HomeMy WebLinkAbout1047 LANGLEY RD f n, WATERLOO FIRE RESCUE ' -'-ijer/11 .144174 .itoky INSPECTION REPORT .(1):# 11!047 LANGLEY RD,WATERLOO La S0702 )S5 ( L) � ,, ,,I\601/Lincik-e,' /1--<-s,- 56 0(/(I DETAILS Inspection Date:01/27/2022 I Inspection Type: Rental Inspection I Inspection Number:7168 ( hift• /A [ Station: IA I Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A l Fee:$50.00 ?goy ,4 — fja STATUS CODE DESCRIPTION FAIL 1008.1 -Means of egress Illumination shall be provided in the means of egress in accordance with Section illumination 1008.2. Under emergency power, means of egress illumination shall comply with Section 1008.3. Inspector:BARRY STRATTON-Comments:Egress/exit sign at front entrance the egress light was not working.Still not working at time of today's inspection. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments:Breakers trip out in breaker panel.Breaker tripped out in panel at time of inspection. FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON-Comments:Smoke detectors in hallway was missing. FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector: BARRY STRATTON-Comments: FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment,elevator,moving stairways,electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector:BARRY STRATTON-Comments:No hot water.Was water heater replaced or repaired? Printed on O1/27 2O22 @ 13:29 Page 1 of 3 STATUS CODE DESCRIPTION FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector: BARRY STRATTON-Comments:Holes in walls need repaired.Window on rear of apartment was screwed shut. FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector:BARRY STRATTON-Comments:No hot water FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(IPMC 602.2) Inspector:BARRY STRATTON-Comments:602.2 Residential occupancies. Dwellings shall be provided with heating facilities capable of maintaining a room temperature of 68°F(20°C)in all habitable rooms,bathrooms and toilet rooms based on the winter outdoor design temperature for the locality indicated in Appendix D of the International Plumbing Code.Cooking appliances shall not be used,nor shall portable unvented fuel-burning space heaters be used,as a means to provide required heating. FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector: BARRY STRATTON-Comments:505.4 Water heating facilities.Water heating facilities shall be properly installed,maintained and capable of providing an adequate amount of water to be drawn at every required sink,lavatory,bathtub, shower and laundry facility at a minimum temperature of 110°F(43°C).A gas-burning water heater shall not be located in any bathroom,toilet room,bedroom or other occupied room normally kept closed,unless adequate combustion air is provided.An approved combination temperature and pressure-relief valve and relief valve discharge pipe shall be properly installed and maintained on water heaters. No hot water in unit#3 for the month of December. Need to Correct ASAP.24 HR EMERGENCY Repair notice on hot water issue. GENERAL NOTES BARRY STRATTON-01/27/2022 @ 13:27 106.4 Violation penalties.Any person who shall violate a provision of this code,or fail to comply therewith,or with any of the requirements thereof,shall be prosecuted within the limits provided by state or local laws. Each day that a violation continues after due notice has been served shall be deemed a separate offense.If new water heater was installed it did not have permits and inspections. Pr nted on O/2712J22;^e-13:29 Page 2 of 3 GENERAL NOTES BARRY STRATTON-01/27/2022 @ 13:29 304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition.These items are still needed for rear entrance. REINSPECTION DATE 02/24/2022 CONTACT SIGNATURE EPM Iowa ' Signed on:01/27/2022 @ 13:27 AA b._ INSPECTOR SIGNATURE BARRY STRATTON Signed on:01/27/2022 @ 13:27 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed an 01127/2022 i s 13:29 Page 3 of 3