HomeMy WebLinkAbout320 DENVER ST / , WATERLOO FIRE RESCUE of a 4, INSPECTION REPORT \ `�1e--) � 1:01. 320 DENVER ST, WATERLOO IA 50701 O �DETAILS Inspection Date:02/09/2022 I Inspection Type: Rental Inspection I Inspection Number:7229 I Shift: /A f Station: N A 1 Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$50.00 i,4111 x ,4 STATUS CODE DESCRIPTION FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments:Electrical system. Furnace installed without permits and inspections. FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A, B, E, F, H,I,M,R-1, R-2,R-4 and S occupancies. Exception: In Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3315.1.5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector: BARRY STRATTON-Comments: FAIL R1 -Unsafe Structures Is the structure found to be dangerous to the life,health, property or safety of either the public or occupants of the structure?(IPMC 108.1.1) Inspector:BARRY STRATTON-Comments:Sewage in basement and outside in yard. FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment,elevator,moving stairways,electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector: BARRY STRATTON-Comments:Furnace and water heater.NO permits or inspections for both Printed on O2,0S,2022 Lt.13.23 Page 1 of 4 . STATUS CODE DESCRIPTION FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC Occupancy 108.1.3) Inspector: BARRY STRATTON-Comments:Raw sewage in basement FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair, structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments: No hot water in house. Bath tub not draining. FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector: BARRY STRATTON-Comments:Sewage in basement and outside in yard. FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(IPMC 602.2) Inspector:BARRY STRATTON-Comments:No permits or inspections on furnace. FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector: BARRY STRATTON-Comments:Water heater not providing hot water to house. GENERAL NOTES BARRY STRATTON-02/09/2022 @ 13:26 504.1 General.Plumbing fixtures shall be properly installed and maintained in working order,and shall be kept free from obstructions,leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe,sanitary and functional condition. BARRY STRATTON-02/09/2022 @ 13:26 504.3 Plumbing system hazards.Where it is found that a plumbing system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, inadequate venting, cross connection, backsiphonage, improper installation,deterioration or damage or for similar reasons,the code official shall require the defects to be corrected to eliminate the hazard. Printed on 02/09/2022 Le:t 3'23 Page 2 of 4 t r GENERAL NO ES BARRY STRATTON-02/09/2022 @ 13:26 505.4 Water heating facilities.Water heating facilities shall be properly installed, maintained and capable of providing an adequate amount of water to be drawn at every required sink, lavatory,bathtub,shower and laundry facility at a minimum temperature of 110°F(43°C).A gas-burning water heater shall not be located in any bathroom,toilet room,bedroom or other occupied room normally kept closed,unless adequate combustion air is provided.An approved combination temperature and pressure-relief valve and relief valve discharge pipe shall be properly installed and maintained on water heaters. BARRY STRATTON-02/09/2022 @ 13:26 506.1 General.Plumbing fixtures shall be properly connected to either a public sewer system or to an approved private sewage disposal system. BARRY STRATTON-02/09/2022 @ 13:26 603.1 Mechanical appliances.Mechanical appliances,fireplaces,solid fuel-burning appliances,cooking appliances and water heating appliances shall be properly installed and maintained in a safe working condition,and shall be capable of performing the intended function. Furnace not installed to meet code. No permits/Inspections. BARRY STRATTON-02/09/2022 @ 13:27 604.3.2.1 Electrical equipment. Electrical switches,receptacles and fixtures,including furnace,water heating,security system and power distribution circuits,that have been exposed to fire,shall be replaced in accordance with the provisions of the International Building Code. BARRY STRATTON-02/09/2022 @ 13:27 605.1 Installation. Electrical equipment,wiring and appliances shall be properly installed and maintained in a safe and approved manner. BARRY STRATTON-02/09/2022 @ 13:27 IPMC 106.4:Violation penalties.Any person who shall violate a provision of this code, or fail to comply therewith,or with any of the requirements thereof,shall be prosecuted within the limits provided by state or local laws. Each day that a violation continues after due notice has been served shall be deemed a separate offense. BARRY STRATTON-02/09/2022 @ 13:27 9-5-6:APPLICATION FOR PERMIT:A. Permit To Do Work Required:It shall be unlawful for any person to construct or install any fuel burning, space heating,air conditioning or incinerator equipment or appurtenances subject to and covered by the provisions of this chapter in or for any building or to alter,repair or convert any such existing fuel burning,space heating,air conditioning or incinerator equipment or appurtenances as are subject to the provisions of this chapter without first making written application for a permit therefor setting forth the nature and extent of the work to be performed. (Ord.5392,3-20-2017)Citation$500.00+95,00 Court Costs BARRY STRATTON-02/09/2022 @ 13:27 9-5-8:NOTIFICATION FOR INSPECTION:Licensed contractor shall be obtained. Printeei on 02,09,2022 a^a 13:28 Page 3 of 4 RE INSPECTION DATE 03/09/2022 CONTACT SIGNATURE Doris Ruffridge L.AAA Signed on:02/09/2022 @ 13:28 INSPECTOR SIGNATURE BARRY STRATTON Signed on:02/09/2022 @ 13:28 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed on 02,03/2022 4-13 23 Page 4 of 4