HomeMy WebLinkAbout502 INDEPENDENCE AVE c\jc? WATERLOO FIRE RESCUE - ,f ,� � . j•-• j4; INSPECTION REPORT � '� ��. SO2 INDEPENDENCE AVE,WATERLOO IA S0703 ' \V DETAILS Inspection Date:12/01/2021 Inspection Type:Complaint Inspection Number:6896 Shift: N/A l Station: N/A ; Unit: N/A Lead Inspector:BARRY STRATTON j Other Inspectors: N/A 1 Fee:$50.00 4,401 STATUS CODE DESCRIPTION FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:BARRY STRATTON-Comments:Egress path blocked at front entrance. Furniture and debris in hallway causing obstructions. Debris in basement has not been removed. FAIL 9-Complaint Field Upon visual inspection does situation match the complaints concerns?Fail to Verification indicate that the complaint was found to be valid and use the codes tab to document what violations were noted.If no violations are noted, pass and use the notes section to indicate that no evidence of the complaints concerns were found. Inspector: BARRY STRATTON-Comments:Egress path blocked. FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector:BARRY STRATTON-Comments:Smoke detectors needed to be installed to meet code requirements.Smoke detectors also required in basement. FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector:BARRY STRATTON-Comments: GENERAL NOTES BARRY STRATTON-12/01/2021 @ 10:14 304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition. Handrail is also missing to basement. Printed on 2,01/2021 L 10:17 Page 1 of 2 GENERAL NOTES BARRY STRATTON-12/01/2021 @ 10:16 605.1 Installation. Electrical equipment,wiring and appliances shall be properly installed and maintained in a safe and approved manner. Need clear path to electrical panels in basement. R€ENSP€CTION DATE 01/03/2022 CONTACT SIGNATURE Noe Sibrian Signed on:12/01/2021 @ 10:16 \L INSPECTOR SIGNATURE BARRY STRATTON Signed on:12/01/2021 @ 10:16 QUESTIONS ABUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Pr Cited or 1:01 20:1 ='0:'i Page 2 of 2