WATERLOO FIRE RESCUE INSP TION REPORT411
%\\ C
17FLOWER ,WATERLOO rAS0701 C .� c)to 13
DETAILS
Inspection Date:02/01/2022 Inspection Type: Rental Inspection 1 Inspection Number:7184 I Shift: N I Station: N/A
Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$50.00 - 1411 4-,Ar,
STATUS CODE DESCRIPTION
FAIL 1013.3-Illumination Exit signs shall be internally or externally illuminated. Exception:Tactile signs required
by Section 1013.4 need not be provided with illumination.
Inspector:BARRY STRATTON-Comments:Egress/exit lights still not working
FAIL 1025.5-Illumination Where photoluminescent exit path markings are installed,they shall be provided with
not less than 1 footcandle(11 lux)of illumination for not less than 60 minutes prior to
periods when the building is occupied and continuously during the building
occupancy.
Inspector:BARRY STRATTON-Comments:Lights still not working in hallways.Several
lights plugged into extension cords running under doors form apartments and some
wired into baseboard heaters.
FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector:BARRY STRATTON-Comments:
FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector:BARRY STRATTON-Comments:Globes are needed on all lights. Lights need
to be in working condition.Outlets in unit 2 need repaired since upper portion does
not work. Extension cords wired into baseboard heaters need removed.Shop lights
from#2 hanging in entry way. Extension cord from unit#4 to#3.
Printed on 02/01/2022 tg=13:43
Page 1 of 5
•
STATUS CODE DESCRIPTION
FAIL 703.2-Opening protectives Opening protectives shall be maintained in an operative condition in accordance with
NFPA 80.Where allowed by the fire code official,the application of field-applied labels
associated with the maintenance of opening protectives shall follow the
requirements of the approved third-party certification organization accredited for
listing the opening protective. Fire doors and smoke barrier doors shall not be
blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced
promptly whenever fused or damaged.Fire door assemblies shall not be modified.
Inspector:BARRY STRATTON-Comments:Fire doors missing hardware and doors
held in open position.
FAIL 901.6-Inspection,testing and Fire detection,alarm,and extinguishing systems,mechanical smoke exhaust
maintenance systems,and smoke and heat vents shall be maintained in an operative condition at
all times,and shall be replaced or repaired where defective. Nonrequired fire
protection systems and equipment shall be inspected,tested and maintained or
removed.
Inspector:BARRY STRATTON-Comments:Alarm still has not been tested and had
maintenance.
FAIL 901.6.1 -Standards Fire protection systems shall be inspected,tested and maintained in accordance with
the referenced standards listed in Table
Inspector: BARRY STRATTON-Comments:Alarm
FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new
and existing Group A,B,E, F, H, I, M,R-1,R-2, R-4 and S occupancies. Exception: In
Group R-2 occupancies, portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a portable
fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm)
of commercial cooking equipment.3.In areas where flammable or combustible
liquids are stored, used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1.5.
Where required by the sections indicated in Table 906.1.6.Special-hazard areas,
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector: BARRY STRATTON-Comments:Still Need fire extinguishers for building
FAR. 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be
multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72.
alarms
Inspector:BARRY STRATTON-Comments:Smoke detectors missing unit 2 needs
smoke detectors in each bedroom and outside of the bedroom.All apartments need
to meet this requirement.
Printed an 02/01/2022 L 13:43
Page 2 of 5
STATUS CODE DESCRIPTION
FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may
include boilers,heating equipment,elevator,moving stairways,electrical wiring,and
flammable liquid containers.(IPMC 108.1.2)
Inspector:BARRY STRATTON-Comments:No permits or inspections for the sanitary
water system work preformed at listed address. No excavation permit was obtained
for ROW work.
FAIL R3-Unfit for Human Is the structure found to be fit for human occupancy according to the code?(IPMC
Occupancy 108.1.3)
Inspector: BARRY STRATTON-Comments:Building is lacking maintenance. 108.1.3
Structure unfit for human occupancy.A structure is unfit for human occupancy
whenever the code official finds that such structure is unsafe,unlawful or,because of
the degree to which the structure is in disrepair or lacks maintenance,is insanitary,
vermin or rat infested,contains filth and contamination,or lacks ventilation,
illumination,sanitary or heating facilities or other essential equipment required by
this code,or because the location of the structure constitutes a hazard to the
occupants of the structure or to the public.Court Order to vacate building.
FAIL R4- Exterior Property Areas Is the exterior property area maintained in a clean,safe,and sanitary condition?This
includes grading and drainage,sidewalks and driveways,weeds,and pest
infestations.(IPMC 302)
Inspector:BARRY STRATTON-Comments:Debris all over the rear of the property.
FAIL R5- Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and
sanitary state?(IPMC 304)
Inspector:BARRY STRATTON-Comments:Concrete block still not corrected
FAIL R6-Interior Structure Has the interior of the structure and equipment inside been maintained in good
repair,structurally sound,and in a sanitary condition?(IPMC 305)
Inspector:BARRY STRATTON-Comments:Still need new kitchen faucet in unit#2.
Exhaust fan in unit#2 need cover.Shower in unit#2 has peeling paint. Door jambs
and weather strip still not fixed.Windows are broken on rear of building.Owner has
never requested re-inspection to check completed work.
FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1)
Unsafe Conditions
Inspector:BARRY STRATTON-Comments:Exit/egress lights still not working,no fire
extinguishers,sanitary conditions of building
Printed on 02/01/2022 C 13:43
Page 3 of 5
►
STATUS CODE DESCRIPTION
FAIL R6.B.-Residential Heating Are dwellings provided with heating facilities capable of maintaining a room
temperature of 68F?(IPMC 602.2)
Inspector:BARRY STRATTON-Comments:Maintenance of furnaces is needed
FAIL R6.C.-Mechanical Eqiupment Are mechanical appliances properly installed and maintained in good working
condition?(IPMC 603.1)
Inspector: BARRY STRATTON-Comments:
GENERAL NOTES
BARRY STRATTON-02/01/2022 @ 13:42 Unit#2 and common areas
BARRY STRATTON-02/01/2022 @ 13:42 9-7-6:DENIAL,SUSPENSION,REVOCATION OR NONRENEWAL:A.Grounds:The licensing
officer or building official may revoke,suspend,deny or decline to renew any landlord
license issued under section 9-7-4 of this chapter or any rental registration permit
issued under section 9-7-5 of this chapter for any of the following grounds:3. Failure to
correct deficiencies noted in notices of violation within the time specified in the notice.
REINSPECTION DATE
03/01/2022
CONTACT SIGNATURE
Dominic Tangen
Signed on:02/01/2022 @ 13:42
INSPECTOR SIGNATURE
BARRY STRATTON
Signed on:02/01/2022 @ 13:42
Printed on O2/01/2022 P 13.43