Loading...
HomeMy WebLinkAbout811 W 3RD ST WATERLOO`ERLOO FIRE RESCUE ''5 ck � INSPECTION REPORT 1 C1�\ CCA 811 W 3RD Sr,WATERLOO to 50701 C DETAILS Inspection Date:02/04/2022 [ Inspection Type: Rental Inspection I Inspection Number:7189 I Shi : N/A I Station: N/A I Unit: N/A I Lead Inspector:BARRY STRATTON I Other Inspectors: N/A I Fee:$50.00 .1Ati )J STATUS CODE DESCRIPTION FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:BARRY STRATTON-Comments:Front door still not replaced. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments:Bath fan globe hanging from fixture. FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A,B, E,F, H,I, M,R-1,R-2, R-4 and S occupancies.Exception:In Group R-2 occupancies,portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies, in accordance with Section 3315.1.5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector:BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11,6 and NFPA 72. alarms Inspector:BARRY STRATTON-Comments:Smoke detectors needed in all rooms used for sleeping purposes. Panted an 02/04/2022 It 10:12 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 915.1 -General Carbon monoxide detection shall be installed in new buildings in accordance with Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector:BARRY STRATTON-Comments: FAIL R5-Exterior Structure Is the exterior of the structure maintained in good repair,structurally sound and sanitary state?(IPMC 304) Inspector:BARRY STRATTON-Comments:Front door and front step at entrance the rise is to tall. FAIL R6- Interior Structure Has the interior of the structure and equipment inside been maintained in good repair,structurally sound,and in a sanitary condition?(IPMC 305) Inspector:BARRY STRATTON-Comments:Front door needs replaced. Door broken and door also does not fit reasonably in jamb. Peeling paint in shower on ceiling. Back bedroom has mold growth from water damage. Removed all damaged drywall and replace. Interior doors missing. FAIL R6.A.-Interior Structure- Were any unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector:BARRY STRATTON-Comments:Security GENERAL NOTES BARRY STRATTON-02/04/2022 @ 10:10 Unit#1 BARRY STRATTON-02/04/2022 @ 10:10 304.15 Doors. Exterior doors,door assemblies,operator systems if provided,and hardware shall be maintained in good condition.Locks at all entrances to dwelling units and sleeping units shall tightly secure the door. Locks on means of egress doors shall be in accordance with Section 702.3. BARRY STRATTON-02/04/2022 @ 10:10 305.6 Interior doors.Every interior door shall fit reasonably well within its frame and shall be capable of being opened and closed by being properly and securely attached to jambs, BARRY STRATTON-02/04/2022 @ 10:11 305.3 Interior surfaces. Interior surfaces,including windows and doors,shall be maintained in good,clean and sanitary condition.Peeling,chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. Printed an 02/04/2022 10:12 Page 2 of 3 GENERAL NOTES BARRY STRATTON-02/04/2022 @ 10:11 403,6 Mold Present In A Rental Unit.a.When mold is found to be visibly present in small amounts, it can be cleaned in a safe and sanitary manner.b.When mold is found in a rental unit and is determined to be a health risk,the building official may order that a clean air report be obtained from a mold specialist approved by the building official. BARRY STRATTON-02/04/2022 @ 10:11 304.10 Stairways,decks,porches and balconies.Every exterior stairway,deck,porch and balcony,and all appurtenances attached thereto,shall be maintained structurally sound, in good repair,with proper anchorage and capable of supporting the imposed loads. REINSPECTION DATE 03/04/2022 CONTACT SIGNATURE Adam Hunemuller / I L Signed on:02/04/2022 @ 10:11 L_ .. _ .. -".�,S. .>'-+__s�'t�S�-'ka v.F... t `: te; � ...<£Ρ,";�:z � S�.. �.i �e e t IfSPFCTOR SIGNATURE � .h -��'�.r-..ts:°a�e .. BARRY STRATTON Signed on:02/04/2022 @ 10:11 QUESTIONS ABOUT YOUR INSPECTION? 0�� rm BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Printed on 02/04/2022 C.10:12 Page 3 of 3