INSPECTION REPORT
MARICU SANCHEZ SINGLE FAMIL0'RENTAL,217 E 1ST S�W�� jA S���
---�'
Elf TAILS ` ^
Inspection Date:03/1U/20J2 | Inspection Type:Rental Inspection | Inspection Number:7 hi �
Unit: N/A Lead Inspector:8ARRYSTR/TTON I Other Inspectors: N/A 11 Fee:$S0.00
SYmYUS CODm of-ScItIPTImnN
FAIL 605.1 Abacemientof Identified electrical hazards shall be abated. Identified hazardous electrical conditions
electrical hazards in permanent wiring shall be brought to the attention of the responsible code official.
Electrical wiring,devices,appliances and other equipment that is modified or
damaged and constitutes an electrical shock or fire hazard shall not be used.
Inspector:BARRY STRATTON-Comments:Electric system is not grounded.SEU Cable
on house needs replaced.Service entrance box is detached from house.Outlets ill
unit have bad grounds, Need approved covers on all outlets and switches,Contact
licensed professional to make electrical corrections.Electric set-vice on exterior of
house still not corrected.
FAIL 90e.1 vvhe,e,equired Portable fire extinguishers shall be installed in all of the following locations: 1. In new
and existing Group/\8' E.F, H.|'xN.R,1'R'2' R-4 and Soccupancies. Exception:In
Group R-2 occupancies,portable fire extinguishers shall be required only in locations
specified in Items 2 through 6 where each dwelling unit is provided with a pot-table
fire extinguisher having a minimum rating of1`A: 10'8:C.2.Within]O feet(9144mm)
of commercial cooking equipment.2. In areas where flammable orcombustible
liquids are stored, used or dispensed.4.On each floor of structures under
construction,except Group R-3 occupancies, in accordance with Section 3315.1.5.
Where required by the sections indicated in Table 906.1.6. Special-hazard areas'
including but not limited to laboratories,computer rooms and generator rooms,
where required by the fire code official.
Inspector: BAKRYSTR/gT0N Comments:
FAIL 907.2.11 Single-and Listed single-and multiple-station smoke alarms complying with UL217shall be
mu|tip|e'srationsmoke installed in accordance with Sections 007.2.11.1 through 007.2.11.6 and NFPA7Z.
alarms
Inspector: BARRYSTRATTUN Comments:Smoke detectors need installed tocode
FAIL 915.1 General Carbon monoxide detection shall be installed in new buildings in accordance with
Sections 915.1.1 through 915.6.Carbon monoxide detection shall be installed in
existing buildings in accordance with Section 11O3.Q.
Inspector: BAKRYSTRATT0N Comments:
Printed""oo/`wuo2z��s�
pmoe1oro
STATUS CODE DeSCa/Pr/mm '
FAIL x5 Exterior Szruccure |s the exterior ofthe structure maintained in good repair, structurally sound and
sanitary state?(|PM{3O4)
Inspector:BARRYSTRATTUN Comments:Electrical set-vice box on house needs
replaced.SEU cable needs replaced.
FAIL RG mteriorSoucture Has the interior of the structure and equipment inside been maintained in good
repair, structurally sound,and ina sanitary condition?(|p/W[3O5)
|nspeoor:8ARRY STR/gTON-Comments:Ceiling in living room damaged from water
leak. Peeling paint needs corrected.
GENERAL NOTES
8ARRY STRATTON 03/10/2022 @ 08:53 9'7-4 0'7'5:2822 Rental registration is needed for all rental units.
BARRYSTRATTON 03/10/2022@08:54 109.4 Violation penalties.Any person who shall violate a provision of this code,or fail
to comply therewith,or with any of the requirenients thereof,shall be prosecuted
within the limits provided by state or local laws. Each day that a violation continues
after due notice has been served shall be deemed a separate offense.
AmxNSPEC|mOmDwrE
o4/U7/2O22
CONTACT SIGNATURE
K4ari|uSanchcz
Signed nn'0]/10/�O22(�U8'S4
' '
INSPECTOR SIGNATURE
BARRYsTRATTON
Signed on:O3/10/2022@08:54