINSPECTION DATE
01/31/2022
CONTACT SIGNATURE
John Foley ZAAiL
Signed on:12/29/2021 @ 12:37
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:12/29/2021 @ 12:38