DETAILS
Inspection Date:01/28/2022 1 Inspection Type: Rental Inspection I Inspection Number:7173 I Shit: A I Station: N/A
Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$50.00 4/ , _�f�
STATUS CODE DESCRIPTION
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector: BARRY STRATTON-Comments:Outlets not grounded in living room&
Kitchen.Switch by stairs pulling out of wall.Need cover for 220 V dryer outlet that
currently has exposed wires.Globes are needed on light fixtures.Corrections not
done. No re-inspections been scheduled and house has new tenants.
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new
and existing Group A, B, E,F,H,I,M,R-1,R-2,R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-8:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3. In areas where flammable or combustible
liquids are stored,used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies,in accordance with Section 3315.1.5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRY STRATTON-Comments:
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector:BARRY STRATTON-Comments:Smoke detectors are needed in each
bedroom and outside of the bedrooms.Smoke detectors are also needed in attic and
basement.
FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 1103.9.
Inspector:BARRY STRATTON-Comments:
P"inted on 01/2312022 3 10:23
Page 1 of 4
STATUS CODE DESCRIPTION
FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may
include boilers,heating equipment,elevator,moving stairways,electrical wiring,and
flammable liquid containers.(IPMC 108.1.2)
Inspector:BARRY STRATTON-Comments:Electric
FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector:BARRY STRATTON-Comments:Need window screens in place where
missing. Need to replace all broken windows. Rear deck needs repaired.Stairs are
pulling away from deck and need handrail on stairs leading to yard. Roof needs
replaced and gutters need installed where missing
FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments:Holes in walls,peeling paint,floor&
subfloor in bathroom needs replaced,attic floor is unsafe,kitchen hood is falling off
cabinet.Shower head and pipe not strapped in place and can pull out of wall.Tub
surround needs replaced. Mice feces present in kitchen cabinets.
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector:BARRY STRATTON-Comments:No cover on 220 V dryer outlet
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector:BARRY STRATTON-Comments:Water heater not installed with permits and
inspections.Supply lines not to code. PEX lines supplied to top of gas water heater.
Need licensed professional to obtain permits and inspections.Supply line for shower
needs secured/strapped in wall to prevent breakage.Hood over stove in kitchen is
falling off cabinets.Central AC unit is installed and not working. Disconnect is missing
breaker and top of AC is loose and missing screws holding together.
GENERAL NOTES
BARRY STRATTON-01/28/2022 @ 10:20 304.10 Stairways,decks,porches and balconies. Every exterior stairway,deck,porch
and balcony,and all appurtenances attached thereto,shall be maintained structurally
sound,in good repair,with proper anchorage and capable of supporting the imposed
loads.Corrections not done.
Ptinted on O1/2812O22 @ 10:23
Page 2 of 4
GENERAL NOTES
BARRY STRATTON-01/28/2022 @ 10:21 304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and
capable of supporting normally imposed loads and shall be maintained in good
condition.
BARRY STRATTON-01/28/2022 @ 10:21 304.13.2 Openable windows. Every window,other than a fixed window,shall be easily
openable and capable of being held in position by window hardware.
BARRY STRATTON-01/28/2022 @ 10:21 304.14 Insect screens
BARRY STRATTON-01/28/2022 @ 10:21 305.3 Interior surfaces. Interior surfaces,including windows and doors,shall be
maintained in good,clean and sanitary condition.Peeling,chipping,flaking or abraded
paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood
and other defective surface conditions shall be corrected.
BARRY STRATTON-01/28/2022 @ 10:21 305.4 Stairs and walking surfaces. Every stair,ramp,landing,balcony,porch,deck or
other walking surface shall be maintained in sound condition and good repair.
BARRY STRATTON-01/28/2022 @ 10:22 504.1 General. Plumbing fixtures shall be properly installed and maintained in working
order,and shall be kept free from obstructions, leaks and defects and be capable of
performing the function for which such plumbing fixtures are designed. Plumbing
fixtures shall be maintained in a safe,sanitary and functional condition.
BARRY STRATTON-01/28/2022 @ 10:22 505.4 Water heating facilities.Water heating facilities shall be properly installed,
maintained and capable of providing an adequate amount of water to be drawn at
every required sink,lavatory, bathtub,shower and laundry facility at a minimum
temperature of 110°F(43°C).A gas-burning water heater shall not be located in any
bathroom,toilet room,bedroom or other occupied room normally kept closed, unless
adequate combustion air is provided.An approved combination temperature and
pressure-relief valve and relief valve discharge pipe shall be properly installed and
maintained on water heaters.
BARRY STRATTON-01/28/2022 @ 10:22 604.3 Electrical system hazards.Where it is found that the electrical system in a
structure constitutes a hazard to the occupants or the structure by reason of
inadequate service,improper fusing, insufficient receptacle and lighting outlets,
improper wiring or installation,deterioration or damage,or for similar reasons,the
code official shall require the defects to be corrected to eliminate the hazard.
R€tNSPZCTION DATE
02/25/2022