HomeMy WebLinkAbout2715 ST FRANCIS DR , , d ,,,,ai_ WATERLOO FIRE RESCUE sOC\ op(-)\ vo,k,o(k0 23' " _ �,,\ INSPECTION REPORT r ��2715 ST FRANCIS D WATERLOO "S0fi rV1- I:0' )� DETAILS LaD Q { t, Inspection Date:01/19/2022 I Inspection Type: Rental Inspection I Inspection Number:7254 1 Shift: N/A I Station: A I Unit: N/A 1 Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$50.00 /al, STATUS CODE DESCRIPTION FAIL 505.1 -Address identification New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property.Address identification characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out.Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 1/2(12.7 mm). Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector:BARRY STRATTON-Comments:Need a posted address on front of building. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments:Electrical switches with damage need replaced.Switches have sparked and caused damage to walls. FAIL. 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector:BARRY STRATTON-Comments:Ensure detectors are installed to meet city rental code. FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment,elevator,moving stairways,electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector:BARRY STRATTON-Comments:Hot water heater. FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Printed an 01/19/2022 @ 13.54 Page 1 of 3 STATUS CODE DESCRIPTION Inspector:BARRY STRATTON-Comments:Front steps need replaced.handrailing not attached to steps and not capable of preforming intended function.Need new handrail installed on front steps. FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector:BARRY STRATTON-Comments:Hot water heater not providing hot water. GENERAL NOTES BARRY STRATTON-01/19/2022 @ 13:49 304.3 Premises identification. Buildings shall have approved address numbers placed in a position to be plainly legible and visible from the street or road fronting the property.These numbers shall contrast with their background.Address numbers shall be Arabic numerals or alphabet letters.Numbers shall be not less than 4 inches(102 mm)in height with a minimum stroke width of 0.5 inch(12.7 mm). BARRY STRATTON-01/19/2022 @ 13:50 304.10 Stairways,decks,porches and balconies.Every exterior stairway,deck,porch and balcony,and all appurtenances attached thereto,shall be maintained structurally sound,in good repair,with proper anchorage and capable of supporting the imposed loads. BARRY STRATTON-01/19/2022 @ 13:50 304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition. BARRY STRATTON-01/19/2022 @ 13:52 9-7-4 9-7-5:2022 Rental registration is needed.Unit has not been registered since 2017. Citation(s)for$500.00+$95.00+595.00 for failure to register all rental units in Waterloo.(2707&2715 St, Francis Dr.) BARRY STRATTON-01/19/2022 @ 13:53 Our office will need contact information for all rental properties in Waterloo.Our local dispatch center will also require information on who to contact incase of an emergency. REINSPECTION DATE 02/16/2022 Printed an 01/1912022 g,13:54 Page 2 of 3 CONTACT SIGNATURE UNIVERSAL ACCESS MORT MIDWEST LL Signed on:01/19/2022 @ 13:52 L INSPECTOR SIGNATURE BARRY STRATTON Signed on:01/19/2022 @ 13:52 QUESTIONS ABOUT YOUR INSPECTION? .. BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed an 01/19/2022 t$'13:54 Page 3 of 3