HomeMy WebLinkAbout811 W 3RD ST (2) WATERLOO FIRE RESCUE � - ottz, INSPECTION REPORT 8;r 11 W 3RD St WATERLOO IA 50701 \ cukbA �;' DETAILS 5 r3 inspection Date:03/04/2022 I Inspection Type: Rental Inspection I Inspection Number:7328 I Shift: N/A I Station: N/A Unit: N/A Lead Inspector:BARRY STRATTON I Other Inspectors: N/A Fee:$50.00 9�14)� 1is ° STATUS CODE DESCRIPTION FAIL 1031.2-Reliability Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:BARRY STRATTON-Comments:Front door replaced but door hardware not installed to code.Only dead bolt installed in lock set and no door knob assembly in door. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector:BARRY STRATTON-Comments:Bath fan FAIL 906.1 -Where required Portable fire extinguishers shall be installed in all of the following locations: 1.In new and existing Group A,B,E, F, H, I, M,R-1,R-2, R-4 and S occupancies. Exception: In Group R-2 occupancies, portable fire extinguishers shall be required only in locations specified in Items 2 through 6 where each dwelling unit is provided with a portable fire extinguisher having a minimum rating of 1-A:10-B:C.2.Within 30 feet(9144 mm) of commercial cooking equipment.3. In areas where flammable or combustible liquids are stored,used or dispensed.4.On each floor of structures under construction,except Group R-3 occupancies,in accordance with Section 3315.1. 5. Where required by the sections indicated in Table 906.1.6.Special-hazard areas, including but not limited to laboratories,computer rooms and generator rooms, where required by the fire code official. Inspector:BARRY STRATTON-Comments: FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector:BARRY STRATTON-Comments: Printed on 03/04,2022 0 11:51 Page 1 of 3 . ' STATUS CODE ' DESCRIPTION ` FAIL 915.1 Genera} Cat-bon monoxide detection shall be installed in new buildings in accordance with Sections 015.1.1 through 915.6. Carbon monoxide detection shall be installed in existing buildings in accordance with Section 1103.9. Inspector: 8ARRv STRATTOm Comments: FAIL RS Exterior Structure Is the exterior of the srructure maintained in good repair'szructuraUy snund and sanitary state?(|P/N[304) Inspector: BARRYSTRATT0N Comments: Front door and front step at entrance the rise is to tall. FAIL RG Interior Structure Has the interior of the suuoure and equipment inside been maintained in good repair'structurally sound' and in a sanitary condition!(|prNC 305) Inspector: 8ARRY STRxTTOw Comments: Front door needs replaced. Door broken and doora|so does not fit reasonably in jamb. Peeling paint in shower on ceiling. Back bedroom has mold growth from water damage. Removed all damaged drywall and replace. Interior doors missing. FAIL R0.x. Interior Structure- Were any Unsafe conditions noted during the interior inspection?(IPMC 305.1.1) Unsafe Conditions Inspector: BARRYSTR/TTON Comments:Security GENERAL NOTES ' 8ARRY STRAlTON 03/04/2822 @ 1 1:47 Un|c# 1 BARRv STRATT0N 82/04/2822 @ 11:47 304.15 Doors. Exterior doors' door assemb|ies, operator systenns if provided, and hardware shall be maintained in good condition. Locks at all entrances to dwelling units and sleeping units shall tightly secure the door. Locks on means of egress doors shall be in accordance with Section 702.3. BARRYSTRATT0m 03/04/2022 @ 1 1:47 305.0 Interior doors. Every interior door shall fit reasonably well within its frame and shall be capable of being opened and closed by being properly and securely attached to jambs, 8ARRvSTRA7TON 03/04/2022 @o 11:47 305.3 Interior Surfaces, Interior surfaces,including windows and doors,shall be maintained in good,cleat)and sanitary condition. Peeling,chipping'flaking o/'abraded paint shall be repaired, removed or covered, Cracked or loose plaster,decayed wood and other defective surface conditions shall he corrected. p,/".°""noy,owzmz2'm``.s` Paoazuro s _ GENERAL NOTES BARRY STRATTON-03/04/2022 @ 11:47 403.6 Mold Present In A Rental Unit.a.When mold is found to be visibly present in small amounts, it can be cleaned in a safe and sanitary manner. b.When mold is found in a rental unit and is determined to be a health risk,the building official may order that a clean air report be obtained from a mold specialist approved by the building official. BARRY STRATTON-03/04/2022 @ 11:47 304.10 Stairways,decks,porches and balconies. Every exterior stairway,deck, porch and balcony,and all appurtenances attached thereto,shall be maintained structurally sound, in good repair,with proper anchorage and capable of supporting the imposed loads. BARRY STRATTON-03/04/2022 @ 11:50 702.3 Locked doors. Means of egress doors shall be readily openable from the side from which egress is to be made without the need for keys, special knowledge or effort, except where the door hardware conforms to that permitted by the International Building Code. Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. REINSPECTION DATE 04/04/2022 CONTACT SIGNATURE Adam Hunemuller -A6,.,_ Signed on:03/04/2022 @ 11:51 INSPECTOR SIGNATURE BARRY STRATTON Signed on:03/04/2022 @ 11:51 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 P-nced on 03l004 2022 i 11 Page 3 of 3