HomeMy WebLinkAbout200 INDEPENDENCE AVE '')\ L',1. ),Tx1S-1 Cief\-c __,-- WATERLOO FIRE RESCUE . .5) oattz, . 1.(Thl INSPECTION REPORT Y 0 2 â–ºINDEPENDENCEAVE,WATERLOO 50703 AAil DETAILS ° Inspection Date:01/26/2022 I Inspection Type: Rental Inspection 1 Inspection Number:7014 ( S ift: NIA 6 Station: N/A I 79.0 Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$50.00 , / ,_)- (r)O STATUS CODE DESCRIPTION FAIL 1010.1.9-Door operations Except as specifically permitted by this section,egress doors shall be readily operable from the egress side without the use of a key or special knowledge or effort. Inspector:BARRY STRATTON-Comments:Front and rear doors need replaced. Door hardware missing and some security hardware around jambs are broken, missing. Door hardware missing on bathroom door. Front door hinges are not set in jamb and door not secure in jamb.Threshold in jamb is rotten. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments:Several outlets can not be plugged into. Electric panel in basement missing cover.220V dryer outlet not working. Electric panel has neutrals and grounds together,each need there own bar. Kitchen outlets not working and refrigerator plugged into extension cord running to basement. Appliances need direct connection to outlet. Have licensed electric professional replace outlets,dryer outlet and electric panel corrections. No permits obtained yet for corrections to be corrected. FAIL 605.5-Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Inspector: BARRY STRATTON-Comments: Prated on 01 25'2022 09:40 Page 1 of 4 i s STATUS CODE DESCRIPTION FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1. In new and existing Group A, B,E, F, H, I,M, R-1,R-2,R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector:BARRY STRATTON-Comments: FAR. R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector:BARRY STRATTON-Comments:Holes in walls,kitchen sink cabinet needs replaced,kitchen ceiling has holes, Kitchen cabinets missing doors,broken basement windows, replace all broken glass.float in toilet needs replaced.Peeling and abraded paint throughout. FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector:BARRY STRATTON-Comments:Bathroom mold/walls water damage FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room temperature of 68F?(IPMC 602.2) Inspector:BARRY STRATTON-Comments:Missing register covers and no inspection done on new furnace. FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working condition?(IPMC 603.1) Inspector: BARRY STRATTON-Comments:Water heater installed with out permits and inspections. GENERAL NOTES BARRY STRATTON-01/26/2022 @ 09:37 304.13 Window,skylight and door frames.Every window,skylight,door and frame shall be kept in sound condition,good repair and weather tight. Printed on 01/25t2022 09:40 Page 2 of 4 r SINEW.NOTES BARRY STRATTON-01/26/2022 @ 09:37 304.18 Building security. Doors,windows or hatchways for dwelling units, room units or housekeeping units shall be provided with devices designed to provide security for the occupants and property within.304.18.1 Doors. Doors providing access to a dwelling unit, rooming unit or housekeeping unit that is rented,leased or let shall be equipped with a deadbolt lock designed to be readily openable from the side from which egress is to be made without the need for keys,special knowledge or effort and shall have a minimum lock throw of 1 inch(25 mm),Such deadbolt locks shall be installed according to the manufacturer's specifications and maintained in good working order. For the purpose of this section,a sliding bolt shall not be considered an acceptable deadbolt lock. Hinges not secure door and jamb. BARRY STRATTON-01/26/2022 @ 09:37 504.1 General. Plumbing fixtures shall be properly installed and maintained in working order,and shall be kept free from obstructions, leaks and defects and be capable of performing the function for which such plumbing fixtures are designed. Plumbing fixtures shall be maintained in a safe,sanitary and functional condition. Bathroom shower needs new surround and new faucet/shower head installed on tub.Toilet also needs new float installed in toilet. BARRY STRATTON-01/26/2022 @ 09:38 605.1 Installation. Electrical equipment,wiring and appliances shall be properly installed and maintained in a safe and approved manner. BARRY STRATTON-01/26/2022 @ 09:38 604.3 Electrical system hazards.Where it is found that the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service,improper fusing,insufficient receptacle and lighting outlets, improper wiring or installation,deterioration or damage,or for similar reasons,the code official shall require the defects to be corrected to eliminate the hazard. BARRY STRATTON-01/26/2022 @ 09:38 305.3 Interior surfaces. Interior surfaces,including windows and doors,shall be maintained in good,clean and sanitary condition.Peeling,chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. BARRY STRATTON-01/26/2022 @ 09:38 304.7 Roofs and drainage.The roof and flashing shall be sound,tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains,gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a public nuisance. Leak in bathroom ceiling. BARRY STRATTON-01/26/2022 @ 09:38 304.15 Doors. Exterior doors,door assemblies,operator systems if provided,and hardware shall be maintained in good condition. Locks at all entrances to dwelling units and sleeping units shall tightly secure the door. Locks on means of egress doors shall be in accordance with Section 702.3.Trim around door needs repaired. Printed on 01/266/20222 09:40 Page 3 of 4 ° ` GENERAL NOTES EARRYSTRAlTON 01/26/2022@0939 106.4 Violation penalties.Any person who shall violate a provision of this code,or fail to comply therewith,or with any of the requirements thereof, shall beprosecuted within the limits provided by state or local laws. Each day that a violation continues after due notice has been served shall be deemed a separate offense. mExNSPcCr;mNmwTE UJ/23/ZO22 CONTACT SIGNATURE Quality Concrete Signed on:01/Z6/J02Z@O0:39 INSPECTOR SIGNATURE axRRYSTRAJTON Signed on:O1/ZO/3U22@09:39 � QUESTIONS ABOUT YOUR INSPECTION? eARRYSTRATTl)N Uarry.stratton@water|oo'ia.org (319)231'8147 Printed""o,/z&zozz o*"m Page 4or*