HomeMy WebLinkAbout314 RANDOLPH ST (2) 1-66j4
WATERLOO FIRE RESCUE (P tfdkp
INSPECTNNV REPORT
ADE 314 RANTMXPII ST,314 H ST,WATERLOO IA 30701d /414
DETAILS
Inspection Date:01/26/2022 1 Inspection Type: Rental Inspection I Inspection Number:7164 I Shift: IA I Station: N/A 1
Unit: N/A Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$50.00 I, (
A—1-44Si)
STATUS CODE DESCRIPTION
FAIL 1018.1 -General Aisles and aisle accessways serving as a portion of the exit access in the means of
egress system shall comply with the requirements of this section.Aisles or aisle
accessways shall be provided from all occupied portions of the exit access that
contain seats,tables,furnishings,displays and similar fixtures or equipment.The
minimum width or required capacity of aisles shall be unobstructed. Exception:
Encroachments complying with Section 1005.7.
Inspector:BARRY STRATTON-Comments:Fire escape still not corrected. Fire Escape
is missing stairs,handrails not capable of preforming its intended function,and will
support its intended load.Fire Escape also needs to be re-certified.
FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector:BARRY STRATTON-Comments:Fire Escape
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector:BARRY STRATTON-Comments:Unit#104 had electrical issues that had
not been repaired by former owner.
FAIL 703.2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with
NFPA 80.Where allowed by the fire code official,the application of field-applied labels
associated with the maintenance of opening protectives shall follow the
requirements of the approved third-party certification organization accredited for
listing the opening protective. Fire doors and smoke barrier doors shall not be
blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced
promptly whenever fused or damaged. Fire door assemblies shall not be modified.
Inspector:BARRY STRATTON-Comments:
Printed on 01/26/2022 z.p09:27
Page 1 of 4
STATUS CODE DESCRIPTION
FAIL 901.6.1 -Standards Fire protection systems shall be inspected,tested and maintained in accordance with
the referenced standards listed in Table.
Inspector:BARRY STRATTON-Comments:Sprinkler has deficiencies that have not
been corrected since February 2021. Have sprinkler maintained and repaired.
Painted heads,wrench missing,&FBF has failed.Corrections still not done.Sprinkler
deficiencies shall be corrected ASAP.Corrections still not done.This listed address
shall be vacated until corrections can be made. Fire Marshal has been notified. Since
the fire protections is not in compliance and court order has not been corrected this
building shall be vacated until building has been brought up to code.Sprinkler
system still not repaired.
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments:Shower heads in both bathrooms need
replaced.Ceiling in living room has peeling paint and drywall tape failure.Ceiling in
living room has peeling paint and drywall tape failure.Front door jamb needs
replaced door does not fit reasonably in jamb.Unit#104 corrections not completed
by former owner.
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector:BARRY STRATTON-Comments:Bath exhaust fan need replaced on 1st floor
bathroom. Former owner did not replace fan
GENERAL NOTES
BARRY STRATTON-01/26/2022 @ 09:24 304.15 Doors. Exterior doors,door assemblies,operator systems if provided,and
hardware shall be maintained in good condition. Locks at all entrances to dwelling
units and sleeping units shall tightly secure the door.Locks on means of egress doors
shall be in accordance with Section 702.3.
BARRY STRATTON-01/26/2022 @ 09:24 403.2 Bathrooms and toilet rooms. Every bathroom and toilet room shall comply with
the ventilation requirements for habitable spaces as required by Section 403.1,except
that a window shall not be required in such spaces equipped with a mechanical
ventilation system.Air exhausted by a mechanical ventilation system from a bathroom
or toilet room shall discharge to the outdoors and shall not be recirculated.
BARRY STRATTON-01/26/2022 @ 09:24 504.1 General.Plumbing fixtures shall be properly installed and maintained in working
order,and shall be kept free from obstructions,leaks and defects and be capable of
performing the function for which such plumbing fixtures are designed.Plumbing
fixtures shall be maintained in a safe,sanitary and functional condition.
Printed on 01/2632022 009:27
Page 2 of 4
GENERAL NOTES
BARRY STRATTON-01/26/2022 @ 09:24 603.1 Mechanical appliances. Mechanical appliances,fireplaces,solid fuel-burning
appliances,cooking appliances and water heating appliances shall be properly
installed and maintained in a safe working condition,and shall be capable of
performing the intended function.
BARRY STRATTON-01/26/2022 @ 09:24 604.3 Electrical system hazards.Where it is found that the electrical system in a
structure constitutes a hazard to the occupants or the structure by reason of
inadequate service,improper fusing,insufficient receptacle and lighting outlets,
improper wiring or installation,deterioration or damage,or for similar reasons,the
code official shall require the defects to be corrected to eliminate the hazard.604.3.1
Abatement of electrical hazards associated with water exposure.The provisions of this
section shall govern the repair and replacement of electrical systems and equipment
that have been exposed to water
BARRY STRATTON 01/26/2022 @ 09:25 704.1.1 Automatic sprinkler systems. Inspection,testing and maintenance of automatic
sprinkler systems shall be in accordance with NFPA 25.
BARRY STRATTON-01/26/2022 @ 09:25 704.1 General.Systems,devices and equipment to detect a fire,actuate an alarm,or
suppress or control a fire or any combination thereof shall be maintained in an
operable condition at all times in accordance with the International Fire Code.
BARRY STRATTON-01/26/2022 @ 09:25 IFC 1104.16.7:Maintenance of fire escape stairways shall be maintained in good
working order.
BARRY STRATTON-01/26/2022 @ 09:25 All fire escapes shall be examined and/or tested and certified every five years by a
design professional or others acceptable who will then submit an affidavit city official.
BARRY STRATTON-01/26/2022 @ 09:26 107.6 Transfer of ownership.It shall be unlawful for the owner of any dwelling unit or
structure who has received a compliance order or upon whom a notice of violation has
been served to sell,transfer,mortgage,lease or otherwise dispose of such dwelling
unit or structure to another until the provisions of the compliance order or notice of
violation have been complied with,or until such owner or the owner's authorized
agent shall first furnish the grantee,transferee, mortgagee or lessee a true copy of any
compliance order or notice of violation issued by the code official and shall furnish to
the code official a signed and notarized statement from the grantee,transferee,
mortgagee or lessee,acknowledging the receipt of such compliance order or notice of
violation and fully accepting the responsibility without condition for making the
corrections or repairs required by such compliance order or notice of violation.
Former owner failed to make required corrections.
1tW1NSPECTION DATE
02/23/2022
Printed on 01 2E/2022 g•03.27
Page 3 of 4
CONTACT SIGNATURE
Prairie Rapids Apartments LLC j-PI\N\
�
Signed on:01/26/2022 @ 09:26 f
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:01/26/2022 @ 09:27