HomeMy WebLinkAbout1211 LAFAYETTE ST (2) WATERLOO FIRE RESCUE
cskLANIA-'\
INSPECTION REPORTZ
1211 LAFAYETTE ST,WATERLOO IA 5 703
\L \CI
DETAILS
Inspection Date:01/28/2022 ( Inspection Type:Rental Inspection ( Inspection Number:7174 ( Shift: NI ( Station: N/A I
Unit: N/A ( Lead Inspector:BARRY STRATTON ( Other Inspectors: N/A ( Fee:$50.00 , jd�
STATUS CODE DESCRIPTION
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector:BARRY STRATTON-Comments:Exterior lights
FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector:BARRY STRATTON-Comments:
FAIL R1 -Unsafe Structures Is the structure found to be dangerous to the life,health, property or safety of either
the public or occupants of the structure?(IPMC 108.1.1)
Inspector:BARRY STRATTON-Comments:Foundation&house
FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC
Occupancy 108.1.3)
Inspector:BARRY STRATTON-Comments:Several structural issues and fire safety
issues.
FAIL R4-Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,and pest
infestations.(IPMC 302)
Inspector:BARRY STRATTON-Comments:Debris
FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Printed an 01/2812022(�10:10
Page 1 of 3
STATE CODE DESCRIPTION
Inspector:BARRY STRATTON-Comments:Foundation,exterior treatment, roof,
decks,stairs,landings,windows.
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector:BARRY STRATTON-Comments:Foundation damage, missing foundation,
potential damage to gas line.
GENERAL NOTES
BARRY STRATTON-01/28/2022 @ 10:08 108.1.1 Unsafe structures.An unsafe structure is one that is found to be dangerous to
the life,health,property or safety of the public or the occupants of the structure by
not providing minimum safeguards to protect or warn occupants in the event of fire,
or because such structure contains unsafe equipment or is so damaged,decayed,
dilapidated,structurally unsafe or of such faulty construction or unstable foundation,
that partial or complete collapse is possible
BARRY STRATTON-01/28/2022 @ 10:08 108.1.3 Structure unfit for human occupancy.A structure is unfit for human occupancy
whenever the code official finds that such structure is unsafe,unlawful or,because of
the degree to which the structure is in disrepair or lacks maintenance,is insanitary,
vermin or rat infested,contains filth and contamination,or lacks ventilation,
illumination,sanitary or heating facilities or other essential equipment required by this
code,or because the location of the structure constitutes a hazard to the occupants of
the structure or to the public
BARRY STRATTON-01/28/2022 @ 10:09 108.1.5 Dangerous structure or premises.For the purpose of this code,any structure
or premises that has any or all of the conditions or defects described below shall be
considered dangerous:5.The building or structure,or part of the building or
structure, because of dilapidation,deterioration,decay,faulty construction,the
removal or movement of some portion of the ground necessary for the support,or for
any other reason, is likely to partially or completely collapse,or some portion of the
foundation or underpinning of the building or structure is likely to fail or give way.6.
The building or structure,or any portion thereof,is clearly unsafe for its use and
occupancy
BARRY STRATTON-01/28/2022 @ 10:09 304.2 Protective treatment. Exterior surfaces,including but not limited to,doors,door
and window frames,cornices,porches,trim,balconies,decks and fences,shall be
maintained in good condition. Exterior wood surfaces,other than decay-resistant
woods,shall be protected from the elements and decay by painting or other protective
covering or treatment. Peeling,flaking and chipped paint shall be eliminated and
surfaces repainted.Siding and masonry joints,as well as those between the building
envelope and the perimeter of windows,doors and skylights,shall be maintained
weather resistant and water tight. Metal surfaces subject to rust or corrosion shall be
coated to inhibit such rust and corrosion,and surfaces with rust or corrosion shall be
stabilized and coated to inhibit future rust and corrosion.Oxidation stains shall be
removed from exterior surfaces.Surfaces designed for stabilization by oxidation are
exempt from this requirement.
Printed on 01128)2022 E.10:10
Page 2 of 3
GENERAL NOTES
BARRY STRATTON-01/28/2022 @ 10:09 304.5 Foundation walls. Foundation walls shall be maintained plumb and free from
open cracks and breaks and shall be kept in such condition so as to prevent the entry
of rodents and other pests
BARRY STRATTON-01/28/2022 @ 10:09 304.6 Exterior walls. Exterior walls shall be free from holes, breaks,and loose or rotting
materials;and maintained weatherproof and properly surface coated where required
to prevent deterioration.
BARRY STRATTON-01/28/2022 @ 10:09 308.1 Accumulation of rubbish or garbage. Exterior property and premises,and the
interior of every structure,shall be free from any accumulation of rubbish or garbage.
BARRY STRATTON-01/28/2022 @ 10:10 R105:No permits for work being done.
BARRY STRATTON-01/28/2022 @ 10:10 106.4 Violation penalties.Any person who shall violate a provision of this code,or fail
to comply therewith,or with any of the requirements thereof,shall be prosecuted
within the limits provided by state or local laws. Each day that a violation continues
after due notice has been served shall be deemed a separate offense.
REINSPECTION DATE
02/25/2022
CONTACT SIGNATURE
KA Investments LLC //ys\\\
Signed on:01/28/2022 @ 10:10
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:01/28/2022 @ 10:10
QUESTIONS ABOUT YOUR INSPECTION?
BARRY STRATTON
barry.stratton@waterloo-ia.org
(319)231-9147
Printed on 01/28/2022 g 10:10