Loading...
HomeMy WebLinkAbout2715 ST FRANCIS DR (2) r ) , 1 CISc-QQD WATERLOO FIRE RESCUE 40 e\ Dc'D3,,i.EN oo INSPECTION REPORT il i , 'k RE WILDWOOD TOWNHOUSES UNIT 2715,2715 ST FRANCIS DR, WATERLOO IA 50702 ft.) DETAILS Inspection Date:03/16/2022 ( Inspection Type: Rental Inspection I Inspection Number:7390 I S ift: N/A I Station: N/A Unit: N/A ; Lead Inspector:BARRY STRATTON I Other Inspectors: N/A j Fee:$50.00 ./2/ _zip/ / � 75/#01 STATUS CODE DESCRIPTION FAIL 505.1 -Address identification New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property.Address identification characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 1/2(12.7 mm). Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way, a monument,pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector: BARRY STRATTON-Comments:Still no listed address displayed for listed apartment. FAIL 605.1 -Abatement of Identified electrical hazards shall be abated. Identified hazardous electrical conditions electrical hazards in permanent wiring shall be brought to the attention of the responsible code official. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. Inspector: BARRY STRATTON-Comments:Electrical switches with damage need replaced.Switches have sparked and caused damage to walls. Need licensed electrician to make repairs. FAIL 907.2.11 -Single-and Listed single-and multiple-station smoke alarms complying with UL 217 shall be multiple-station smoke installed in accordance with Sections 907.2.11.1 through 907.2.11.6 and NFPA 72. alarms Inspector: BARRY STRATTON-Comments:Ensure detectors are installed to meet city rental code. FAIL R2-Unsafe Equipment Was the presence of unsafe equipment noted during the inspection?Equipment may include boilers,heating equipment,elevator, moving stairways,electrical wiring,and flammable liquid containers.(IPMC 108.1.2) Inspector: BARRY STRATTON-Comments:Hot water heater Printed an 03/16/2022 4.12:23 Page 1 of 3 � ^ S»AY0S CODE D8mmomIPqmON FAIL RS' Exterior Structure Is the exterior of the structure maintained in good repair, structurally sound and sanitary oate?(|PKx[ 304) Inspector: BARRvSTRATTON Comments: Front steps need replaced. handrai(ingnot attached to steps and not capable of preforming intended function. Need new handrail installed on front steps.(Sti|| not done) FAIL Rh.L Mechanical Eqiupmenr Are mechanical appliances properly installed and maintained in good working condition?(IP/N[603.1) Inspector: 8ARRYSTRATTON Comments:Hot water heater not providing hot water, 6mNfuA8NOnES aARRYSTRATT0N 03/16/2022@12:21 304.3 Premises identification. Buildings shall have approved address numbers placed in a position to be plainly legible and visible from the street or road fronting the property.These numbers shall contrast with their background.Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be not less than 4 inches(1O2 nim)in height with a minimum stroke width of0.S inch(12.7mm). 8ARRYSTRATTON 03/16/2022@ 12:21 ]04.10 Stairways,decks,porches and balconies. Every exterior stairway,deck,porch and balcony,and all appurtenances attached thereto,shall be maintained structurally sound' in good repair'with proper anchorage and capable of supporting the imposed loads. BARevSTRAl7UN 03/16/2022@ 12:21 304.12 Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition. BARRv STRATTOm 03/16/2022 @v 12:22 109.4Vio|ation penalties.Any person who shall violate a provision of this code,or fail to comply therewith,or with any of the requirements thereof,shall be prosecuted within the limits provided by state or local laws, Each clay that a violation continues after due notice has been served shall be deemed a separate offense. xE/mSPEcr/Om omrm O4/14/2O22 Printed""oa/`6/zvzct's�'`zz, Page zoro ~^ CONTACT SIGNATURE UNIVERSAL ACCESS MORT MIDWEST LL V\ Signed on:03/16/2022 @ 12:22 INSPECTOR SIGNATURE BARRY STRATTON Signed on:03/16/2022 @ 12:22 QUESTIONS ABOUT YOUR INSPECTION? BARRY STRATTON barry.stratton@waterloo-ia.org (319)231-9147 Prnted on:Z. :122 kg:12 2.3 Page 3 of 3