HomeMy WebLinkAbout201 ALLEN ST Pof WATERLOO FIRE RESCUE ,„,ko-9P) � 4i IHSPEr� REPORT�� � � �s � 201 ALLEN Sr WATERLt IA 50701 \ DETAILS Inspection Date: 12/29/2021 I Inspection Type: Rental Inspection 1 Inspection Number:7037 I Shift: N/A I Station: N/A I Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$50.00 / fit r .9%°' STATUS CODE DESCRIPTION FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Inspector:BARRY STRATTON-Comments:Doors broken FAIL 1031.7-Emergency escape Required emergency escape and rescue openings shall be maintained in accordance and rescue openings with the code in effect at the time of construction,and the following:Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools.Bars,grilles,grates or similar devices are allowed to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key,tool or force greater than that which is required for normal operation of the emergency escape and rescue opening. Inspector:BARRY STRATTON-Comments:Windows FAIL 605.1 -Abatement of Identified electrical hazards shall be abated.Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments:Electrical system has breakers that continue to trip.have panel and breakers checked by licensed professional FAIL 703.2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with NFPA 80.Where allowed by the fire code official,the application of field-applied labels associated with the maintenance of opening protectives shall follow the requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged.Fire door assemblies shall not be modified. Inspector:BARRY STRATTON-Comments:Windows Printed an 12/29/2021 Ez 10:34 Page 1 of 5 STATUS CODE DESCRIPTION FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A,B,E,F, H,I,M,R-1,R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3315.1.5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector:BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector:BARRY STRATTON-Comments:Smoke detectors are needed in each bedroom and outside of the bedrooms.Also smoke detector is needed in basement. FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector:BARRY STRATTON-Comments:CO detectors are needed in vicinity of the bedrooms. FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC Occupancy 108.1.3) Inspector:BARRY STRATTON-Comments:Condition of unit and lack of maintenance to unit. FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This includes grading and drainage,sidewalks and driveways,weeds,and pest infestations.(IPMC 302) Inspector:BARRY STRATTON-Comments: FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Inspector:BARRY STRATTON-Comments:Windows&Doors Printed on 12/29/2021 10:34 Page 2 of 5 STATUS CODE DESCRIPTION FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector:BARRY STRATTON-Comments:Ceilings in living room&dining room have fallen in and are still not repaired/replaced.Walls are cracked,holes in walls,mold present,broken windows,floors,tub faucet needs replaced and peeling paint. FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector:BARRY STRATTON-Comments:Uninhabitable because of the lack of maintenance to unit. GENERAL NOTES BARRY STRATTON-12/29/2021 @ 10:31 108.1.3 Structure unfit for human occupancy.A structure is unfit for human occupancy whenever the code official finds that such structure is unsafe,unlawful or,because of the degree to which the structure is in disrepair or lacks maintenance,is insanitary, vermin or rat infested,contains filth and contamination,or lacks ventilation, illumination,sanitary or heating facilities or other essential equipment required by this code,or because the location of the structure constitutes a hazard to the occupants of the structure or to the public. BARRY STRATTON-12/29/2021 @ 10:31 102.2 Maintenance. Equipment,systems,devices and safeguards required by this code or a previous regulation or code under which the structure or premises was constructed,altered or repaired shall be maintained in good working order. No owner, owners authorized agent,operator or occupant shall cause any service,facility, equipment or utility that is required under this section to be removed from,shut off from or discontinued for any occupied dwelling,except for such temporary interruption as necessary while repairs or alterations are in progress.The requirements of this code are not intended to provide the basis for removal or abrogation of fire protection and safety systems and devices in existing structures. Except as otherwise specified herein,the owner or the owner's authorized agent shall be responsible for the maintenance of buildings,structures and premises. BARRY STRATTON-12/29/2021 @ 10:32 Rental unit need total gut/remodel to meet occupancy requirements. BARRY STRATTON-12/29/2021 @ 10:32 102.5 Workmanship. Repairs,maintenance work,alterations or installations that are caused directly or indirectly by the enforcement of this code shall be executed and installed in a workmanlike manner and installed in accordance with the manufacturer's instructions. Printed on 12/29/2021 10:34 Page 3 of 5 GENERAL NOTES BARRY STRATTON-12/29/2021 @ 10:32 403.6 Mold Present In A Rental Unit,a.When mold is found to be visibly present in small amounts,it can be cleaned in a safe and sanitary manner.b.When mold is found in a rental unit and is determined to be a health risk,the building official may order that a clean air report be obtained from a mold specialist approved by the building official. BARRY STRATTON-12/29/2021 @ 10:32 108.1.5 Dangerous structure or premises. For the purpose of this code,any structure or premises that has any or all of the conditions or defects described below shall be considered dangerous:6.The building or structure, or any portion thereof, is clearly unsafe for its use and occupancy. BARRY STRATTON-12/29/2021 @ 10:32 309.1 Infestation.Structures shall be kept free from insect and rodent infestation. Structures in which insects or rodents are found shall be promptly exterminated by approved processes that will not be injurious to human health.After pest elimination, proper precautions shall be taken to prevent re-infestation.Mice,flies,gnats, cockroaches. BARRY STRATTON-12/29/2021 @ 10:33 309.2 Owner.The owner of any structure shall be responsible for pest elimination within the structure prior to renting or leasing the structure. BARRY STRATTON-12/29/2021 @ 10:33 106.4 Violation penalties.Any person who shall violate a provision of this code,or fail to comply therewith,or with any of the requirements thereof,shall be prosecuted within the limits provided by state or local laws. Each day that a violation continues after due notice has been served shall be deemed a separate offense. REINSPECTION DATE 01/31/2022 CONTACT SIGNATURE Properties For You II Signed on:12/29/2021 @ 10:34 INSPECTOR SIGNATURE BARRY STRATTON Signed on:12/29/2021 @ 10:34 Printed an 12/29/2021 10.34 Page 4 of 5